Dimensions: mm Recommended Hole Pattern: mm Electrical Properties: Value sectional drawing A-A Properties Test conditions Unit Tol. 1 2 B 125 kHz/ 10 mA Inductance L 8.8 1.4 H 10% 13.56 MHz 44,0 0,5 25,0 2,0 O 1,0 125 kHz/ 10 mA 1 23 4 Q-Factor Q 30 47 typ. 13.56 MHz Copper Coil 4,0 min. Rated Current I T = 40 K 2.6 5 A max. R 2,0 ref. Saturation Current I 5 5 A typ. SAT 5,0 2,0 2,0 min. DC Resistance R 20 C 220 100 m max. DC 1 DC Resistance R 20 C 190 80 m typ. DC 2 Self Resonant Frequency f 22 16 MHz 3 res 4 A A Scale - 1:1 Copper Coil Schematic: Copper Coil PET detail B Glue PET Ferrite General Information: PET Adhesive Tape L1 It is recommended that the temperature of the component does not exceed +105C under worst Release Paper case conditions 1 2 Operating Temperature -20 up to +105 C Storage Conditions (in original L2 < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 3 4 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 1:1 Product Marking: Marking 760308103305 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CSo 001.005 2019-05-20 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Receiver Coil Max-Eyth-Str. 1 760308103305 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 4544 eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 0,72 0,3 45,0 0,5Typical Inductance vs. Current Characteristics: Typical Inductance vs. Frequency Characteristics: 12.0 100 11.0 10.0 9.0 8.0 7.0 10 6.0 5.0 4.0 3.0 2.0 1.0 1 10 100 1000 10000 100000 0.0 0.0 1.0 2.0 3.0 4.0 5.0 Frequency kHz Current A Lwpc Lnfc Lwpc Lnfc CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CSo 001.005 2019-05-20 DIN ISO 2768-1m DESCRIPTION WE-WPCC Wireless Power Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Transfer Receiver Coil Max-Eyth-Str. 1 760308103305 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 4544 eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Inductance H