30-60 Watts xppower.com AFM Series Energy Efficiency Level V CEC2008 & EISA2007 Compliant IT & Medical Approvals China Compulsory Certification (CCC) Qualified Optional Class II Versions Optional White Case Versions 3 Year Warranty Specification Input General Input Voltage 80-264 VAC, derate output power Efficiency See table Energy Efficiency Level V 25% <90 VAC Isolation 4000 VAC Input to Output, 2 x MOPP Input Frequency 47-63 Hz 1500 VAC Input to Ground, 1 x MOPP* Input Current AFM30: 0.8 A rms at 115VAC, Output 0 V is electrically connected to AFM45: 1.2 A rms at 115VAC, Input Ground*. *Not C8 version. AFM60: 1.5 A rms at 115 VAC Switching Frequency 30/45 W: 58 kHz typ., 60 W: 52 kHz typ. Inrush Current AFM30: 50 A max at 240VAC, 3 3 Power Density AFM30: 2.8 W/In , AFM45: 4.2 W/In , AFM45: 120 A max at 240VAC, 3 AFM60: 3.76 W/In AFM60: 120 A max at 240VAC MTBF >250 kHrs to MIL-HDBK-217F at 25 C, Power Factor EN61000-3-2, class A GB, full load Earth Leakage Current 150 A max at 264 VAC/60 Hz No Load Input Power AFM30/45: <0.3 W, AFM60: <0.5 W Environmental Operating Temperature 0 C to +60 C, derate from 100% power at +40 C to 60% power at +60 C Output Operating Humidity 10-95% RH, non-condensing Output Voltage See table Storage Temperature -40 C to +80 C Output Voltage Trim Not user-adjustable Operating Altitude 2000 m Initial Set Accuracy 2% Shock 30 g, 10 ms on 3 axes Minimum Load No minimum load required 2 Vibration 5-100 Hz, 2.31 m/s , 20 mins, 3 axes Start Up Delay 3 s max at 115 VAC Hold Up Time 8 ms minimum at 115 VAC EMC & Safety Line Regulation 1.0% maximum Emissions EN55011/32/FCC Class B conducted, Load Regulation 2.5% maximum EN55011/32/FCC Class B radiated Transient Response 4% max. deviation, recovery to within Harmonic Currents EN61000-3-2, Class A 1% in 500 s for a 25% load change Voltage Flicker EN61000-3-3 (1) Ripple & Noise 1% max pk-pk ESD Immunity EN61000-4-2, 6 kV contact and Overvoltage Protection 110-170% Vnom, recycle input to reset 8 kV air discharge Overload Protection AFM45/60: 110-170%, Radiated Immunity EN61000-4-3, 3 V/m Perf Criteria A AFM30: 110-220%, auto recovery (9) EFT/Burst EN61000-4-4, level 3 Perf Criteria A Short Circuit Protection Trip and restart (hiccup mode) Surge EN61000-4-5, installation class 3 Temperature 0.04%/C Perf Criteria A Coefficient Conducted Immunity EN61000-4-6, 3 Vrms Perf Criteria A Magnetic Field EN61000-4-8, 3 A/m, Perf Criteria A Dips & Interruptions EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, (8) Perf A, A, A, B Safety Approvals IEC62368-1-1:2014 / IEC60950-1:2005 Ed 2. UL60950-1, EN62368-1:2014/A11:2017 EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.), IEC60601-1 (3rd Ed.) China Compulsory Certification (CCC) Qualified. AC-DCAC-DC 1.41 (36.0) AFM30-60 Models and Ratings (6) (7) (3,4,5) Output Power Output Voltage Output Current Efficiency Model Number 30 W 12 V 2.50 A 87.9% AFM30US12 30 W 15 V 2.00 A 88.4% AFM30US15 30 W 18 V 1.67 A 87.6% AFM30US18 30 W 24 V 1.25 A 88.0% AFM30US24 48 W 12 V 4.00 A 87.7% AFM45US12 48 W 15 V 3.20 A 88.0% AFM45US15 48 W 18 V 2.67 A 87.2% AFM45US18 48 W 24 V 2.00 A 87.7% AFM45US24 60 W 12 V 5.00 A 87.3% AFM60US12 60 W 15 V 4.00 A 88.2% AFM60US15 60 W 18 V 3.34 A 88.3% AFM60US18 60 W 24 V 2.50 A 87.8% AFM60US24 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 5. For white case version add suffix -W. MOQ applies, contact sales for details. 0.1 F ceramic cap connected at the measurement point. 6. Other output voltages are available, contact sales for details. 2. Total regulation includes initial set accuracy, line and load regulation. 7. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix C2 8. A minimum load of 1% is required to meet performance criteria A. to the model number, e.g. AFM60US24C2. 9. Performance criteria given for high line input. 4. For alternative IEC320-C6 inlet, add suffix C6 to the model number eg. AFM60US24C6. Mechanical Details 37.4 2 (950 50) 1.31 Output Plug: 5.5 x 2.5 x 11.0 mm (33.4) inner positive LED Indicator A Optional AC Cable Restraint (see note 8 below) 0.53 (13.7) 0.66 0.07 (16.8) (1.8) 80 C 0.68 (17.3) 0.17 (4.4) B AFM30 & 45 AFM60 A 4.76 (121.0) 4.92 (125.0) B 1.97 (50.0) 2.44 (62.0) Standard AC INLET Optional C6 AC INLET Optional C8P AC INLET C 1.21 (30.8) 1.33 (34.0) IEC-320-C14 IEC-320-C6 IEC-320-C8P Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except 7. For US mains lead order part US-MAINS-IEC for C14 versions, output cable length. US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions. 2. Weight: AFM30/45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx. 8. For optional AC Cable Restraint on the standard input version add suffix A to 3. Case material is PC Class 94 V-0. the model number e.g. AFM60US24A. AC Mains Lead must be Interpower 4. Output Lead: UL1185, 16 AWG Corporation, part number 70006020300. Option AC Cable Restraint is not 5. For European mains lead order part EU-MAINS-IEC for C14 versions, available on IEC320-C6 inlet or Class II versions. EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions. 9. The standard C7 cable fits the C8P connector. 6. For UK mains lead order part UK-MAINS-IEC for C14 versions, UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions. 17 Nov 2020