40 Watts xppower.com ECP Series Low Profile Design Ultra Compact Size from 3x 2x 0.9 IT & Medical Approvals Single, Dual and Triple Output <0.3 W No Load Input Power Peak Load Capability 3 Year Warranty Specification Input General Input Voltage 85-264 VAC Efficiency See tables Input Frequency 47-63 Hz Isolation 4000 VAC Input to Output 1500 VAC Input to Ground Input Current 0.85 A max at 115 VAC 500 VAC Output to Ground Inrush Current 65 A max at 230 VAC Switching Frequency 40-130 kHz variable Power Factor EN61000-3-2, Class A MTBF >400 kHrs to MIL-HDBK-217F No Load Input Power <0.3 W at 25 C, GB Earth Leakage Current <250 A at 264 VAC, 60 Hz Input Protection Internal T2 A/250 V fuse in line and neutral Environmental Operating Temperature -10 C to +70 C, derate from 100% load Output at 50 C to 50% load at 70 C Output Voltage See table Cooling Natural convection Initial Set Accuracy Single output: 1% at 60% load, Operating Humidity 5% to 95% RH, non condensing Multiple output: 1% on V1, 5% on V2 Storage Temperature -40 C to +85 C & V3 at 60% load Shock 30 g pk, half sine, 6 axes Minimum Load 10% minimum load required on V1 & V2 Vibration 2 g rms, 5 Hz to 500 Hz, 3 axes of multi output versions Start Up Delay 1.3 s max EMC & Safety Start Up Rise Time 15 ms typical Hold Up Time 10 ms min at full load at 115 VAC Emissions EN55022, level B conducted & radiated Line Regulation 0.5% max Harmonic Currents EN61000-3-2, class A Load Regulation V1 & V3: 2%, V2: 4% (see note 3) Voltage Flicker EN61000-3-3 Cross Regulation V2: 5%, 10-100% load change on V1 ESD Immunity EN61000-4-2, 4 kV indirect contact, (see note 4) Perf Criteria A Transient Response 4% max deviation, recovering to less than Radiated Immunity EN61000-4-3, level 2, Perf Criteria A 1% within 500 s for 50% step load EFT / Burst EN61000-4-4, level 3 Perf Criteria A change at 1 A/s Surge EN61000-4-5, installation class 3, Ripple & Noise 1% pk-pk, measured with 20 MHz Perf Criteria A bandwidth Conducted Immunity EN61000-4-6, level 3, Perf Criteria A Overvoltage Protection 110-140% of nominal output voltage Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, on V1 only, recycle input to reset 100% 5000 ms, Perf Criteria A, B, B Overload Protection Single output: 140-160% of nominal power Safety Approvals UL62368-1, IEC62368-1, EN62368-1, Multiple output: 120-150% of nominal power ANSI/AAMI ES 60601-1, IEC60601-1, on V1 and V2 only EN60601-1, CE & UKCA meets all applicable directives & legislation. Short Circuit Protection Trip and restart (hiccup mode) Temperature 0.02%/C max Coefficient AC-DCAC-DC ECP40 Models and Ratings Output Output 1 Output 2 Output 3 Model (2) Efficiency (1) (1) Power Number Voltage Current Peak Voltage Current Peak Voltage Current 30 W 5.0 VDC 6.00 A 7.80 A 82% ECP40US05 40 W 12.0 VDC 3.34 A 4.34 A 89% ECP40US12 40 W 15.0 VDC 2.67 A 3.47 A 89% ECP40US15 40 W 18.0 VDC 2.22 A 2.89 A 90% ECP40US18 40 W 24.0 VDC 1.67 A 2.17 A 90% ECP40US24 40 W 30.0 VDC 1.34 A 1.74 A 91% ECP40US30 40 W 48.0 VDC 0.84 A 1.09 A 92% ECP40US48 40 W +5.0 VDC 5.00 A 7.80 A +12.0 VDC 2.0 A 2.60 A 89% ECP40UD01 40 W +5.0 VDC 5.00 A 7.80 A +15.0 VDC 1.5 A 1.95 A 90% ECP40UD02 40 W +5.0 VDC 5.00 A 7.80 A +24.0 VDC 1.0 A 1.30 A 90% ECP40UD03 40 W +5.0 VDC 5.00 A 7.80 A +12.0 VDC 2.0 A 2.60 A -12.0 VDC 0.5 A 89% ECP40UT01 40 W +5.0 VDC 5.00 A 7.80 A +15.0 VDC 1.5 A 1.95 A -15.0 VDC 0.5 A 90% ECP40UT02 40 W +5.0 VDC 5.00 A 7.80 A +24.0 VDC 1.0 A 1.30 A +12.0 VDC 0.5 A 90% ECP40UT03 40 W +5.0 VDC 5.00 A 7.80 A +24.0 VDC 1.0 A 1.30 A -12.0 VDC 0.5 A 90% ECP40UT04 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. Typical efficiency at 230 VAC and full load at 25 C. 3. For multiple output units, load regulation is given for load change of 10% to 100% with other outputs set to 60% adjustment load. 4. When V2 load is 15-100% Mechanical Details ECP40USXX ECP40UDXX / ECP40UTXX 3.50 (88.9) 3.00 (76.2) 0.374 0.4 3.25 (82.6) 2.75 (69.8) (9.5) (10.3) CN2 CN2 2.00 1 1 (50.8) 1.75 (44.5) 4 1.75 CN1 2.0 CN1 (44.5) (50.8) 3 6 0.023 3 0.023 0.12 (6.0) 0.12 (6.0) 1 1 (3.2) (3.2) 0.134 ( 3.4) Mounting holes need to be 0.12 0.12 0.134 ( 3.4) (3.2) isolated from ground (3.2) 0.06 0.86 0.79 0.06 (1.6) (22.0) (19.0) (1.6) 0.09 (2.4) 0.09 (2.4) 0.91 (23.0) Output Connector CN2 Pin 1 V2 Output Connector CN2 Pin 2 V1 Input Connector CN1 Pin 1 + Vout Input Connector CN1 Pin 3 V1 Pin 1 Neutral Pin 2 + Vout Pin 1 Neutral Pin 4 RTN Pin 2 Not Fitted Pin 3 - Vout Pin 2 Not Fitted Pin 5 RTN Pin 3 Line Pin 4 - Vout Pin 3 Line Pin 6 V3 CN1 mates with JST housing CN2 mates with JST housing CN1 mates with JST housing CN2 mates with JST housing VHR-3N and JST Series VHR-4N and JST Series VHR-3N and JST Series VHR-6N and JST Series SVH-21T-P1.1 crimp terminals. SVH-21T-P1.1 crimp terminals. SVH-21T-P1.1 crimp terminals. SVH-21T-P1.1 crimp terminals. Mounting holes marked with Mounting holes marked with must be connected to must be connected to safety earth safety earth Notes 1. All dimensions are in inches (mm). 2. Weight: ECP40USXX: 0.18 lbs (80 g) approx, ECP40UD/UTXX: 0.24 lbs (110 g) 01 Sept 2021