Order L Thread Wrench Code (mm) Size Size 970050151 5 M 2,5 SW 5 970060151 6 M 2,5 SW 5 7 M 2,5 SW 5 970070151 970080151 8 M 2,5 SW 5 970090151 9 M 2,5 SW 5 970100151 10 M 2,5 SW 5 970110151 11 M 2,5 SW 5 12 M 2,5 SW 5 970120151 970050351 5 M 3 SW 5 970100351 10 M 3 SW 5 970150351 15 M 3 SW 5 970200351 20 M 3 SW 5 5 M 3 SW 5.5 970050321 970060321 6 M 3 SW 5.5 970070321 7 M 3 SW 5.5 970080321 8 M 3 SW 5.5 sectional drawing A-A 970090321 9 M 3 SW 5.5 10 M 3 SW 5.5 970100321 Ti A 970110321 11 M 3 SW 5.5 970120321 12 M 3 SW 5.5 970130321 13 M 3 SW 5.5 14 M 3 SW 5.5 970140321 15 M 3 SW 5.5 970150321 970050361 5 M 3 SW 6 970060361 6 M 3 SW 6 970070361 7 M 3 SW 6 8 M 3 SW 6 970080361 9 M 3 SW 6 970090361 970100361 10 M 3 SW 6 970110361 11 M 3 SW 6 970120361 12 M 3 SW 6 13 M 3 SW 6 970130361 14 M 3 SW 6 970140361 970150361 15 M 3 SW 6 A 970050471 5 M 4 SW 7 970080471 8 M 4 SW 7 10 M 4 SW 7 970100471 12 M 4 SW 7 970120471 970130471 13 M 4 SW 7 970150471 15 M 4 SW 7 970160471 16 M 4 SW 7 17 M 4 SW 7 970170471 18 M 4 SW 7 970180471 970200471 20 M 4 SW 7 970080481 8 M 4 SW 8 970100481 10 M 4 SW 8 12 M 4 SW 8 970120481 970150481 15 M 4 SW 8 970080581 8 M 5 SW 8 970100581 10 M 5 SW 8 970120581 12 M 5 SW 8 13 M 5 SW 8 970130581 970150581 15 M 5 SW 8 970160581 16 M 5 SW 8 970170581 17 M 5 SW 8 970180581 18 M 5 SW 8 20 M 5 SW 8 970200581 Surface coating: Gloss zinc-plated 970100611 10 M6 SW 10 CREATED CHECKED GENERAL TOLERANCE PROJECTION SCALE Wrth Elektronik eiSos GmbH & Co. KG METHOD D. Fandrey S.Klingler 5 : 1 DIN ISO 2768-1m EMC & Innductive Solutions DESCRIPTION MATERIAL Max-Eyth-Str. 1 Steel 74638 Waldenburg AsSSTII Germany Steel Spacer Stud with Metric ORDER CODE com. +49 79 42 945 - 0 970 xxx xx1 Thread, internal/internal SIZE STATUS DATE BUSINESS UNIT PAGE www.we-online.de xxx xxx xxx xxx xxx xxx Released 2015-03-09 1 /1 eiCan eiSos we-online.de This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. SW L TliOrder L Tli Thread Wrench Code (mm) (mm) Size Size 970140151 14,0 6,0 M 2,5 SW 5 970150151 15,0 6,0 M 2,5 SW 5 970160151 16,0 6,0 M 2,5 SW 5 970170151 17,0 6,0 M 2,5 SW 5 970180151 18,0 6,0 M 2,5 SW 5 970200151 20,0 6,0 M 2,5 SW 5 970220151 22,0 6,0 M 2,5 SW 5 970250151 25,0 8,0 M 2,5 SW 5 970300151 30,0 8,0 M 2,5 SW 5 970160321 16,0 6,0 M 3 SW 5,5 970170321 17,0 6,0 M 3 SW 5,5 970180321 18,0 6,0 M 3 SW 5,5 970190321 19,0 6,0 M 3 SW 5,5 970200321 20,0 6,0 M 3 SW 5,5 970210321 21,0 6,0 M 3 SW 5,5 970220321 22,0 6,0 M 3 SW 5,5 970230321 23,0 6,0 M 3 SW 5,5 sectional drawing A-A 970240321 24,0 6,0 M 3 SW 5,5 Ti1 970250321 25,0 6,0 M 3 SW 5,5 A 970270321 27,0 6,0 M 3 SW 5,5 970280321 28,0 10,0 M 3 SW 5,5 970300321 30,0 6,0 M 3 SW 5,5 970350321 35,0 6,0 M 3 SW 5,5 970400321 40,0 6,0 M 3 SW 5,5 970450321 45,0 6,0 M 3 SW 5,5 970500321 50,0 6,0 M 3 SW 5,5 970550321 55,0 6,0 M 3 SW 5,5 970600321 60,0 6,0 M 3 SW 5,5 970700321 70,0 6,0 M 3 SW 5,5 970800321 80,0 6,0 M 3 SW 5,5 970170361 17,0 6,0 M 3 SW 6 970180361 18,0 6,0 M 3 SW 6 970200361 20,0 6,0 M 3 SW 6 970220361 22,0 6,0 M 3 SW 6 970250361 25,0 6,0 M 3 SW 6 970270361 27,0 6,0 M 3 SW 6 970280361 28,0 6,0 M 3 SW 6 970300361 30,0 6,0 M 3 SW 6 970350361 35,0 6,0 M 3 SW 6 970370361 37,0 6,0 M 3 SW 6 970380361 38,0 6,0 M 3 SW 6 970400361 40,0 6,0 M 3 SW 6 970420361 42,0 6,0 M 3 SW 6 970450361 45,0 6,0 M 3 SW 6 970500361 50,0 6,0 M 3 SW 6 970550361 55,0 6,0 M 3 SW 6 970600361 60,0 6,0 M 3 SW 6 970250471 25,0 10,0 M 4 SW 7 970300471 30,0 10,0 M 4 SW 7 970350471 35,0 10,0 M 4 SW 7 Ti2 A 970400471 40,0 10,0 M 4 SW 7 970450471 45,0 10,0 M 4 SW 7 970500471 50,0 10,0 M 4 SW 7 970600471 60,0 10,0 M 4 SW 7 970700471 70,0 10,0 M 4 SW 7 970800471 80,0 10,0 M 4 SW 7 970170481 17,0 8,0 M 4 SW 8 970180481 18,0 8,0 M 4 SW 8 970200481 20,0 8,0 M 4 SW 8 970220481 22,0 8,0 M 4 SW 8 970230481 23,0 8,0 M 4 SW 8 970250481 25,0 8,0 M 4 SW 8 970270481 27,0 8,0 M 4 SW 8 970300481 30,0 8,0 M 4 SW 8 970320481 32,0 8,0 M 4 SW 8 970350481 35,0 8,0 M 4 SW 8 970400481 40,0 8,0 M 4 SW 8 970450481 45,0 8,0 M 4 SW 8 970500481 50,0 8,0 M 4 SW 8 970600481 60,0 8,0 M 4 SW 8 970950481 95,0 8,0 M 4 SW 8 970220581 22,0 10,0 M 5 SW 8 970250581 25,0 10,0 M 5 SW 8 970280581 28,0 10,0 M 5 SW 8 970300581 30,0 10,0 M 5 SW 8 970350581 35,0 10,0 M 5 SW 8 970400581 40,0 10,0 M 5 SW 8 970450581 45,0 10,0 M 5 SW 8 970500581 50,0 10,0 M 5 SW 8 970600581 60,0 11,0 M 5 SW 8 970650581 65,0 11,0 M 5 SW 8 Surface coating: Gloss zinc-plated 970400511 40,0 10,0 M5 SW10 970600611 60,0 10,0 M6 SW10 CREATED CHECKED GENERAL TOLERANCE PROJECTION SCALE Wrth Elektronik eiSos GmbH & Co. KG METHOD D. Fandrey S.Klingler 5 : 1 DIN ISO 2768-1m EMC & Innductive Solutions DESCRIPTION MATERIAL Max-Eyth-Str. 1 Steel 74638 Waldenburg AsSSTII Germany Steel Spacer Stud with Metric ORDER CODE com. +49 79 42 945 - 0 970 xxx xx1 Thread, internal/internal SIZE STATUS DATE BUSINESS UNIT PAGE www.we-online.de xxx xxx xxx xxx xxx xxx Released 2015-03-09 1 /1 eiCan eiSos we-online.de This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. SW L Tli2 Tli1