HPT5K0-L Series AC-DC POWER SUPPLIES FAN 5000W COOLED The HPT5K0-L series oerff s ultimate flexibility with both output voltage and output current 2 programming and user defined signals, warnings & alarms. Programming is via voltage, I C PMBus, RS485 and CANopen in a very high efficiency, high power density 5 kW chassis mount package. Options are available for RS232 or UART. The HPT-L can be used in both constant voltage and constant current operation. Measuring just 13.25 x 10.00 x 2.50 the HPT5K0-L also features active current sharing, remote on/o, rff emote sense and a power OK signal. The standby output is available whenever the mains supply is present. Applications Features 3 phase 180 to 528 VACinput - 3 wire &earth High efficiency - up to 94% Healthcare Technology Semiconductor Industrial Manufacturing Electronics Programmable output voltage (0-105%) Programmable output current (0-110%) Dimensions Parallel operation Analog & digital interfaces HPT5K0-L: 13.25 x 10.00 x 2.50 in (336.5 x 254.0 x 63.5 mm) Multiple digital protocols - PMBus, CANopen, MODBUS &SCPI Fully featured signals &controls 5V/2A standby output Graphical User Interface (GUI) 3 Year Warranty Models & Ratings Output Voltage V1 Output Current Max (2,3) (1) Model Number Efficiency Output Power Minimum Nominal Maximum Minimum Maximum HPT5K0TS060-L 5000W 0VDC 60VDC 63VDC 0.0A 83.3A 93% HPT5K0TS100-L 5000W 0VDC 100VDC 105VDC 0.0A 50.0A 93% HPT5K0TS200-L 5000W 0VDC 200VDC 210VDC 0.0A 25.0A 93% Notes: 1. Measured with 480 VAC input and full load. 2 2. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full duplex. RS485 half duplex can be configured via I C or factory configured on request. To replace RS485 with RS232 or UART, contact sales. 3. For medical applications with 4000 VAC isolation test add suffix -M. Installation Class 3 surge only. 4. USBinterface available to enable RS485 and RS232 communication with GUI, part number XPPSMANAGERINT.AC-DC POWER SUPPLIES HPT5K0-L Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions 180 264 3kW output power max, 3 wire & earth Input Voltage 342 528 VAC 5kW output power max, 3 wire & earth 580 For 5 s Input Frequency 47 63 Hz Power Factor 0.96 Complies with EN61000-3-2 for Class A Input Current 10/11 A Per phase, 342VAC (5 kW)/180 VAC (3kW) Inrush Current 60 A Per phase, 528VAC (5 kW) 1.0 528 VAC/60Hz Earth Leakage Current mA 3.3 528 VAC/60Hz, single fault Input Protection F16A / 500 V fuse fitted in each phase Loss of Phase Shut down after 0.5s, auto-recovery Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 0 210 VDC See Models and Ratings table Output Set Tolerance 0.5 % Nominal voltage irrespective of set voltage. +5 V Standby Tolerance 4 % 5V/2A Standby Of nominal, slew rate <40 ms 10-105% & 105-10%. Output Voltage Program 0 105 % Max frequency of voltage program is 0.5 Hz 0-5% load, 0.67 Hz 5-10% load, 1Hz 10-20% load, 3 Hz 20-100% load Output Voltage Adjust 10 % Of set output via potentiometer 105% of nominal max. Output Current Program 0 110 % Of nominal Minimum Load 0 A No minimum load required Start Up Delay 2.0 2.3 s Under all load and line conditions Start Up Rise Time 40 ms 20 22 380 VAC at 5000 W and 25C Hold Up Time ms 40 44 180 VAC at 3000 W and 25C 0.5 Of nominal voltage Line Regulation % 0.5 5V Standby 1 0-100% or 100-0% load Load Regulation % 2 5V Standby Deviation with a 50-75-50% load change. Output returns to within Transient Response 3 % 1% in less than 500s Of nominal voltage/5V Standby. Measured with 20 MHz bandwidth Ripple & Noise 1/2.5 % limited oscilloscope 0-50C. Overshoot 5 % Turn on & turn off Of nominal voltage, latching. Cycle AC to reset. No protection for Overvoltage Protection 110 120 % 5V Standby Overtemperature Protection Auto resetting thermal protection Set current limit point. Constant current characteristics. Max current % of limit is 108% 3% of maximum rated current. For low line (180- Overload Protection 3 max load 264VAC), constant power characteristic set at 3.4W until current limit point is reached. 5V Standby: <5A max Temperature Coefficient 0.03 of max load %/C Short Circuit Protection Constant current characteristics. 5V Standby: Foldback characteristic < 5A max. Remote Sense Compensates for 1% max of nominal voltage per lead, 2% of total nominal voltage drop. Not fitted on HPT5K0-LTS200 2