Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance L 100 kHz/ 100 mV 1310 H 10% 6 7 Turns Ratio n N1:N2:N3:N4 140 : 22 : 6 : 16 3% 1,7 Saturation Current I L/L < 20 % 0.8 A typ. SAT 1 12 DC Resistance 1 R N1/ 20 C 3000 m max. DC 1 DC Resistance 2 R N2/ 20 C 450 m max. DC 2 1 12 DC Resistance 3 R N3/ 20 C 25 m max. DC 3 DC Resistance 4 R N4/ 20 C 400 m max. 14,84 ref. DC 4 6 7 Leakage Inductance L 100 kHz/ 100 mV 35 H max. S Insulation Test Voltage V N1,4 => N2,3 4000 V (AC) 24,53 T 25,81 ref. 20,6 0,2 Certification: Scale - 1,5:1 RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Schematic: Halogen Free Conform JEDEC JS709B 9 1 0,7 0,05 r 0,1 General Information: N1 N2 Operating Temperature -40 up to +125 C Storage Conditions (in original < 40 C < 75 % RH packaging) 7 2 12 3,4 Storage Conditions (for single -20 up to +60 C parts) Moisture Sensitivity Level (MSL) 1 N4 N3 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently 11 5,6 Designed to comply with the following requirements as defined by IEC61558-2-16 Reinforced insulation for a working voltage of 375 V Scale - 1,5:1 RMS Product Marking: 760871543 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION Marking YY WW XX METHOD (year - week - internal code) CHC 001.006 2020-09-24 DIN ISO 2768-1m DESCRIPTION WE-UOST Universal Offline Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Standard Transformers Max-Eyth-Str. 1 760871543 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com EE16/8/5 eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 16,6 0,6 0,4 0,05 2,54 0,1 13,5 0,5 1,17 5x 2,54Typical Application: Typical Inductance vs. Current Characteristics: Properties Value Unit 1400 Input Voltage V 85 - 265 V (AC) in Output Voltage 1 V 24 V Out1 Output Current 1 I 0.3 A Out1 1200 Output Voltage 2 V 5 V Out2 Output Current 2 I 1.15 A Out2 Auxiliary Voltage V 14 V aux Switching Frequency f 60 - 150 kHz switch 1000 Input: N1 Output 1: N2 + N3 Output 2: N3 Auxiliary: N4 800 600 400 200 0 0 0.5 1 1.5 2 Current A CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD CHC 001.006 2020-09-24 DIN ISO 2768-1m DESCRIPTION WE-UOST Universal Offline Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Standard Transformers Max-Eyth-Str. 1 760871543 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com EE16/8/5 eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H