xppower.com 40 60 Watts ACS Series Low Cost Small Size Universal Input Rugged Design High MTBF International Safety Approvals Covered Versions Available Specification Input General Input Voltage 90-264 VAC (110-370 VDC) Efficiency See tables Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Input Current ACS40: 0.45 A rms at 230 VAC 500 VAC Output to Ground ACS60: 0.60 A rms at 230 VAC Switching Frequency 50-70 kHz Inrush Current Cold start at 25 C: 25 A at 115 VAC, 50 A at 230 VAC MTBF 230 kHrs per MIL-HDBK-217F Earthing Class I Environmental Output Operating Temperature 0 C to +70 C, derate from full load at +50 C to half load at +60 C. Output Voltage See table Reduce both temperatures by 10 C when Hold Up Time 8 ms typical at full load cover is fitted Line Regulation 0.5%max at full load Storage Temperature -40 C to +85 C Load Regulation 1.0% max at 10% load to full load Ripple & Noise 1% max pk-pk, 20MHz BW EMC & Safety Overvoltage Protection Typically 130% of max output Emissions FCC20780 Level B, CISPR22 (EN55022), Overcurrrent Protection 120% typical level B conducted ESD Immunity EN61000-4-2, level 3 Perf Criteria A Radiated Immunity EN61000-4-3, 10 V/m Perf Criteria A EFT/Burst EN61000-4-4, level 2 Perf Criteria A Surge EN61000-4-5, level 3 Perf Criteria A Conducted Immunity EN61000-4-6, 10 V Perf Criteria y Safety Approvals EN60950, UL1950, CSA22.2 No. 234 AC DCAC DC ACS Models and Ratings Output Output Current Model Output Power Efficiency (1) Voltage Number Nominal Peak 3.3 V 6.000 A 7.200 A 74% ACS40US03 5.0 V 6.000 A 7.200 A 78% ACS40US05 9.0 V 4.450 A 5.340 A 82% ACS40US09 12.0 V 3.340 A 4.000 A 84% ACS40US12 40 W 15.0 V 2.670 A 3.200 A 85% ACS40US15 24.0 V 1.670 A 2.000 A 86% ACS40US24 36.0 V 1.110 A 1.330 A 87% ACS40US36 48.0 V 0.834 A 1.000 A 88% ACS40US48 3.3 V 8.000 A 8.500 A 74% ACS60US03 5.0 V 8.000 A 9.000 A 78% ACS60US05 9.0 V 6.670 A 8.000 A 82% ACS60US09 12.0 V 5.000 A 6.000 A 84% ACS60US12 60 W 15.0 V 4.000 A 4.800 A 85% ACS60US15 24.0 V 2.500 A 3.000 A 86% ACS60US24 36.0 V 1.670 A 2.000 A 87% ACS60US36 48.0 V 1.250 A 1.500 A 88% ACS60US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%. Mechanical Details 1.20 (30.48) 4.00 (101.6) 0.15 (3.8) 3.70 (94.0) 0.15 (3.8) N (+) Vout 2.00 L (50.8) (-) Vout 1.70 (43.2) 0.125 (3.17) (4 Places) Notes 1. All dimensions shown in inches (mm). 2. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. Output connector mates with Molex housing 90-50-3041 and Molex 2878 series crimp terminal. 3. Loom kits with 300 mm wire available. Order part number ACS40/60 LOOM KIT. 4. For mating connectors only, order part number ACS20-60 CONKIT. 5. Covers available. Order part number ACS40/60 COVER (114 x 64 x 38.5mm). To receive unit with cover fitted, add suffix -C to model number. 08-Aug-12