2 Watts xppower.com JAH Series Low Cost DIP-24 Package Operating Temperature -40 C to +100 C Single & Dual Outputs Optional Metal Case Optional Isolation to 6000 VDC 3 Year Warranty Specification Input General Input Voltage Range Nominal 10% Efficiency See tables Input Current See table Isolation 1000 VDC input to output, for optional high isolation versions up to 6000 VDC input to Input Filter Pi network output (see note 1) 60s test. Input Reverse Voltage None 1000 VDC input to case Protection 1000 VDC output to case Undervoltage Lockout None 9 Isolation Resistance 10 Input Reflected Ripple 35 mA pk-pk through 12 H inductor, Switching Frequency 40 kHz typical singles, 5 Hz to 20 MHz 300 kHz typical duals Input Surge 5 V models 7 VDC for 100 ms 3 Power Density 5.21 W/in 12 V models 15 VDC for 100 ms MTBF >3 MHrs to MIL-HDBK-217F at 25 C, GB 24 V models 28 VDC for 100 ms Output Environmental Output Voltage See table Operating Temperature -40 C to +100 C, derate from 100% load Minimum Load No minimum load required at +85 C to no load at +100 C Initial Set Accuracy 2% max Case Temperature +100 C max Start Up Delay 20 ms typical Storage Temperature -40 C to +125 C Start Up Rise Time 20 ms typical Humidity Up to 90%, non-condensing Line Regulation 0.5% max Cooling Natural convection Load Regulation 0.5% max single & dual models (1.0% max for 3V3 versions) (see note 6) Cross Regulation 5% on dual output models (see note 4) EMC & Safety Transient Response 3% max deviation (5% for 3V3 output), Emissions EN55032 class A, conducted & radiated recovery to within 1% in 2 ms for a 50% with external components load change (see Application Notes) Ripple & Noise 75 mV pk-pk measured with ESD Immunity EN61000-4-2, level 3, Perf Criteria A 20 MHz bandwidth EFT/Burst EN61000-4-4, level 3, Perf Criteria A Short Circuit Protection Output shuts down with auto recovery (see note 5) Maximum Capacitive See tables Surge EN61000-4-5, installation class 2, Load Perf Criteria A (see note 5) Temperature 0.02/C max Conducted Immunity EN61000-4-6, 10 Vrms, Perf Criteria A Coefficient Magnetic Fields EN61000-4-8, 1 A/m, Perf Criteria A Safety Approvals CE (Meets all applicable directives), UKCA (Meets all applicable legislation) DC-DCDC-DC JAH02 Models and Ratings (2) Input Output Output Input Current Maximum (1,3) Efficiency Model Number Voltage Voltage Current No Load Full Load Capacitive Load 3.3 V 500 mA 75 mA 622 mA 330 F 53% JAH0205S3V3 5.0 V 400 mA 75 mA 615 mA 330 F 65% JAH0205S05 9.0 V 222 mA 75 mA 597 mA 330 F 67% JAH0205S09 12.0 V 166 mA 75 mA 571 mA 330 F 70% JAH0205S12 15.0 V 133 mA 75 mA 588 mA 330 F 68% JAH0205S15 24.0 V 83 mA 75 mA 615 mA 330 F 65% JAH0205S24 5 V 3.3 V 300 mA 30 mA 638 mA 1000 F 62% JAH0205D03 5.0 V 200 mA 30 mA 588 mA 1000 F 68% JAH0205D05 9.0 V 111 mA 40 mA 571 mA 470 F 70% JAH0205D09 12.0 V 83 mA 40 mA 571 mA 470 F 70% JAH0205D12 15.0 V 67 mA 40 mA 571 mA 470 F 70% JAH0205D15 24.0 V 42 mA 50 mA 579 mA 220 F 69% JAH0205D24 3.3 V 500 mA 70 mA 245 mA 330 F 56% JAH0212S3V3 5.0 V 400 mA 70 mA 260 mA 330 F 64% JAH0212S05 9.0 V 222 mA 70 mA 245 mA 330 F 68% JAH0212S09 12.0 V 166 mA 70 mA 238 mA 330 F 70% JAH0212S12 15.0 V 133 mA 70 mA 252 mA 330 F 66% JAH0212S15 24.0 V 83 mA 70 mA 256 mA 330 F 65% JAH0212S24 12 V 3.3 V 300 mA 20 mA 250 mA 1000 F 66% JAH0212D03 5.0 V 200 mA 20 mA 228 mA 1000 F 73% JAH0212D05 9.0 V 111 mA 20 mA 222 mA 470 F 75% JAH0212D09 12.0 V 83 mA 20 mA 213 mA 470 F 78% JAH0212D12 15.0 V 67 mA 35 mA 216 mA 470 F 77% JAH0212D15 24.0 V 42 mA 35 mA 219 mA 220 F 76% JAH0212D24 3.3 V 500 mA 25 mA 120 mA 330 F 57% JAH0224S3V3 5.0 V 400 mA 25 mA 132 mA 330 F 63% JAH0224S05 9.0 V 222 mA 25 mA 132 mA 330 F 63% JAH0224S09 12.0 V 166 mA 25 mA 122 mA 330 F 68% JAH0224S12 15.0 V 133 mA 25 mA 122 mA 330 F 68% JAH0224S15 24.0 V 83 mA 25 mA 122 mA 330 F 68% JAH0224S24 24 V 3.3 V 300 mA 15 mA 121 mA 1000 F 68% JAH0224D03 5.0 V 200 mA 15 mA 114 mA 1000 F 73% JAH0224D05 9.0 V 111 mA 15 mA 111 mA 470 F 75% JAH0224D09 12.0 V 83 mA 15 mA 104 mA 470 F 80% JAH0224D12 15.0 V 67 mA 20 mA 108 mA 470 F 77% JAH0224D15 24.0 V 42 mA 20 mA 111 mA 220 F 75% JAH0224D24 Notes 1. For optional 3000 VDC isolation add suffix -H to model number. 4. Cross regulation is 5% when one output is at 100% and the other is varied For optional 4000 VDC isolation add suffix -H4 to model number. between 25% and 100%. For optional 5000 VDC isolation add suffix -H5 to model number. 5. A 220 F/250 V capacitor across the input is required in order to meet For optional 6000 VDC isolation add suffix -H6 to model number. EN61000-4-4 and EN61000-4-5. 2. Input current measured at nominal input voltage. 6. Dual output regulation is specified with a balanced load. 3. For optional metal case add suffix -M. Metal case is only an option up to 3000 VDC isolation versions eg. JAH0212S15-HM. Mechanical Details 0.01 0.90 PIN CONNECTIONS 1.25 (31.75) (0.25) (22.86) Pin Single Dual Single -H Dual -H 1 +Vin +Vin +Vin +Vin 1213 0 1112 2 N.C. -Vout +Vin +Vin 0.80 Bottom View 0.60 3 N.C. Common N.P N.P (20.32) (15.24) 10 -Vout Common N.P Common 24 23 22 15 14 13 11 +Vout +Vout N.P Common 12 -Vin -Vin -Vout N.P 0.02 0.20 13 -Vin -Vin +Vout -Vout (0.50) (5.08) 14 +Vout +Vout N.P N.P 0.40 15 -Vout Common N.P +Vout (10.16) 22 N.C. Common N.P N.P 0.12 (3.05) Min. 23 N.C. -Vout -Vin -Vin 24 +Vin +Vin -Vin -Vin Application Notes N.P : No Pin N.C : No Connection Input Filter +Vout Notes +Vin + 1. All dimensions are in inches (mm) L1 Single Output Models Dual Output Models DC/DC C1 2. Weight: Plastic Case: 0.028 lbs (12.5 g), Load C1 L1 C1 L1 Converter Metal Case: 0.033 lbs (15.0 g) 220 F/100 V 12 H 220 F/100 V 22 H 3. Pin diameter: 0.020.002 (0.50.05) - -Vin -Vout 4. Pin pitch tolerance: 0.014 (0.35) 5. Case tolerance: 0.02 (0.5) 29 Sept 2021