AC-DC Power Supplies XPPower GCS Series 150/180/250/350 Watts Convection/Forced-cooled Ratings Universal 85 - 264 VAC Input IT & Medical Safety Approvals (Class I & II) < 0.5 W Standby Power (150 & 180 Models) -40 C to +70 C Operation Remote On/Off Class B Emissions 3 Year Warranty Dimensions: The GCS Series has been designed to minimise the no load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. Approved GCS150/GCS180/GCS250/GCS350: 5.00 x 3.00 x 1.42 (127.0 x 76.2 x 36.3 mm) for Class I and Class II applications, this range of single output AC-DC power supplies are (-C): 5.50 x 3.48 x 1.70 (139.7 x 88.5 x 43.2 mm) packaged in an industry standard 3.0 x 5.0 x 1.42 package and achieves EN55011/32 Level (-TF): 5.50 x 3.48 x 2.20 (139.7 x 88.5 x 57.8 mm) B emissions compliance whilst maintaining very low earth leakage currents, making them (-EF): 6.35 x 3.48 x 1.70 (161.3 x 88.5 x 43.2 mm) (350-EF): 6.00 x 3.50 x 1.75 (152.4 x 88.9 x 44.4 mm) suitable for a wide range of 1U and other industrial, IT and medical applications. The series has single output versions from 12 V to 56 VDC, dual-fusing for compliance with IEC60601-1 and feature minimal excess heat generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 C and up to +70 C and are available with a number of cover options. Models & Ratings Output Current V1 Output Voltage (Vfan) (1,2,3,4,5) Output Voltage V1 Max Output Power Model Number (6,7) (8) & Current Convection-cooled Forced-cooled 12.0 VDC 9.2 A 12.5 A 12.0 VDC/0.6 A 157 W GCS150PS12 15.0 VDC 7.3 A 10.0 A 12.0 VDC/0.6 A 157 W GCS150PS15 24.0 VDC 4.6 A 6.3 A 12.0 VDC/0.6 A 157 W GCS150PS24 28.0 VDC 3.9 A 5.4 A 12.0 VDC/0.6 A 157 W GCS150PS28 48.0 VDC 2.3 A 3.2 A 12.0 VDC/0.6 A 157 W GCS150PS48 12.0 VDC 12.5 A 15.0 A 12.0 VDC/0.6 A 187 W GCS180PS12 15.0 VDC 10.0 A 12.0 A 12.0 VDC/0.6 A 187 W GCS180PS15 24.0 VDC 6.3 A 7.5 A 12.0 VDC/0.6 A 187 W GCS180PS24 28.0 VDC 5.4 A 6.4 A 12.0 VDC/0.6 A 187 W GCS180PS28 48.0 VDC 3.1 A 3.7 A 12.0 VDC/0.6 A 187 W GCS180PS48 12.0 VDC 15.0 A 18.8 A 12.0 VDC/0.6 A 232 W GCS250PS12 15.0 VDC 12.0 A 15.0 A 12.0 VDC/0.6 A 232 W GCS250PS15 24.0 VDC 7.5 A 10.4 A 12.0 VDC/0.6 A 257 W GCS250PS24 28.0 VDC 6.4 A 8.9 A 12.0 VDC/0.6 A 257 W GCS250PS28 48.0 VDC 3.7 A 5.2 A 12.0 VDC/0.6 A 257 W GCS250PS48 56.0 VDC 3.2 A 4.5 A 12.0 VDC/0.6 A 257 W GCS250PS56 (9) 12.0 VDC 16.7 A 29.2 A 12.0 VDC/0.6 A 350 W GCS350PS12 (9) 15.0 VDC 13.3 A 23.4 A 12.0 VDC/0.6 A 350 W GCS350PS15 (10) 24.0 VDC 8.3 A 14.6 A 12.0 VDC/0.6 A 350 W GCS350PS24 (10) 28.0 VDC 7.1 A 12.5 A 12.0 VDC/0.6 A 350 W GCS350PS28 (10) 48.0 VDC 4.2 A 7.3 A 12.0 VDC/0.6 A 350 W GCS350PS48 (10) 56.0 VDC 3.6 A 6.25 A 12.0 VDC/0.6 A 350 W GCS350PS56 Notes 1. Add suffix -C for convection-cooled cover, e.g. GCS150PS12-C. 5. GCS250PS12-C & GCS250PS15-C models derate 20% when convection cooled. 2. Cover kits available. Order part no.: GCS150/180 CVR KIT 6. GCS350 convection rating quoted at 40 C, others at 50 C, see thermal derating curve. 3. Add suffix -EF for fan-cooled cover with end fan e.g. GCS150PS12-EF, 7. GCS350-C models derate 15% when convection-cooled at 40 C. add suffix -TF for fan-cooled cover with top fan, e.g. GCS150PS12-TF. Note: Vfan 8. 7 CFM required to meet stated current for GCS150/180/250 and 15 CFM for GCS350. output no longer available. 9. Add suffix -J for optional dual row molex connector. See GCS350 model 4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with mechanics for details. convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers, 10. Add suffix -S for optional screw terminals. See GCS350 mechanics for details. (remote on/off is standard on GCS350 models). www.xppower.com 1AC-DC Power Supplies XPPower GCS Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 115/230 264 VAC Derate output power <90 VAC. See fig 1. Input Frequency 47 50/60 63 Hz > Power Factor 0.9 230 VAC, 100% load 1.5/0.7 GCS150: 115/230 VAC 1.8/0.8 GCS180: 115/230 VAC 2.2/1.1 GCS250 12-15 V models: 115/230 VAC Input Current - Full Load A 2.4/1.2 GCS250 24 V models: 115/230 VAC 3.6/1.8 GCS350: 115/230 VAC Inrush Current 80 A 230 VAC cold start 25 C 0.5 All GCS150 & GCS180 (including -R Models) 2.3 GCS150 & GCS180 -R Models with inhibit activated 5 All GCS250 (including -R Models) 115V AC No Load Input Power 3 W All GCS250 (including -R Models) 230V AC 1 GCS250 -R Models with inhibit activated 115V AC 3 GCS250 -R Models with inhibit activated 230V AC 4 GCS350: 115/230 VAC 60/120 200 GCS150: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. 95/185 250 GCS180: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. Earth Leakage Current A 95/185 250 GCS250: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. 95/185 250 GCS350: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. Input Protection GCS150/180: F3.15 A/250 V internal fuse in both lines. GCS250/350: F5.0 A/250 V internal fuse in both lines. Input Voltage Derating Curve Figure 1 180 250 GCS180PSxx forced-cooled Forced-cooled (24 V / 28 V / 48 V) 170 240 160 230 150 220 GCS180PSxx convection-cooled Forced-cooled (12 V / 15 V) 140 GCS150PSxx forced-cooled 210 130 200 120 190 110 180 GCS150PSxx convection-cooled Convection-cooled (All models) 100 170 90 160 0 0 85 90 100 220 230 240 250 260 264 270 85 90 100 220 230 240 250 260 264 270 Input Voltage (VAC) Input Voltage (VAC) GCS150 & GCS180 GCS250 360 340 Forced-cooled 320 300 280 260 240 220 200 Convection-cooled (at 40 C) 180 Convection-cooled (at 50 C) 160 0 85 90 100 220 230 240 250 260 264 270 Input Voltage (VAC) GCS350 www.xppower.com 2 Output Power (W) Output Power (W) Output Power (W)