XenoEnergy Co., Ltd. 470-20, Moosong-Dong, Hwaseong-City, Kyonggi-Do, Korea 445-020 Tel: +82-31-355-3511/2, Fax: +82-31-355-3513/4 RE: Battery Storage & Depassivation Instructions XenoEnergy Lithium Thionyl Chloride Batteries have unique chemical system, so following battery storage and depassivation instructions are required. 1. Product Type: Lithium Thionyl Chloride (Li-SOCl ) Batteries, 3.6V, Non-Rechargeable 2 2. Battery Storage Guideline Li-SOCl2 batteries shall be stored in following conditions to keep the battery characteristics. - Store batteries at clean, cool (not over +30), dried (less than 30% RH) and ventilated conditions. - Store batteries in original separate trays and boxes. - Store batteries in anti-magnetic and non-conductive status. - Release batteries in first-in and first-out basis. - Do not store fresh and used batteries together. - Do not store corroded or leaked batteries with fresh batteries together. (Leaked toxic materials may damage fresh batteries.) 3. Handling Warning Li-SOCl2 batteries contain hazardous ingredients but have hermetically sealed structure, so they are not hazardous when they are used in the normal storage or usage. - Do Not Recharge, Short Circuit, Puncture, Crush, Disassemble, Heat above 100 (212), Incinerate or Expose Contents to Water. - Risk of Fire, Explosion and Severe Burn Hazard in case of abuse (mechanical, terminal and electrical) which leads to the activation of safety protection and/or the rupture of the battery container. Under abusive conditions, the battery contained materials may leak and following special exposure control and personal protection is necessary. * Do not touch corroded and leaked batteries in bare hands * Do not contact corroded and leaked batteries to the skin or body * Do not inhale or ingest leaked ingredients For more information, please kindly see Material Safety Data Sheet. XenoEnergy Co., Ltd. 470-20, Moosong-Dong, Hwaseong-City, Kyonggi-Do, Korea 445-020 Tel: +82-31-355-3511/2, Fax: +82-31-355-3513/4 4. Long Term Storage and Depassivation It is natural that Li-SOCl2 batteries have passivation (LiCl) film when they are stored for a long period without discharge and usage. We recommend that customer shall use our batteries within 6 months from the arrival. However, if it is over the storage recommended period, we suggest the following depassivation process. Storage of 6 months Depassivation is not necessary. Storage of 6 ~ 12months // 13 ~ 24 months Depassivation is recommended as follows Model Storage of 6~12months Storage of 13~24months XL(P)-050F, XL-050H 30mA, 10sec. 30mA, 30sec. XL(P)-055F 40mA, 10sec. 40mA, 30sec. XL(P)-060F, XL-060H 60mA, 10sec. 60mA, 30sec. XL-100F 60mA, 10sec. 60mA, 30sec. XL-145F 100mA, 10sec. 100mA, 30sec. XL-205F 100mA, 10sec. 100mA, 30sec. XL-210F 30mA, 10sec. 30mA, 30sec. V.12-12A