5-60 Watts xppower.com DNR Series Rugged Design for Industrial Applications Up to 89% Efficiency Full Power to +60 C Wide Adjustment Range DC OK 24 V Models DC Standby Versions 3 Year Warranty Specification Input General Input Voltage 90-264 VAC, 120-375 VDC (DNR05/10/18) Efficiency See tables 85-264 VAC, 90-375 VDC (DNR30/60) Isolation 3000 VAC Input to Output, 1500 VAC Input Input Frequency 47-63 Hz to Ground, 500 VAC Output to Ground Input Current See tables Switching Frequency 132 KHz typical, 55-90 kHz (DNR60) Inrush Current 5-18 W: 15/30 A at 115/230 VAC Signals DC ON indicator LED Green: All models 30 W: 20/40 A at 115/230 VAC DC LOW indicator LED Red: 5-18 W models 60 W: 30/60 A at 115/230 VAC DC OK: 24 V 30-60 W models DC OK: All standby models Power Factor EN61000-3-2, class A MTBF 800 kHrs typical Bellcore, Issue 6 at +40 C, Earth Leakage Current 0.8 mA max GB (DNR05/10/18), 530 kHrs typical Input Protection Internal fuse T2A, 250 VAC fitted in line Bellcore, Issue 6 at +40 C, GB (DNR30/60) DIN Rail Compatible with TS35/7.5 or TS35/15 Output Output Voltage See tables Environmental Output Voltage Trim See tables Operating Temperature -20 C to +70 C (DNR05/10/18) Initial Set Accuracy 1% -40 C to +70 C, start up at -35 C Minimum Load No minimum load required (DNR30/60), all units derate linearly from Start Up Delay <1 s (may increase at low 60 C (see derating curves) temperature extremes) Cooling Convection-cooled with 25mm free space Start Up Rise Time <150 ms all sides Hold Up Time 30/130 ms at 115/230 VAC (DNR05) Operating Humidity 20-95% RH, non-condensing 25/100 ms at 115/230 VAC (DNR10) Storage Temperature -25 C to +85 C (DNR05/10/18) 20/75 ms at 115/230 VAC (DNR18) -40 C to +85 C (DNR30/60) 20/30 ms at 115/230 VAC (DNR30) Shock 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis in 2 0/30 ms at 115/230 VAC DNR60) both directions Line Regulation 5-18 W: 1.0% max Vibration 2 g, 10 Hz to 500 Hz, along X, Y & Z axis, 30-60 W: 0.5% max 60 mins/axis, mounted on rail Load Regulation 5-18 W: 2.0% max 30-60 W: 0.5% max EMC & Safety Parallel Operation Redundancy module DPM10 available for load currents up to 10 A (not with Emissions EN55022, level B conducted & radiated standby system), contact sales Harmonic Currents EN61000-3-2, class A Transient Response 4% max deviation recovery to within Voltage Flicker EN61000-3-3 1% in 2 ms for a 50% load change ESD Immunity EN61000-4-2, level 4, Perf Criteria A Ripple & Noise 50 mV pk-pk, 20 MHz bandwidth (may Radiated Immunity EN61000-4-3, level 3, Perf Criteria A increase at low temperature extremes) EFT/Burst EN61000-4-4, level 4, Perf Criteria A Overvoltage Protection Output clamps at 120-145% Vnom, Surge EN61000-4-5, installation class 3, auto recovery Perf Criteria A Overload Protection 110-165% constant current (DNR05-18) 105-150% power limited (DNR30/60) Conducted Immunity EN61000-4-6, level 3, Perf Criteria A Short Circuit Protection Power limited, auto recovery Magnetic Field EN61000-4-8, level 4 Perf Criteria A Temperature 0.03%/C Dips & Interruptions EN61000-4-11, 30% 10 ms, Coefficient 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals EN60950-1, UL508 Pollution Degree 2, UL1310 class 2 power recognised, See note 3 & ratings table, UL60950-1 Overvoltage Category II, UL508 Overvoltage Category III, DNR30 & DNR60: SEMI F47 ANSI/ISA 12.12.01. Class 1, Division 2 Groups A,B,C and D AC-DCAC-DC DNR05-60 Models and Ratings Input Current (typ.) Output Output Output Current Efficiency (typ.) Model Number 115 VAC 230 VAC Voltage Voltage Trim (1) 5 V 0.12 A 0.08 A 4.50-5.75 V 1.000 A 69% DNR05US05 (1) 12 V 0.12 A 0.08 A 10.80-13.80 V 0.420 A 72% DNR05US12 (1) 15 V 0.12 A 0.08 A 13.50-17.25 V 0.340 A 72% DNR05US15 (1) 24 V 0.12 A 0.08 A 21.60-28.80 V 0.210 A 72% DNR05US24 (1) 5 V 0.20 A 0.13 A 4.50-5.75 V 2.000 A 73% DNR10US05 (1) 12 V 0.20 A 0.13 A 10.80-13.80 V 0.840 A 75% DNR10US12 (1) 15 V 0.20 A 0.13 A 13.50-17.25 V 0.670 A 76% DNR10US15 (1) 24 V 0.20 A 0.13 A 21.60-28.80 V 0.420 A 76% DNR10US24 (1) 5 V 0.36 A 0.21 A 4.50-5.75 V 3.000 A 75% DNR18US05 (1) 12 V 0.36 A 0.21 A 10.80-13.80 V 1.500 A 77% DNR18US12 (1) 15 V 0.36 A 0.21 A 13.50-17.25 V 1.200 A 77% DNR18US15 (1) 24 V 0.36 A 0.21 A 21.60-28.80 V 0.750 A 77% DNR18US24 (1,3,4) 5 V 0.56 A 0.33 A 5.00-5.50 V 6.000 A 79% DNR30US05 (1,3,4) 12 V 0.56 A 0.33 A 12.00-14.00 V 2.500 A 84% DNR30US12 (1,3,4) 24 V 0.56 A 0.33 A 24.00-28.00 V 1.250 A 86% DNR30US24 (1,3,4) 48 V 0.56 A 0.33 A 48.00-55.00 V 0.625 A 86% DNR30US48 (1,3,4) 5 V 1.10 A 0.59 A 5.00-5.50 V 10.000 A 79% DNR60US05 (1,3,4) 12 V 1.10 A 0.59 A 12.00-14.00 V 5.000 A 86% DNR60US12 (1,3,4) 24 V 1.10 A 0.59 A 24.00-28.00 V 2.500 A 89% DNR60US24 (1,3,4) 48 V 1.10 A 0.59 A 48.00-55.00 V 1.250 A 89 % DNR60US48 Notes 1. Add suffix -S for spring clamp connection option. 3. Approved to UL1310, but 5 & 12 V not Class 2 Power recognised. 2. 30-60 W models are suitable for battery-charging applications. 4. SEMI F47 compliant. Derating Curves , DNR05-18 W Models 100 80 60 40 20 0 -20 0 10 20 30 40 50 60 70 DNR30-60 W Models 100 80 60 40 20 0 -40 0 10 20 30 40 50 60 70 Ambient Temp (C) Load (%) Load (%)