HPL5K0 Series AC-DC POWER SUPPLIES FAN 5000W COOLED The HPL5K0 series oerff s ultimate flexibility with both output voltage and output current programming and user defined signals, warnings and alarms. Programming is via voltage, IC PMBus, RS485 and CANopen in a very high efficiency, high power density 5kW chassis mount package. The HPL5K0 can be used in both constant voltage and constant current operation. Options are available for RS232 or UART. Measuring just 13.0 x 5.0 x 5.0, the HPL5K0 also features active current sharing, remote on/o, rff emote sense and a power OK signal. The 5V/2A standby output is available whenever the mains supply is present. Applications Features 3 Phase 180 to 264 VACinput - 3 wire &earth High efficiency - up to 93% Healthcare Semiconductor Technology Industrial Manufacturing Electronics Programmable output voltage (0-105%) Programmable output current (0-110%) Dimensions Parallel operation Analog and digital interfaces HPL5K0: 13.00 x 5.00 x 5.00 in (330.2 x 127.0 x 127.0 mm) Multiple digital protocols - PMBus, CANopen, MODBUS &SCPI Fully featured signals &controls 5V/2A standby output Graphical user interface (GUI) 3 year warranty Models & Ratings Output Voltage V1 Output Current Max (1,2) (3) Model Number Efficiency Output Power Minimum Nominal Maximum Minimum Maximum HPL5K0TS060 5000W 0 VDC 60 VDC 63 VDC 0.0A 83.3 A 92% HPL5K0TS100 5000W 0 VDC 100 VDC 105 VDC 0.0A 50.0 A 92% HPL5K0TS200 5000W 0 VDC 200 VDC 210 VDC 0.0A 25.0 A 92% Notes: 1. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full duplex. RS485 half duplex can be configured via I 2C or factory configured on request. To replace RS485 with RS232 or UART, contact sales. 2. For medical applications with 4000 VAC isolation test add suffix -M. Installation Class 3 surge only. 3. Measured with 180 VAC input and full load. 4. USBinterface available to enable RS485 and RS232 communication with GUI, part number XPPSMANAGERINT.AC-DC POWER SUPPLIES HPL5K0 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 180 264 VAC 5kW output power max, 3 wire & earth Input Frequency 47 63 Hz Power Factor 0.98 Complies with EN61000-3-2 for Class A Input Current 18 A Per phase, 180VAC (5 kW) Inrush Current 60 A Per phase, 264VAC (5 kW), cold start 25C 1.0 528VAC/60Hz Earth Leakage Current mA 3.3 528VAC/60Hz, single fault Input Protection F25A / 250V fuse fitted in each phase Loss of phase Shut down after 0.5s, auto-recovery Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 0 210 VDC See Models and Ratings table Output Set Tolerance 0.5 % Nominal voltage irrespective of set voltage. +5 V Standby Tolerance 3 % 5V/2A Standby Of nominal, slew rate <40ms 10-105% & 105-10%. Output Voltage Program 0 105 % Max frequency of voltage program is 0.5Hz 0-5% load, 0.67Hz 5-10% load, 1Hz 10-20% load, 3Hz 20-100% load Output Voltage Adjust 10 % Of set output via potentiometer 105% of nominal max. Output Current Program 0 110 % Of nominal Minimum Load 0 A No minimum load required Start Up Delay 1.8 2.3 s Under all load and line conditions Start Up Rise Time 40 ms Hold Up Time 20 22 ms 208VAC at 5000 W and 25C 0.5 Of nominal voltage Line Regulation % 0.5 5V/2A Standby 1 0-100% or 100-0% load Load Regulation % 2 5V/2A Standby Deviation with a 50-75-50% load change. Output returns to within Transient Response 3 % 1% in less than 500s Of nominal voltage/5V Standby. Measured with 20 MHz bandwidth Ripple & Noise 1/2.5 % limited oscilloscope 0-50C. Overshoot 5 % Turn on & turn off Of nominal voltage, latching. Cycle AC to reset. No protection for Overvoltage Protection 120 % 5V Standby Overtemperature Protection Auto resetting thermal protection Set current limit point. Constant current characteristics. % of Overload Protection 3 Max current limit is 108% 3% of maximum rated current. max load <5A max Temperature Coefficient 0.03 of max load %/C Short Circuit Protection Constant current characteristics. 5V/2A Standby: Foldback characteristic <5A max Remote Sense Compensates for 1% max of nominal voltage per lead, 2% of total nominal voltage drop. Not fitted on HPL5K0TS200 5V Standby Supply 5V/2A standby supply, available whenever the mains supply is present 2