AMF24 Series AC-DC POWER SUPPLIES EXTERNAL 24W WALL PLUG The AMF24 series of wall plug adaptors comply with medical and home-healthcare approvals along with the latest energy efficiency level VI standards with high active mode efficiency and extremely low no load power consumption. Available with a range of interchangeable AC connectors these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Features Applications IP22 ingress protection IEC/EN60601-1-11 for home healthcare applications Energy efficiency level VI & EU2019/1782 Medical and home healthcare approvals Healthcare Home Medical Healthcare Diagnostic Interchangeable mains connectors Input voltage range 80 to 264VAC Dimensions Output voltages from 9V to 48VDC 3.56 x 1.32 x 2.3 (90.5 x 33.5 x 58.5mm) Optional white versions Class II construction 3 Years warranty Models & Ratings (1,2,5) (3) (4) Model Number Output Power Output Voltage Output Current Total Regulation Efficiency AMF24US09 9.0V 2330mA 86.4% AMF24US12 12.0V 2000mA 87.9% AMF24US15 15.0V 1600mA 87.3% 24W 5% AMF24US18 18.0V 1330mA 88.6% AMF24US24 24.0V 1000mA 88.8% AMF24US48 48.0V 500mA 88.3% Notes: 1. Model number is for body only. ACinput plugs must be ordered separately, see AC input plug section. 2. Other output voltages available, contact sales for details. 3. Total regulation includes initial set accuracy, line and load regulation. 4. Typical average value measured at 25%, 50%, 75% and 100% at 230VAC. 5. For white case version add suffix -W e.g. AMF24US12-W. MOQ applies, contact sales for details.AC-DC POWER SUPPLIES AMF24 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 80 264 VAC Input Frequency 47 63 Hz Input Current 0.6 A Measured at 80VAC Inrush Current 70 A 240VAC, cold start at 25C Power Factor EN61000-3-2, class A No Load Input Power 75 mW Input Protection Internal fuse in line Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 9 48 V See Models and Ratings table Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 10 40 ms Hold Up Time 10 ms Full load and 100VAC Total Regulation 5 % See Models and Ratings table Recovery within <1% within 500s for a 60% step load change at Transient Response 4 % deviation 0.15A/s Measured with 20MHz bandwidth and 10F electrolytic in parallel Ripple & Noise 200 mV pk-pk with 0.1F ceramic capacitor Over Voltage Protection 110 200 % Auto recovery Over Load Protection 115 180 % Leakage Current 50 A At 264VAC, 60Hz, from output to ground Temperature Coefficient 0.05 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Typical average of efficiencies measured at 25%, 50%, 75% and Efficiency 88 % 100% load and 230VAC input Energy Efficiency Level VI Input to Output, 2 x MOPP Isolation 4000 VAC Suitable for BF applications Switching Frequency 24 80 kHz Variable Mean Time Between Failure 200 khrs MIL-HDBK-217F at 25C GB Weight 0.37 (170) lb (g) Body only 2