xppower.com 120 960 Watts DNR120 960TS Series Three Phase AC Input Up to 93% Efficiency Wide Adjustment Range Full Power 40 C to +60 C Rugged Design for Industrial Applications Single Phase Input Operation (340 575 VAC) 3 Year Warranty Specification Input General Input Voltage 340-575 VAC 3 phase (single phase Efficiency See table operation with 75% of rated output), Isolation 3000 VAC Input to Output, 1500 VAC 480-820 VDC Input to Ground, 500 VAC Output to Input Frequency 47-63 Hz Ground Input Current See tables Switching Frequency DNR120TS: 70 kHz typical, DNR240TS: 25 kHz typical, Inrush Current DNR120: 10.0 A, DNR240: 20.0 A, DNR480TS: 80 kHz typical, DNR480: 20.0 A, DNR960: 30.0 A, DNR960TS: 52 kHz typical typical at 480 VAC, cold start Signals DC ON indicator LED Green, Power Factor 0.6 typical at 480 VAC input and nominal DC LOW indicator LED Red load, DNR960TS: 0.8 typical at 480 VAC DC OK: normally open relay on 24 V models input and nominal load MTBF DNR120TS: 550 kHrs, 240TS: 500 kHrs Earth Leakage Current 0.32 mA 480TS: 420 kHrs, 960TS: 380 kHrs to Input Protection 3 internal fuses, Bellcore Issue 6, at +40 C, GB DNR120TS, DNR240TS: T2.0 A, 600 VAC, DIN Rail Compatible with TS35/7.5 or TS35/15 DNR480TS: T3.15 A, 500 VAC, DNR960TS: T5.0 A, 500 VAC Environmental Output Operating Temperature -40 C to 70 C (DNR480TS -30 C), derate linearly from 60 C at 2.5%/C Output Voltage See table (3.5%/C for DNR960TS), start up at Output Voltage Trim See table -35 C (DNR480TS -20 C) Initial Set Accuracy 1% see derating curves Minimum Load No minimum load required Cooling Convection-cooled with 25 mm free space Start Up Delay <1 s (may increase at low all sides temperature extremes) Operating Humidity 20-95% RH, non-condensing Start Up Rise Time <150 ms Storage Temperature -40 C to +85 C Hold Up Time 20 ms min at 480 VAC, Shock 15 g, 11 ms, 3 axis, 6 faces, 3 shocks/face DNR960TS: 15 ms min at 480 VAC Vibration 2 g, 10 Hz to 500 Hz, along X, Y & Z axis, Line Regulation 1% 60 min/axis, mounted on rail Load Regulation 1% max (5% for units in parallel (not DNR120TS)) EMC & Safety Parallel Operation 2 units can be connected in parallel Emissions EN55022, Class B conducted & radiated (not DNR120TS), total power available is Harmonic Currents EN61000-3-2, Class A 90% of the rated current of each unit, minimum load per unit 10%, use Ishare Voltage Flicker EN61000-3-3 connection for DNR960TS. Redundancy ESD Immunity EN61000-4-2, level 4 Perf Criteria A module DPM10 available for load currents Radiated Immunity EN61000-4-3, level 3 Perf Criteria A up to 10 A, contact sales EFT/Burst EN61000-4-4, level 4 Perf Criteria A Transient Response 4% max deviation recovering to within Surge EN61000-4-5, installation class 4, 1% in 2 ms for 50% load change Perf Criteria A Ripple & Noise 100 mV pk-pk 20 MHz bandwidth, Conducted Immunity EN61000-4-6, level 3 perf criteria A DNR960TS: 80 mV pk-pk 20 MHz bandwidth, (may increase at low Magnetic Field EN61000-4-8, level 4 perf criteria A temperature extremes) Dips & Interruptions EN61000-4-11, 30% 500 ms, Overvoltage Protection 120-145%, auto recovery 60% 200 ms, >95% 5000 ms Perf Criteria A, A, A Overload Protection 110%-140%, constant current, Safety Approvals EN60950-1 UL508 UL60950-1 auto recovery Pollution Degree 2, Temperature Coefficient 0.03%/C UL60950-1 Overvoltage Category II Short Circuit Protection Continuous trip and restart (hiccup mode) UL508 Overvoltage Category III, (DNR480TS switchable hiccup mode or ANSI/ISA 12.12.01 Class 1, Division 2, power limited ) Groups A,B,C and D AC DCAC DC DNR120 960TS Models and Ratings Input Current (typ.) Output Voltage (1) Output Voltage Output Current Efficiency (typ.) Model Number Trim 400 VAC 500 VAC 12 V 0.36 A 0.30 A 11.4-14.5 V 10.0 A 87% DNR120TS12 24 V 0.36 A 0.30 A 22.5-28.5 V 5.0 A 89% DNR120TS24 24 V 0.65 A 0.55 A 22.5-28.5 V 10.0 A 90% DNR240TS24-I 48 V 0.65 A 0.55 A 47.0-56.0 V 5.0 A 91% DNR240TS48-I 24 V 1.10 A 0.93 A 22.5-28.5 V 20.0 A 90% DNR480TS24-I 48 V 1.10 A 0.93 A 47.0-56.0 V 10.0 A 91% DNR480TS48-I 24 V 1.72 A 1.50 A 22.5-28.5 V 40.0 A 92% DNR960TS24-I 48 V 1.72 A 1.50 A 47.0-56.0 V 20.0 A 93% DNR960TS48-I Notes 1. Reduce by 25% for single phase input operation, (340-575 VAC). V Mechanical Details 0.3 5.91 (150.0) 4.39 (111.3) (7.0) DC Output Voltage Trim 6 1 + + -- DC DC OK OK DC LO ON 4.87 (123.6) DNR120TS DNR240TS DNR480TS 4.87 4.87 Voltage All Units (123.6) (123.6) DC LO Trim ON Voltage Trim AC Input DC Output Parallel Single DC DC L1 L2 L3 L1 L2 L3 L1 L2 L3 +V +V-V -V + + -- LO ON DC OK 5 4 1 1 4 1 4 56 1 44 1 Voltage Adj. 6 AC Input DC Output AC Input Single/parallel & current limit selector switches on underside 2.93 (74.3) 3.50 (89.0) DC OK signal connector on underside, Spring type, 2 AWG26-20/0.2-0.5 mm 10.86 (275.7) Pin Connections - DC Output DNR120 DNR240-480 DNR960TS Pin Designation Designation Designation 1 -V -V DC OK* 2 -V -V DC OK* 4.96 (8) DNR960TS (125.9) 3 +V +V +Ishare Pin Connections - AC Input (8) 4 +V +V -Ishare Pin Designation 5 DC OK* DC OK* +V 1 Ground DC Output 6 DC OK* DC OK* +V +V +V -V -V 2 L1 AC Input DC DC L1 L2 L3 DC DC 7 -V OK OK +Is-Is 3 L2 LO ON L 18 1 4 4 L3 8 -V Voltage trim on underside * Available on 24 V versions only Notes 1. All dimensions in inches (mm). 5. DC OK Relay rated at 60 VDC at 300 mA. 2. Tolerance: 0.02 (0.5) maximum. 6. Allow 0.98 (25 mm) clearance all round to ensure adequate ventilation. 3. Weight - DNR120TS: 1.76 lb (800 g) approx. 7. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm), DNR240TS: 2.43 lb (1100 g) approx. Output: 5.5 lbs-in (0.6 Nm). DNR480TS: 4.23 lb (1720 g) approx. 8. Connecting +Ishare and -Ishare between two power supplies will force the units DNR960TS: 7.05 lb (3200 g) approx. to current share. 4. Screw terminal: 10-24 AWG cable size. Derating Curves 100 A C B 75 A DNR120-240TS 65 B DNR960TS C DNR480TS 0 -40 -30 60 70 Ambient Temp (C) 11-May-11 Load (%)