Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Inductance L 100 kHz/ 250 mV 1000 H 20% 5,4 Rated Current I T = 40 K 0.72 A max. R Saturation Current I L/L < 10 % 0.9 A typ. SAT DC Resistance R 20 C 1200 m typ. DC DC Resistance R 20 C 1400 m max. DC Self Resonant Frequency f 1.2 MHz typ. res Operating Voltage V 400 V max. 5,0 0,2 Certification: no sensitive traces underneath the component RoHS Approval Compliant 2011/65/EU&2015/863 12,0 0,5 REACh Approval Conform or declared (EC)1907/2006 Scale - 2:1 Halogen Free Conform JEDEC JS709B Schematic: General Information: It is recommended that the temperature of the component does not exceed +125 C under worst case conditions Ambient Temperature (referring -40 up to +85 C to I ) R Operating Temperature -40 up to +125 C Storage Conditions (in original < 40 C < 75 % RH packaging) Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Scale - 2:1 400 VDC surge proof according WE-STD 1516 Product Marking: Start of Winding CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD Marking 102 (Inductance Code) ALa 001.003 2019-05-06 DIN ISO 2768-1m DESCRIPTION WE-PD HV SMT Power Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions (High Voltage) Max-Eyth-Str. 1 7687709102 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 1210 eiSos Valid 1/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 12,0 0,5 7,5 0,3 10,5 max. 2,9 12,8Typical Inductance vs. Current Characteristics: Typical Impedance Characteristics: 1,200 100000 1,000 10000 800 1000 600 100 400 10 200 1 0.001 0.01 0.1 1 10 0 Frequency MHz 0.0 0.5 1.0 1.5 2.0 2.5 Current A Z CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ALa 001.003 2019-05-06 DIN ISO 2768-1m DESCRIPTION WE-PD HV SMT Power Inductor Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions (High Voltage) Max-Eyth-Str. 1 7687709102 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 1210 eiSos Valid 2/6 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Inductance H Impedance