xppower.com 80 160 Watts JPM Series Output Voltages from 3.3 to 48 VDC Power Factor Corrected Suitable for Battery charging Applications Low Ripple & Noise 125% Rating at 230 VAC Optional Remote On/Off 3 Year Warranty Specification Input General Input Voltage 85-264 VAC (120-370 VDC) Efficiency See tables Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Input Current 0.7 A max at 230 VAC (JPM80) 500 VAC Output to Ground 1.1 A max at 230 VAC (JPM120) 1.4 A max at 230 VAC (JPM160) MTBF >183 kHrs to MIL-HDBK-217F at 25 C, GB Inrush Current 40 A at 230 VAC cold start Switching Frequency PFC 67 kHz, PWM 134 kHz typical Power Factor >0.9 Signals DC OK Green LED Earth Leakage Current <2 mA at 230 VAC Remote On/Off Input Protection F4 A/250 VAC (JPM80) F5 A/250 VAC (JPM120, JPM160) Environmental Operating Temperature -10 C to +60 C, see derating curves Output Cooling JPM80 & JPM120 convection-cooled, Output Voltage See tables JPM160 includes internal fan Output Voltage Trim +10%, -5% Operating Humidity 20-90% RH, non-condensing Initial Set Accuracy 2% Storage Temperature -20 C to +85 C Start Up Delay 600 ms max Vibration 2 g, 10-500 Hz, 10 min/cycle for 60 Start Up Rise Time 30 ms max minutes each axis Hold Up Time 25 ms min Line Regulation 0.5% EMC & Safety Load Regulation See tables Emissions EN55022 (CISPR22), level A conducted Ripple & Noise See tables EN55022 (CISPR22), level B radiated Overvoltage Protection 110-135% Vnom, recycle input to reset Harmonic Currents EN61000-3-2 Overtemperature Shuts down at +95 C 5 C (measured Voltage Flicker EN61000-3-3 Protection internally) with auto recovery, (JPM120 ESD Immunity EN61000-4-2, level 3 Perf Criteria A and JPM160) Radiated Immunity EN61000-4-3, 3 V/m Perf Criteria A Overload Protection 105-150% constant current, auto recovery EFT/Burst EN61000-4-4, level 2 Perf Criteria A Temperature 0.05%/C Surge EN61000-4-5, level 3 Perf Criteria A Coefficient Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Remote On/Off 4-10 VDC On, <0.8 VDC Off, optional. Magnetic Field EN61000-4-8, 3 A/m Perf Criteria A Add suffix -R to model number Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, >95% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1, UL60950-1, CSA22.2 No. 60950-1, CE Mark LVD AC DCAC DC LOAD % (180-264 VAC Input) JPM80 Models and Ratings (3) Output Output Output Ripple & Noise Load Model Efficiency (1,2) Power Voltage Current (pk-pk) Regulation Number 53 W 3.3 V 16.0 A 100 mV 1.0% 70% JPM80PS03 80 W 5.0 V 16.0 A 100 mV 1.0% 76% JPM80PS05 80 W 7.5 V 10.7 A 100 mV 1.0% 78% JPM80PS07 80 W 12.0 V 6.8 A 100 mV 0.5% 80% JPM80PS12 80 W 13.5 V 6.0 A 100 mV 0.5% 80% JPM80PS13 80 W 15.0 V 5.3 A 100 mV 0.5% 82% JPM80PS15 80 W 24.0 V 3.4 A 150 mV 0.5% 84% JPM80PS24 80 W 27.0 V 3.0 A 150 mV 0.5% 83% JPM80PS27 80 W 48.0 V 1.7 A 250 mV 0.5% 82% JPM80PS48 Notes 1. Max output increases to 125% of rated power when input voltage is between 180 VAC and 264 VAC - see derating curve below. 2. Mounting vertically increases max ambient temperature. See derating curve. 3. Ripple and noise measured at 20 MHz bandwidth using a 12 inch twisted wire pair, terminated with a 0.1 F and a 47 F capacitor connected in parallel. 4. To attach the power supply to a DIN rail, order 2 x DIN CLIP. Mechanical Details All dimensions in inches (mm) 7.05 (179.1) Tolerance: 0.03 (0.8 max) 0.79 1.00 4.84 (122.9) Weight: 1.3 lb (600 g) approx. (20.1) (25.4) Maximum mounting screw penetration: 1.00 4.6 (116.8) 0.12 (3 mm) from base outer surface, (25.4) 2.36 2.56 (65.0) 0.24 (6 mm) from side outer surface. (60.0) Input and output terminal screw tightening torque: 2 x M4 L = 3 mm 9 lbs-in (1.0 Nm) maximum. J2 (optional) LED +V 2.01 ADJ. 7 (51.1) 3.11 6 (79.0) 0.37 Vertical (9.5) 3.90 5 Orientation J1 (99.1) 4 4.69 1.95 (119.1) 3 (49.5) 0.31 1.5 2 (8.0) (38.1) 1 0.4 (10.2) 0.62 5 x M3 L=3mm (16.0) 0.16 (4.0) Function Conn Pin 4 x optional fixing lugs p/n JPMFL 0.6 0.24 (6.0) 1 AC Input (15.0) 2 AC Input 0.43 5.59 (142.0) 3 Ground (11.0) 1.00 (25.4) 4 DC Output -V J1 5 DC Output -V 6 DC Output +V 7 DC Output +V Horizontal 9.5mm pitch M4 barrier strip 0.59 Orientation 1 Remote On/Off + (15.0) Opt 2 Remote On/Off - J2 Molex type 22-23-2021 compatible 0.50 4 x M4 L=6mm (12.7) Derating Curve 100 125 80 100 60 75 40 50 20 25 12 V TO 48 V CONVECTION -10 10 40 50 55 60 (HORIZONTAL) 3 V TO 7 V WITH 18 CFM 0 20 30 55 70 (VERTICAL) 3 V TO 7 V WITH CONVECTION AMBIENT TEMPERATURE C LOAD % (85-180 VAC Input) 1.00 (25.4) 1.00 (25.4) 1.77 (45.0)