AC-DC Power Supplies HHP650 Series 600/780 Watts 85 V - 305 VAC Input MIL-STD-810F Shock & Vibration -40 C to +70 C Operation SEMI F47 Compliant 6 kV Surge Rating - IEEEStdC62.41 UL508, ANSI/ISA 12.12.01 Class I, Div II Conformal Coating 3 Year Warranty The HHP650 AC-DC power supply provides upto 780 W (1000 W peak) of Dimensions: output power in a robust mechanical fan-cooled package for industrial HHP650: applications. The unit comprises of a main output with voltages from 12-48 9.99 x 4.20 x 2.50 (253.8 x 106.8 x 63.5 mm) VDC and a 5 VDC standby supply which can be utilitsed with the signals and control features of the unit to provide detection of loss of output and remote on/off control. Models & Ratings Output Current V1 Output Power V1 Output Voltage Standby (1) (1) Nom Peak Nom Peak Model Number Supply V1 <180 V >180 V <180 V >180 V <180 V >180 V <180 V >180 V 12 V 50.0 A -- 5 V / 0.2 A 607 W -- HHP650PS12 15 V 40.0 A - - 5 V / 0.2 A 607 W - - HHP650PS15 24 V 27.0 A 32.5 A 33.3 A 41.7 A 5 V / 0.2 A 657 W 780 W 800 W 1000 W HHP650PS24 28 V 23.0 A 27.9 A 28.6 A 35.7 A 5 V / 0.2 A 651 W 780 W 800 W 1000 W HHP650PS28 36 V 18.0 A 21.7 A 22.2 A 27.8 A 5 V / 0.2 A 657 W 780 W 800 W 1000 W HHP650PS36 48 V 13.5 A 16.3 A 16.7 A 20.8 A 5 V / 0.2 A 657 W 780 W 800 W 1000 W HHP650PS48 Notes 1. Peak Power available for 10 seconds maximum with a 35% duty cycle. The average power in a period should be equal or less than the nominal power. Mechanical Details Standard Terminal Block M3.5 Screw 3 Pins L 9.5mm Center Standard Terminal Block M4 Screw 6 Pins 9.5mm Center N VR 2.50 (63.54) B LED 9.99 (253.80) 2.50 63.500 A Mounting hole 8 places M3 X 0.5 PIN 11 PIN 12 0.15(3.8) Max. Penetration A A PIN 1 PIN 2 1.95 (49.50) DETAIL B Logic Connector J3 A A 4.20 (106.77) C L 3.04 (77.30) AA 0.47 (11.90) 6.31 (160.30) 0.92 (23.30) www.xppower.com 1 VO- VO+AC-DC Power Supplies HHP Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 305 VAC Derate output power 10% < 90 VAC. Input Frequency 47 50/60 63 Hz Agency approval, 47-63 Hz EN61000-3-2 class A compliant Power Factor >0.9 EN61000-3-2 class C for loads 10% Input Current - Full Load 6.5/3.2 A 115/230 VAC Inrush Current 60 A 305 VAC cold start, 25 C Earth Leakage Current 1.5 mA 305 VAC/60 Hz Input Protection T16 A / 250 V internal in-line fuse Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table (V1) (V Standby) Initial Set Accuracy 1 , 5 % 50% load, 115/230 VAC Output Voltage Adjustment 10 % V1 only. See mechanical details. Minimum Load 0A Start Up Delay 500 ms Hold Up Time 20 ms 90 VAC Drift 0.2 % After 20 min warm up Line Regulation 0.5 % (V1) (V Standby) Load Regulation 1 , 5 % 0-100% load. Recovery within 1% in less than 500 s Transient Response - V1 4% for a 50-75%-50% load change Ripple & Noise 1 % pk-pk V1: 20 MHz bandwidth Overvoltage Protection 115 145 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 110 175 % Output 1 only, auto reset. See fig 1. Short Circuit Protection Trip & restart (hiccup mode) Overtemperature Protection 100 C Auto reset. Input & output stage protection Temperature Coefficient 0.05 %/C Overtemperature Protection C Protects unit from overtemperature. Auto reset. Output Overload Characteristics Figure 1 100 Trip & Restart 75 50 25 0 200 400 600 800 1000 1200 1400 Output Power (W) www.xppower.com 2 Output Voltage (%)