AKM45 Series AC-DC POWER SUPPLIES CONVECTION 45W COOLED The AKM45 series of desktop adaptors comply with medical, home-healthcare and ITapprovals along with the latest energy efficiency level VI standards with high active mode efficiency and extremely low no load power consumption. Available with a standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Features Applications IP22 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical (2 x MOPP) and ITE approvals Healthcare Industrial Medical Technology Electronics Diagnostic 4th edition medical EMC Class I & class II versions Dimensions Input voltage range 80 to 264VAC 4.82 x 2.02 x 1.24 (122.4 x 51.4 x 31.5 mm) Output voltages from 9 to 48VDC 0C to +60C operating temperature 3 years warranty Models & Ratings (3)(4) (1) (2) Model Number Output Power Output Voltage Output Current Total Regulation Efficiency AKM45US09 40.5W 9.0 V 4.50 A 89.8% AKM45US12 12.0 V 4.00 A 90.5% AKM45US15 15.0 V 3.20 A 90.5% 5% AKM45US18 48W 18.0 V 2.66 A 90.6% AKM45US24 24.0 V 2.00 A 90.2% AKM45US48 48.0 V 1.00 A 91.2% Notes: 1. Total regulation includes initial set accuracy, line and load regulation. 2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC. 3. For white case version add suffix -W e.g. AKM45US12-W. MOQ applies, contact sales for details. 4. Model number shown in the table is for Class I version. For Class IIversion add suffix C2, e.g. AKM45US24C2.AC-DC POWER SUPPLIES AKM45 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 80 264 VAC Input Frequency 47 63 Hz Input Current 1.3 A 90VAC Inrush Current 100 A 230VAC, cold start at 25C No Load Input Power 75 mW Input Protection Internal fuse in both line and neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 9 48 V See Models and Ratings table Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 30 55 ms Hold Up Time 10 ms Full load and 100VAC Total Regulation 5 % See Models and Ratings table Recovery within <1% within 500s for a 60% step load Transient Response 4 % deviation change at 0.15A/s Measured with 20MHz bandwidth and 10F electrolytic in Ripple and Noise 200 mV pk-pk parallel with 0.1F ceramic capacitor Overload Protection 130 160 % Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovery Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Typical average of efficiencies measured at 25%, 50%, Efficiency 89 % 75% and 100% load and 115VAC input Energy Efficiency Level VI 4000 Input to output, 2 x MOPP Isolation: Input to Output Input to Ground 1500 VAC Class I version only Output to Ground 1500 Class I version only Leakage Current 100 A 264VAC, 60Hz Switching Frequency 24 70 kHz Variable Mean Time Between Failure 250 khrs MIL-HDBK-217F at 25C GB Weight 0.75 (340) lb (g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Derate from 100% load at 40 C to 50% load at 60 C. Operating Temperature 0 +60 C Agency approval to 40 C max. Storage Temperature -25 +70 C Ingress Protection IP22 Cooling Natural convection Operating Humidity 5 90 % RH, non-condensing Operating Altitude 5000 m Shock 1m drop onto concrete on each of 6 axes, non operating Vibration 2g, 0.3 decades/min, 15 mins for each of 3 axes 2