A Dimensions: mm B Recommended hole pattern: mm D1 Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 kHz 0.2 kHz C 0.2200 F 10% Rated voltage U 310 V (AC) R Isolation Resistance 1 min 100V (DC) R > 30000 M min. Iso Dissipation factor 1 kHz DF < 0.10 % max. Dissipation factor 10 kHz DF < 0.20 % max. Dissipation factor 100 kHz DF < 2.0 % max. Rate of Voltage Rise dV/ dt 160 V/ s max. C Schematic: Dielectric strength Pin to Pin 1 minute 1333 V (DC) Dielectric strength Pin to Case 1 minute 2000 V (AC) E General information: X2-Safety Class Capacitor MKP - Metallized Polypropylene Storage Conditions: 35C, <45% RH Operating Temperature: -40C to +105C Climate category: 40/ 105/ 56/ B Maximum Selfheating (rated): 7C Test conditions of Electrical Properties: 20C, 33% RH if not specified differently FIT according to separate documentation DESCRIPTION P 0.5 22.5 L 0.5 26.0 WCAP-FTXX Film Capacitors H 0.5 15.0 Wrth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions 1.3 2015-04-16 SSt PSL W 0.5 6.0 Max-Eyth-Str. 1 1.2 2014-08-14 SSt PSL 74638 Waldenburg Order.- No. PL min. 20.0 SIZE Germany 1.1 2014-05-20 SSt PSL Tel. +49 (0) 79 42 945 - 0 Pin 0.05 0.8 www.we-online.com 890334026003 A4 1.0 2014-01-22 SSt PSL d1 1.1 eiSos we-online.com REV DATE BY CHECKED Size: Pitch 22.5 mm - PL 20 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.Component Marking: D3 Mechanical Properties: Print Description Properties Test Conditions Lead diameter mm Force N condition st 1 Line right Matchcode: FTXX Termination Robustness IEC 600668 - 2 - 21 Pull Test 0.5 to 0.8 10 min. 10 sec. nd 2 Line right Rated Voltage: 310 V~ 0.9 to 1.25 20 min. 10 sec. rd 3 Line right Climate Category: 40/105/56/B Bend Test 0.5 to 0.8 5 min. 2 cycles 1st Line left Capacitance & Tolerance Code: 224K (Basis pF) 0.9 to 1.25 10 min. 2 cycles Bottom line Certificates: ENEC, cULUS, CQC & Internal Marking Top Cover Marking P < 15 Date Code: YWW D4 Environmental Tests: Top Cover Marking P 15 Date Code & Capacitance & Tolerance Code Properties Standard Active Flammability IEC 60384-14 max. 24 surge pulses 2.5 kV (one pulse every 5 seconds) D2 Approvals: Passive Flammability IEC 60384-14 in combination with IEC 60381 - 1 & IEC 60695 - 11 - 5 Properties Standard File Vibration IEC 60068 - 2 - 6 all 3 directions, 2 hours each 10 - 55 - 10 Hz, amplitude 0.75 mm or 10 g ENEC10 by VDE IEC 60384 - 14 40038405 Damp Heat IEC 60068 - 2 - 78 40C, 95% RH, 56 days cULus UL 60384 - 14 / CAN/CSA - E60384 - 14 E345659 Temperature Cycles IEC 60068 - 2 - 14 5 cycles, upper and lower temperature 30 min. each, 30 sec. transfer time CQC IEC 60384 - 14 13001104050 Charge/ Discharge Test IEC 60384 - 14 2 x U 100 V/s R Surge Test IEC 60384 - 14 2.5 kV Surge impulses DESCRIPTION WCAP-FTXX Film Capacitors Wrth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions 1.3 2015-04-16 SSt PSL Max-Eyth-Str. 1 1.2 2014-08-14 SSt PSL 74638 Waldenburg Order.- No. SIZE Germany 1.1 2014-05-20 SSt PSL Tel. +49 (0) 79 42 945 - 0 www.we-online.com 890334026003 A4 1.0 2014-01-22 SSt PSL eiSos we-online.com REV DATE BY CHECKED Size: Pitch 22.5 mm - PL 20 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.