AC-DC Power Supplies CCL400 Series 400 Watts 400 W Convection-cooled Conduction Cooling For Higher Ambient Operation 94% Efficiency 85 VAC to 264 VAC Input 5V Standby <1W Standby Power IT & Medical Safety Approvals Power Fail & Inhibit Signals 3 Year Warranty Dimensions: The universal AC input CCL400 provides 400W of convection cooled output power over the CCL400: temperature range -40C to +50C with derating to +70C. The temperature range can be 7.00 x 3.95 x 1.57 (178 x 100 x 40 mm) CCL400-C: extended by the use of conduction cooling to the full 400W at +70C. Approved for IT and Medical 7.39 x 4.04 x 1.92 (189.9 x 107.3 x 48.9 mm) and with a feature set including a 5V standby output, <0.5W standby power, power fail and inhibit signals the CCL400 is ideal for a wide range of applications where fan cooling is not desirable. Models & Ratings (1,2) Output Voltage 1 Output Current V1 Standby Supply V2 Output Power Model Number 12 V 33.3 A 5.0 V / 0.5 A 400 W CCL400PS12 24 V 16.6 A 5.0 V / 0.5 A 400 W CCL400PS24 30 V 13.3 A 5.0 V / 0.5 A 400 W CCL400PS30 48 V 8.3 A 5.0 V / 0.5 A 400 W CCL400PS48 Notes 1. Add suffix -C for cover version e.g. CCL400PS24-C 2. Add suffix -SC for a right angled input screw terminal connector on a covered version e.g. CCL400PS24-SC. Mechanical Details 7.12 (180.86) 2 x M3 max depth 1.0 Detail A, Scale 1:1 6.6 (167.64) 0.16 (4.0) (25.4) Signals Connector CON4 10 way JST B10B-PHDSS Pin 2 Pin 1 1.57 (39.88) 0.4 (10.16) Pin 10 Pin 9 0.9 (22.86) 5.2 (132.08) 7.0 (177.8) Output Voltage A Control 3.95 (100.33) 2.45 (62.23) +VE 1 -VE 2 3 Input Connector CON1 Output Terminal 2 x M3 max depth 0.75 (19.05) 6.6 (167.64) 4 x M3 max depth 0.12 (3.0) M4 Screw in 0.16 (4.0) 0.4 (10.16) 2 positions Torque to 8lbs-in (90 cNm) max. 1.0 (25.4) www.xppower.com 1AC-DC Power Supplies CCL400 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output power < 100 VAC for convection cooling or Input Voltage - Operating 85 115/230 264 VAC <90 VAC for conduction cooling. See fig. 1 Input Voltage - Fault Condition 300 VAC 5 seconds max Input Frequency 47 50/60 63 Hz Agency approval, 47-63 Hz EN61000-3-2 class A compliant Power Factor >0.95 EN61000-3-2 class C for loads 10% Input Current - Full Load 3.8/1.9 A 115/230 VAC No Load Input Power 1 W All models, when inhibit activated Inrush Current 35 60 A 230 VAC Earth Leakage Current 90/180 250 A Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz Input Protection F10.0 A 250 V internal fuse in both AC lines Input Voltage Derating Figure 1 Conduction Cooled with and without cover 400 Convection Cooled without cover 350 300 Convection Cooled with cover 200 100 0 85 90 100 264 Input Voltage (V) Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 0.5 % 50% load, 115/230 VAC Output Voltage Adjustment 3 % Minimum Load 0 A Start Up Delay 1.5 2.0 s 115/230 VAC full load from input AC turn on Hold Up Time 30 ms Drift 0.2 % After 20 min warm up Line Regulation 0.5 % Load Regulation 0.5 % Recovery within 1% in less than 500 s Transient Response <4 % for a 50-75%-50% load change Ripple & Noise 1 % pk-pk 20 MHz bandwidth Overvoltage Protection 115 140 % Vnom DC. Output 1, recycle input to reset Overload Protection 110 150 % Trip & Restart characteristic V1 Short Circuit Protection Shutdown and auto recovery Temperature Coefficient 0.05 %/C Overtemperature Protection Shutdown and auto recovery www.xppower.com 2 Output Power (W)