CCB200 Series 200 W Convection Cooled at +70 C Industry Standard 3 x 5 Package Very Low Heat Loss GREEN POWER Very High Efficiency up to 95% Very Long Capacitor Lifetime 1U Form Factor <0.5 W Standby Power 80 V - 300 VAC Input Operation IT & Medical (BF) Safety Approvals Remote On/Off & Power Fail Signal as Standard 5 V Standby (Optional) Covers Available The CCB200 range of single output AC-DC 200 W power supplies feature industry leading efficiency of up to 95% and absolute minimum efficiency of 93% with 90 VAC input and full load. This leap in efficiency particularly at low input voltages has been achieved by harmonising digital circuitry with resonant zero current switching techniques. These techniques coupled with close attention to even the smallest levels of power loss within the unit, have resulted in a convection cooled power supply packaged in a 3 (76.2mm) x 5 (127mm) x 1.43 (36mm) open frame design unequalled in the market today. System designers can easily integrate the CCB200 into a wide variety of end use applications due to the very low levels of heat dissipated from the supply. This low dissipation results in lower component temperatures and extended lifetime by as much as four times when compared to other convection cooled products with similar power density. The 200W of power is available without derating over the full input (90V 264V AC) and temperature range (-20C to +70C). The five standard models cover the voltage range from 12V - 56V, have dual input fusing and are compliant with IEC60601-1 Medical (BF) and IEC62368-1 IT safety approvals.xppower.com Models and Ratings - Convection-cooled Output Power Output Voltage V1 Output Current V1 5 V Standby (Optional) Model Number 200 W 12.0 V 16.7 A 5 V/0.5 A CCB200PS12 200 W 15.0 V 13.3 A 5 V/0.5 A CCB200PS15 200 W 24.0 V 8.3 A 5 V/0.5 A CCB200PS24 200 W 28.0 V 7.1 A 5 V/0.5 A CCB200PS28 200 W 48.0 V 4.2 A 5 V/0.5 A CCB200PS48 200 W 56.0 V 3.6 A 5 V/0.5 A CCB200PS56 1. Add suffix -C for covered version, e.g. CCB200PS12-C. 2. Add suffix -A for 5 V standby option, or -AC for standby and cover options combined. Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output power <90 VAC. See fig 1. Input Voltage - Operating 80 115/230 300 VAC Power fail signal cannot be used <90 VAC. Input Frequency 47 50/60 63 Hz Power Factor >0.9 EN61000-3-2 class A compliant Input Current - Full Load 1.8/0.9 A 115/230 VAC Inrush Current 40 A 230 VAC, 25 C No Load Input Power 0.5 W Under inhibit condition Earth Leakage Current 75/145 250 A 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.) Input Protection T5.0A/250 V internal fuse in both line and neutral Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 56 VDC See Models and Ratings table Initial Set Accuracy 0.5 % 50% load, 115/230 VAC Output Voltage Adjustment -4 +5 % V1 only via potentiometer. See mech. details (page 8). Minimum Load0A Start Up Delay 0.5 s 230 VAC full load Hold Up Time 20 ms 90 VAC full load Drift 0.2 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC Load Regulation 1 % 0-100% load. Recovery within 1% in less than 500 s Transient Response - V1 4% for a 50-75% and 75-50% load step Ripple & Noise 1 % pk-pk 20 MHz bandwidth Overvoltage Protection 115 140 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 110 150 % I nom Output 1 only, auto reset (see fig.2) Short Circuit Protection Continuous, trip & restart (hiccup mode) all outputs Temperature Coefficient 0.05 %/C Overtemperature Protection C Not Fitted Patient Leakage Current 75 100 A 264 VAC/60 Hz 2