Dimensions: mm Recommended Land Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. 1 0.2 V , 1 kHz 10% Capacitance C RMS 3.3 nF 5% 25 C 2,8 V 1,0 Rated Voltage 100 V (DC) max. R 1 0.2 V , 1 kHz 10% Q-Factor Q RMS 1000 min. 25 C R Apply V for 120 s max. Insulation Resistance 10 G min. 0,5 0,2 ISO R Precondition for Class II MLCC measurement: Apply a preheat treatment 150 10 C for 1 hour. The measurement should be applied after 24 2 hrs the part was stored under ambient conditions. There is not any precondition necessary for Class I MLCC. 2,0 0,15 Schematic: General Information: General Purpose MLCC Ceramic Type NP0 Class I Temperature Coefficient 30 ppm/ C max. Operating Temperature -55 up to +125 C Storage Conditions 5 C up to + 35 C 10 % up to 75 % RH (in original packaging) Moisture Sensitivity Level (MSL) 1 5 sec. 250 % V Charge & Discharge Current <50 mA Dielectric Strength R Test conditions of Electrical Properties: +20 C, 35 % RH if not specified differently FIT according to separate documentation CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD PSL 002.000 2021-01-03 DIN ISO 2768-1m DESCRIPTION TECHNICAL REFERENCE NP00805332J100DFCT10000 WCAP-CSGP Ceramic Capacitors Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions 0805 Max-Eyth-Str. 1 885012007091 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 0805 eiCap Valid 1/8 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 1,25 0,1 1,25 0,1 1,3Mechanical Properties Properties Definition Adhesive Strength of Termination 0201 10 1 sec 2 N 0402 & 0603 10 1 sec 5 N > 0603 10 1 sec 10 N all 3 directions, 2 hours each 10 - 55 Hz/ Vibration Resistance min., amplitude 0.75 mm or 10 g Resistance to Solder Heat Specific Refer to Soldering Profile Certification: RoHS Approval Compliant 2011/65/EU&2015/863 REACh Approval Conform or declared (EC)1907/2006 Halogen Free Conform JEDEC JS709B Halogen Free Conform IEC 61249-2-21 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD PSL 002.000 2021-01-03 DIN ISO 2768-1m DESCRIPTION TECHNICAL REFERENCE NP00805332J100DFCT10000 WCAP-CSGP Ceramic Capacitors Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions 0805 Max-Eyth-Str. 1 885012007091 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 0805 eiCap Valid 2/8 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.