Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. DC Operating Voltage V 78 V max. DC 9,3 (Reverse) Breakdown Voltage V 1 mA 91.25 V 5% BR 4,7 2,3 Clamping Voltage V I 126 V max. Clamp PEAK (Reverse) Peak Pulse Current I 10/1000 s 11.9 A max. Peak (Forward) Peak Pulse Current 1) I 200 A max. Peak Leakage Current I V 1 A max. Leak DC Steady State Power Dissipation P T = 50 C 6.5 W max. Diss A 1,14 0,38 Power Dissipation 2) P 10/1000 s 1500 W max. Diss 7,94 0,19 Polarity Unidirectional 1) 8.3 ms single half-sine wave or equivalent square wave. Duty cycle = 4 pulses per minute 2) Mounted on 5.0 mm x 5.0 mm (0.03 mm thick) Copper Pads to each terminal Scale - 4:1 Certification: 6,86 0,25 RoHS Approval Compliant 2011/65/EU&2015/863 Schematic: REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B Halogen Free Conform IEC 61249-2-21 Cathode UL Approval UL497B: E478010, UL 1449: E332875 Plastic Housing Flammability UL94 V-0 Rating General Information: It is recommended that the temperature of the component does not exceed +150C under worst case conditions Operating Temperature -65 up to +150 C Cathode Band Anode Storage Conditions (in original < 40 C < 75 % RH packaging) Scale - 4:1 Moisture Sensitivity Level (MSL) 1 Test conditions of Electrical Properties: +20 C, 33 % RH if not specified differently Product Marking: Marking GGT CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD RoD 001.001 2020-05-12 DIN ISO 2768-1m DESCRIPTION WE-TVSP Power TVS Diode Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 824540781 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com DO-214AB eiSos Valid 1/8 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 5,9 0,32 3,05 0,15 2,34 0,28 2,5 0,3 3,3Maximum Peak Pulse Power Rating Peak Pulse Power and Current Derating 100.0 100 90 80 70 10.0 60 50 40 1.0 30 20 10 0.1 0 1 10 100 1000 0 50 100 150 Pulse Width s Ambient Temperature C CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD RoD 001.001 2020-05-12 DIN ISO 2768-1m DESCRIPTION WE-TVSP Power TVS Diode Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions Max-Eyth-Str. 1 824540781 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com DO-214AB eiSos Valid 2/8 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Power kW Derating %