HDL3000 Series AC-DC POWER SUPPLIES FAN 3000W COOLED The HDL3000 series oerff s users both output voltage and output current programming (0 105%) via resistance, voltage or I2C bus in a very high efficiency, high power density 3kW chassis mount package. Measuring just 6.69 x 2.52 x 11.02, the HDL3000 also features active current sharing, remote on/o, rff emote sense and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5V at 0.5A or 9V at 0.3A. Features High efficiency up to 93% Applications High power density DC outputs from 12-60VDC GP GP Programmable output voltage (0-105%) Industrial Robotics Lasers LED Heating Electronics Programmable output current (0-105%) GP IC interface Dimensions Parallel operation 6.69 x 2.52 x 12.48 GP Fully featured signals &controls (170.0 x 64.0 x 317.0mm) including connectors 3 year warranty Models & Ratings Output Power Output Current (1) Model Number Output Voltage Ripple & Noise Efficiency High Line Low Line High Line Low Line HDL3000PS12 2400W 1600W 12.0VDC 200.0A 166.6A 150mV 88% HDL3000PS15 2400W 1600W 15.0VDC 160.0A 133.3A 150mV 89% HDL3000PS24 3000W 2000W 24.0VDC 125.0A 83.3A 240mV 91% HDL3000PS30 3000W 2000W 30.0VDC 100.0A 66.6A 300mV 91% HDL3000PS36 3000W 2000W 36.0VDC 83.5A 55.5A 360mV 92% HDL3000PS48 3000W 2000W 48.0 VDC 62.5A 41.6A 480mV 92% HDL3000PS60 3000W 2000W 60.0 VDC 50.0A 33.3A 600mV 93% Notes: 1. Measured with 230VAC input and full load.AC-DC POWER SUPPLIES HDL3000 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC See derating curve Input Frequency 47 63 Hz Power Factor 0.98/0.95 115/230VAC full load Input Current 19.7/15.0 A 115VAC at 2000 W/230VAC at 3000W Inrush Current 43/110 A 115/230VAC Earth Leakage Current 3 mA 264 VAC/60Hz Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 60 VDC See Models and Ratings table Output Trim 5 % By potentionmeter Output Voltage Program 0 105 % Of rated output Output Current Program 0 105 % Of rated output Output Voltage Tolerance 1 % At 50% load Minimum Load 0 A Start Up Delay 1 s Start Up Rise Time 120 ms At full load Hold Up Time 10 11 ms At 230VAC and full load Line Regulation 1 % Load Regulation 1 (V1) /3 % V1 Standby. 0-100% load Transient Response <1 % For a 25% step load change See models and ratings table. Measured with 20MHz bandwidth and using 12 twisted pair wire Ripple & Noise 150 600 mV pk-pk terminated with 0.1F ceramic capacitor and 47F electrolytic at 25C ambient. Overvoltage Protection Tracks output voltage, see application notes. Recycle AC to reset. Overtemperature Protection Primary and secondary heatsinks, monitored. Output shuts down, auto recovers Overload Protection 105 Rated power, constant current. Short Circuit Protection Auto recovery. Temperature Coefficient 0.02 %/C 0-50C Remote Sense Compensates for 0.5V max voltage drop, if remote sense is not required, local sense must be used Enable Output must be enabled, see application notes, power supply is shipped with enable links fitted Current Share 5 supplies can share within 5% Standby Output 5V at 0.5A, present whenever AC is applied (9V at 0.3A, user selectable, by connecting VSET, Pin 8 of CN2 to GND) 2