Dimensions: mm Recommended Hole Pattern: mm Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 kHz 0.2 kHz C 56 nF 10% Rated Voltage U 275 V (AC) max. R Rated Voltage U 630 V (DC) max. R Insulation Resistance 1 min 100 V (DC) R 30000 M min. ISO P Dissipation Factor 1 kHz DF 0.1 % max. Dissipation Factor 10 kHz DF 0.1 % max. Dissipation Factor 100 kHz DF 0.5 % max. p Rate of Voltage Rise dV/dt 300 V/s max. L Dielectric Strength Pin to 1 min./ +20 C 1333 V (DC) Pin Dielectric Strength Pin to 1 min./ +20 C 2000 V (AC) Case Schematic: General Information: X2-Safety Class Capacitor MKP - Metallized Polypropylene Storage Conditions 5-35 C, < 75% RH Operating Temperature -40 C up to +105 C Maxium Selfheating (Rated) 7 C Climate Category: 40/ 105/ 56/ B Test conditions of Electrical Properties: +20 C, 35 % RH if not specified differently FIT according to separate documentation Component conform to REACh and RoHS requirements and standards Only designed to be used in parallel to the mains, not approved for series applications. Properties Value Unit Tol. Pitch P 10 mm 0.5 CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD Length L 13 mm 0.5 EMC & Inductive Solutions KaS PSL DIN ISO 2768-1m Width W 5 mm 0.5 Max-Eyth-Str. 1 DESCRIPTION TECHNICAL REFERENCE 74638 Waldenburg Height H 10 mm 0.5 MX2P010563K275ACPP55004 Germany WCAP-FTX2 Film Capacitors Tel. +49 (0) 79 42 945 - 0 Pin length G 4 mm 0.5 ORDER CODE www.we-online.com Pin Diameter F 0.6 mm 0.05 890324023017CS eiSos we-online.com Pitch p 10 mm 0.5 SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE Hole Diameter f 0.9 mm 002.000 Valid 2018-03-01 eiCap 1/8 Pitch 10 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. W OF G H OfProduct Marking: Damp Heat IEC 60068 - 2 - 78 40C, 95% RH, 56 days 1st Line right Matchcode: FTX2 Temperature 5 cycles, upper and lower temperature 30 min. each, 30 sec. transfer IEC 60068 - 2 - 14 Cycles time 2nd Line right Rated Voltage: 275 V~ 3rd Line right Climate Category: 40/ 105/ 56/ B Charge/ IEC 60384 - 14 2 x UR 100 V/s Discharge Test 2nd Line left Capacitance & Tolerance Code: 563K (Basis pF) Bottom Line Certificates: ENEC, cULUS, CQC & Internal Marking Surge Test IEC 60384 - 14 2.5 kV Surge impulses Top Cover Marking P < 15 Date Code: YWW Top Cover Marking P 15 Date Code & Capacitance & Tolerance Code Certification: Properties Standard File ENEC10 by VDE IEC 60384-14 40038405 cULus UL 60384-14 / CAN/CSA - E60384-14 E345659 CQC IEC 60384-14 13001104051 Mechanical Properties: Properties Test Conditions Lead Diameter mm Force N condition Termination Robustness IEC 600668 - 2 - 21 Pull Test 0.5 to 0.8 10 min. 10 sec. 0.9 to 1.25 20 min. 10 sec. Bend Test 0.5 to 0.8 5 min. 2 cycles 0.9 to 1.25 10 min. 2 cycles Environmental Tests: Properties Standard Active IEC 60384-14 max. 24 surge pulses 2.5 kV (one pulse every 5 seconds) Flammability Passive IEC 60384-14 in combination with IEC 60381 - 1 & IEC 60695 - 11 - 5 Flammability all 3 directions, 2 hours each 10 - 55 - 10 Hz, amplitude 0.75 mm or Vibration IEC 60068 - 2 - 6 10 g CREATED CHECKED GENERAL TOLERANCE PROJECTION Wrth Elektronik eiSos GmbH & Co. KG METHOD EMC & Inductive Solutions KaS PSL DIN ISO 2768-1m Max-Eyth-Str. 1 DESCRIPTION TECHNICAL REFERENCE 74638 Waldenburg MX2P010563K275ACPP55004 Germany WCAP-FTX2 Film Capacitors Tel. +49 (0) 79 42 945 - 0 ORDER CODE www.we-online.com 890324023017CS eiSos we-online.com SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE 002.000 Valid 2018-03-01 eiCap 2/8 Pitch 10 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.