Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance L 125 kHz/ 10 mA 10 H 10% Inductance L 125 kHz/ 10 mA 10 H 10% Q-Factor Q 125 kHz/ 10 mA 220 typ. Q-Factor Q 125 kHz/ 10 mA 220 typ. O 2,0 I Rated Current DC T = 40 K 9 A max. R DC 1 2 V = 20 V Power Capability P 150 W typ. DC DC Resistance R 20 C 28 m typ. 5,0 min. DC R O 50,0 1,0 DC Resistance 20 C 28 m typ. 46,0 2,0 DC R DC Resistance 20 C 30 m max. DC DC Resistance R 20 C 30 m max. DC f Self Resonant Frequency 11 MHz 10,0 2,0 res f Self Resonant Frequency 11 MHz res 2 1 6,0 ref. General Information: Storage Conditions (in original < < RH packaging) Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 1:1,25 Product Marking: Marking 760308101141 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CSo 001.000 2017-07-31 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Transmitter Coil Max-Eyth-Str. 1 760308101141 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 50 x 5 mm eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 5,0 max. 12,0 ref.Typical Inductance vs. Current Characteristics: Typical Inductance vs. Frequency Characteristics: 12.0 100 10.0 8.0 10 6.0 4.0 2.0 1 10 100 1000 10000 0.0 0.0 4.0 8.0 12.0 16.0 20.0 Frequency kHz Current A CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CSo 001.000 2017-07-31 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Transmitter Coil Max-Eyth-Str. 1 760308101141 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 50 x 5 mm eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Inductance H