FCM400 Series Integral Low Noise Fan 400 W Output Power 600 W Peak Rating 500 ms Screw Terminals Class B Conducted Emissions 5 V Standby Rail 80 V - 275 VAC Input Operation IT & Medical Safety Approvals Remote On/Off & Power Fail Signal as Standard The FCM400 AC-DC power supply provides upto 400 W continuous and 600 W peak output power for up to 0.5 seconds. Packaged in a compact 6 (152 mm) x 4 (102 mm) x 1.9 (49 mm) and certified to IEC60950, IEC6238 & IEC60601 family safety approvals, the FCM400 can be easily integrated into a wide range of both industrial and medical applications. A low noise fan allows quiet operation at full power from -10 C to 50 C and 50% power at +70 C. The unit comprises of a main output with voltages from 12-48 VDC and a peripheral output providing a 5 VDC standby supply which can be utilitsed with the signals and control features of the unit to provide detection of loss of AC input and remote on/off control. xppower.com Models and Ratings Output Power Output Current V1 Output Voltage V1 Standby Supply V2 Model Number (1) (1) P nom P peak I nom I peak 400 W 600 W 12.0 VDC 33.3 A 50 A 5.0 V/0.5 A FCM400PS12 400 W 600 W 15.0 VDC 26.6 A 40 A 5.0 V/0.5 A FCM400PS15 400 W 600 W 24.0 VDC 16.6 A 25 A 5.0 V/0.5 A FCM400PS24 400 W 600 W 28.0 VDC 14.2 A 21.4 A 5.0 V/0.5 A FCM400PS28 400 W 600 W 36.0 VDC 11.1 A 16.7 A 5.0 V/0.5 A FCM400PS36 400 W 600 W 48.0 VDC 8.3 A 12.5 A 5.0 V/0.5 A FCM400PS48 Notes: 1. Peak duration is 500 ms max, average power must not exceed 400 W. Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output power <90 VAC. See fig 1. Input Voltage - Operating 80 115/230 275 VAC Power fail signal cannot be used <90 VAC. Input Frequency 47 50/60 63 Hz > Power Factor 0.9 EN61000-3-2 class A compliant Input Current - No Load 0.11/0.15 A 115/230 VAC Input Current - Full Load 4.1/2.1 A 115/230 VAC Inrush Current 60 A 230 VAC, 25C 115 VAC 60 Hz/230 VAC 50 Hz (Typ), Earth Leakage Current 100/165 260 A 264 VAC/60 Hz (Max.) Input Protection F10 A/250 V internal fuse in both line and neutral Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table (V1) (V2) Initial Set Accuracy 0.5 , 5 % 50% load, 115/230 VAC Output Voltage Adjustment 10 % V1 only via potentiometer. See mech. details (page 11). Minimum Load 0 A Start Up Delay 1 s 230 VAC full load (see fig.2) Hold Up Time 20 35 ms 90 VAC full load (see fig.3) Drift 0.2 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC (V1) (V2) Load Regulation 1 , 5 % 0-100% load. Recovery within 1% in less than 500 s Transient Response - V1 4 % for a 50-75% and 75-50% load step Over/Undershoot - V1 5 % (V1) (V2) Ripple & Noise 0.5 1 , 2 % pk-pk 20 MHz bandwidth (see fig.4 & 5) Overvoltage Protection 115 140 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 150 165 % I nom Output 1 only, auto reset (see fig.6) Short Circuit Protection Continuous (see fig. 6) Temperature Coefficient 0.05 %/C Overtemperature Protection C Auto recovery - temperature of main transformer 2