AC-DC Power Supplies HDL3000 HV Series 3000 Watts High efficiency up to 92% xxx Series High power density DC outputs from 150-400VDC Programmable output voltage (0-105%) Programmable output current (0-105%) 2 I C, RS485 & RS232 interfaces Parallel operation Fully featured signals & controls 3 year warranty Dimensions: The HDL3000HV series offers users both output voltage and output current programming HDL3000: (0 105%) via resistance, voltage or digital bus in a very high efficiency, high power 6.69 x 2.52 x 11.87 (170.0 x 64.0 x 301.49 mm) including connectors density 3 kW chassis mount package. Measuring just 6.69 x 2.52 x 11.02, the HDL3000 also features active current sharing, built-in ORing diode, remote on/off and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5 V at 0.5 A or 9V at 0.3 A. Models & Ratings Output Power Output Current (1) Output Voltage V1 Ripple & Noise Efficiency Model Number High Line Low Line High Line Low Line 3000W 2000W 150VDC 20.0A 13.3A 1500mV 91% HDL3000PS150 3000W 2000W 200VDC 15.0A 10.0A 2000mV 91% HDL3000PS200 3000W 2000W 250VDC 12.0A 8.0A 2500mV 91% HDL3000PS250 3000W 2000W 300VDC 10.0A 6.7A 3000mV 92% HDL3000PS300 3000W 2000W 400VDC 7.50A 5.0A 4000mV 92% HDL3000PS400 Notes 1. Measured with 230 VAC input and full load. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC See derating curve Input Frequency 47 63 Hz Power Factor 0.98/0.95 115/230 VAC full load Input Current 19.7/14.5 A 115 VAC at 2000 W/230 VAC at 3000 W Inrush Current 43/85 A 115/230 VAC Earth Leakage Current 1 mA 264 VAC/60 Hz www.xppower.com 1AC-DC Power Supplies HDL3000 HV Series Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 150 400 VDC See Models and Ratings table. Output Trim 5.0 % By potentionmeter. Output Voltage Program 0 105 % Of rated output. Tolerance 2%. Output Current Program 0 105 % Of rated output. Tolerance 3%. Output Voltage Tolerance 2 % Includes intital set accuracy, line & load regulation Minimum Load 0A Start Up Delay 1.1 s Start Up Rise Time 350 ms At full load. Hold Up Time 10 ms At 230 VAC and full load. Line Regulation 1.0 % (V1) Load Regulation 1 /3 % V1 Standby. 0-100% load. Transient Response <1 % For a 25% step load change. See models and ratings table. Measured with 20 MHz bandwidth and using 12 twisted Ripple & Noise 1500 4000 mV pk-pk pair wire terminated with 0.1 F ceramic capacitor and 47 F electrolytic at 25 C ambient. Tracks output voltage, see application notes Overvoltage Protection Recycle AC to reset. Tolerance 7%. Internally. Overtemperature Protection Output shuts down, auto recovers. Overload Protection 105 % Rated power, constant current. Short Circuit Protection Auto recovery. Temperature Coefficient 0.02 %/C 0-50 C. Enable Output must be enabled, see application notes, power supply is shipped with enable links fitted. Current Share 8 supplies can share within 5%. If total load is less than 5% of rated load only one unit will operate. Standby Output 5 V at 0.5 A, present whenever AC is applied (9 V at 0.3 A, user selectable, by connecting VSET, Pin 6 of CN5 to CN5 GND). Output Voltage Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 0 1 2 3 4 4.5 4.8 5 0 1 23 454.5 4.8 Programming Voltage (VDC) Resistor Value (k ) V Output Current Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 0 1 2 3 4 4.5 4.8 5 0 1 23 454.5 4.8 V Programming Voltage (VDC) Resistor Value (k ) www.xppower.com 2 Resistor Value (k Resistor Value (k Output Voltage (%) Output Current (%) Output Voltage (%) Output Current (%)