DC-HVDC Converter AG Series 1 & 1.5 Watt Output voltages from 100V to 6000V xxx Series Output Proportional to Input 0.7VDC Turn-on Voltage Extremely Low Profile <0.25 Surface Mount Input to Output Isolation Short Circuit Protection Control Pin No minimum load Dimensions: 3 Year Warranty All models: The AG Series is a broad line of ultra-miniature DC to HV DC converters that sets an industry standard Height x Width: 0.25 x 0.45 (6.35 x 11.43mm) in high voltage miniaturization. This unique package occupies less than one tenth of a cubic inch of 100V to 2000V outputs: 6000V outputs: volume and an extremely low profile of only 0.128 inches (3.25mm) when mounted in from the top, or Length: 1.33 (33.78mm) Length: 0.92 (23.37mm) 0.152 (3.86mm) when mounted in from the bottom of the PCB. They can also mount off the PCB 3000V to 5000V outputs: with .030 diameter pins. They are offered in 1 watt or 1.5 watt power ratings, with output voltages Length: 1.13 (28.69mm) ranging from 100 volts to 6000 volts. The output is directly proportional to the input voltage and is Dimensions do not include the surface mount tabs, see mechanical details. linear from <0.7V input to maximum input voltage. Output is load dependent. Isolation permits <500V bias on output return. No external components or minimum load are required. Key Applications: A separate high impedance control pin is standard and is designed for external error amplifier and/or Avalanche Photo Diodes DAC control in closed or open loop systems, or simply connect the control pin to the + input for Photo Multiplier Tubes proportional input to output operation. Use of a resonant, quasi-sinewave oscillator and fully shielded Electrophoresis transformer result in clean, reliable high voltage conversion with inherently low ripple, EMI/RFI and Capacitor Charging Sustaining Ion Pumps input ripple current, making this product ideal for integration into noise sensitive equipment. Piezo Devices Handheld Instruments Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 0.7 5,12,24 VDC See Models and Ratings Table. Input Current 550 mA See Models and Ratings Table. Control Voltage Input Analog Control Voltage adjusts output from 0 to 100%, not to exceed Input Voltage, see Application Notes. Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 6,000 VDC See Models and Ratings Table Output Current 15 mA See Models and Ratings Table Output Voltage Tolerance +10, -10 % At Max Vout, Full Load Minimum Load No minimum load required Regulation Unregulated, Output is proportional to Input. See Application Notes. Short Circuit Protection Protected against short circuit conditions for a minimum 1 minute. Ripple and Noise 0.3 5 % See Models and Ratings Table. Notes 1. Maximum output current is available at maximum rated output voltage, and 3. Specifications are after 30 minute warm-up, full-load at 25C, unless otherwise derates linearly as input voltage is decreased. noted. 2. Output Voltage is load dependent. Under light or no-load conditions, reduce 4. Proper thermal management techniques are required to maintain safe case the Input Voltage so maximum rated Output Voltage is not exceeded. temperature at maximum power output. www.xppower.com 1Preheat/Soak Temp T 120C smin Temp T 180C smax time t (t to t ) 77sec s smin smax Time Above Liquidus Temp T 217C L 44sec time t L Peak Temp T 237.5C P Peak time >230C t 16sec P Time 38.5C to Peak T 4min 18sec P Max Ramp Rates +/-2.6C/sec DC-HVDC Converter AG Series Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature (case) -25 +75 C Standard operating temp, all models Operating Temperature (case) -55 +85 C Extended operating temp, -T models Storage Temperature -55 +105 C Humidity 95 %RH Non-condensing Cooling Natural Convection Safety Approvals Safety Agency Safety Standard Notes & Conditions UL IEC/UL/CSA/EN 62368 CE CE Directive, RoHs and LVD Where applicable RoHS RoHS 2 and 3 Directive (2011/65/EU) Where applicable General Characteristic Minimum Typical Maximum Units Notes & Conditions Isolation: Input to Output 500 V < 500 VDC Bias on Output Return Leakage Current 100 nA Switching Frequency 50 350 kHz Construction Solid vacuum encapsulation, UL 94 V-0 rated. Mean Time Between Failure 1.862 MHrs Bellcore TR-332, GB, +25C Block Diagram Connections 1 (-) Input 2 (+) Input 3 HV Out 4 HV RTN 5 Control Recommended Solder Profile www.xppower.com 2