AC-DC Power Supplies AHE220 Series 220 Watts Energy Efficiency Level VI <0.21 W Standby Power 0 C to 60 C Operation High Power Density Low Earth Leakage Current ITE Safety Approvals 3 Year Warranty Dimensions: AHE220: 7.76 x 3.46 x 1.73 (197.0 x 88.0 x 44 mm) Models & Ratings (1) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number (2) 180 W 12.0 V 15.0 A 90% AHE220PS12 19.0 V 11.57 A 5% 92% AHE220PS19 220 W 24.0 V 9.16 A 94% AHE220PS24 Notes 1. Typical efficiency measured at 100% load and 230 VAC input. 2. For IEC320-C6, add suffix C6 to the end of the part number e.g. AHE220PS12C6. Mechanical Details 6 3 5 2 AHE220PS19/24 4 1 1 3 Mains Leads Order Part: AHE220PS12 UK - C14 inlet: UK-MAINS-IEC, C6 inlet: UK-MAINS-5 2 4 1.73 European - C14 inlet: EU-MAINS-IEC, C6 inlet: EU-MAINS-5 (44.0) US - C14 inlet: US-MAINS-IEC, C6 inlet: US-MAINS-5 Rubber foot Pin Connector (4 places.) AHE220PS12 Pin Function 1 Output + 2 Output + 3 Return/Input Earth 4 Return/Input Earth Shell Return/Input Earth AHE220PS19/24 Pin Function 3.46 (88.0) 1 Return/Input Earth 2 Return/Input Earth Cable Length 3 Return/Input Earth 4 Output + PS12 - 37.4 1.97 (950 50mm) 5 Output + Optional AC Input PS19/24 - 59.1 1.97 (1500 50mm) IEC 320/C6 Inlet IEC 320/C14 Inlet 6 Output + (12 V model only) Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, 4. Output connector for AHE220PS12 is non locking 4 pin DC power plug and mates except output cable length. with Kycon KPJX-4S or equivalent. 2. Weight: 2.31 lb (1050 g). Output connector for AHE220PS19/24 is molex Mini-Fit part number 39-01-2060 3. Optional output connectors available. Consult sales. with 5556 terminals and mates with molex plug 39-01-2066 and 5558 terminals or equivalent. 5. Mains lead length is 76 (1930 mm) approx www.xppower.com 1 0.02 (0.5) 7.76 (197)AC-DC Power Supplies AHE220 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 2.34/0.98 A Measured at 100/240 VAC Inrush Current 80/160 A 115/230 VAC, cold start at 25 C Power Factor 0.9 At 230 VAC and full load, EN61000-3-2 Class A Earth Leakage Current 220 250 A 264 VAC, 60 Hz No Load Input Power 0.21 W Input Protection T3.15A/250 VAC internal fuse in line Output Characteristic Min. Typ. Max. Units Notes & Conditions Output Voltage 12 24 VDC See Models and Ratings table Initial Set Accuracy 2 % At 50% load Minimum Load No minimum load required Start Up Delay 3 s Start Up Rise Time 40 ms Hold Up Time 10 ms Full load and 115 VAC Line Regulation 0.5 % Total Regulation 5 % Maximum deviation, recovering to less than 1% within Transient Response 4 % 500 s for 25% step load Measured with 20 MHz Bandwidth and 10 F electrolytic in Ripple and Noise 7 %/pk-pk parallel with 0.1 F ceramic capacitor. Overshoot 5 % At turn on / turn off Overload Protection 115 175 % Overvoltage Protection 112 160 % Recycle mains to reset Short Circuit Protection Trip and restart (hiccup), auto resetting Thermal Protection Measured internally, recycle AC to reset Temperature Coefficient 0.04 %/C Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 50% load at 60 C Cooling Natural convection Operating Humidity 5 90 %RH Non-condensing Storage Temperature -10 +80 C Operating Altitude 5000 m Shock IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Derating Curve 100% 80% 60% 40% 20% 0 20 40 60 Ambient Temperature (C) www.xppower.com 2 Output Power (%)