xppower.com 250/350 Watts JPS250/350 Series 200 W / 300 W with Convection Cooling High Efficiency up to 88% Meets 1U, Low Profile Requirements AC OK & DC OK Signals Zero Voltage Switching Technology Remote On/Off & Remote Sense 3 Year Warranty Specification Input General Input Voltage 85-264 VAC (170-370 VDC) Efficiency Up to 88% Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Input Current 2.75 A/1.40 A max at 115 VAC/ 230 VAC (JPS250) 500 VAC Output to Ground 4.5 A/2.2 A max at 115 VAC/230 VAC (JPS350) Switching Frequency 120 kHz typical for PFC and PWM Inrush Current 30 A at 115 VAC, 60 A at 230 VAC 3 Power Density 4.96 W/In Power Factor 0.9 typical Signals AC OK, DC OK, Remote On/Off Earth Leakage Current 3.0 mA max 264 VAC/60 Hz (see control and supervisory signals) Input Protection Internal T5 A, 250 VAC fuse (JPS250) MTBF 125 kHrs to MIL-HDBK-217F Internal T6.3 A, 250 VAC fuse (JPS350) at +50 C, GB (JPS250) 146 kHrs to MIL-HDBK-217F Output at +50 C, GB (JPS350) Output Voltage See tables Output Voltage Trim 10% on output 1 only (VR1) Environmental Initial Set Accuracy At 60% rated load 1% on V1 & V2, 5% on V3 & V4 Operating Temperature 0 C to +70 C, (see derating curve) Minimum Load Single output models: No minimum load Full power to +50 C required. Multi-output models, see note 4 Cooling 250 W with 18 CFM airflow (JPS250) Start Up Delay 2 s typical 200 W convection cooling (JPS250) Start Up Rise Time 80 ms typical (JPS250) 350 W with 18 CFM airflow (JPS350) 300 W convection cooling (JPS350) 100 ms typical (JPS350) Hold Up Time 20 ms min at low line & rated load Operating Humidity 5-95% RH, non-condensing Storage Temperature -20 C to +85 C Line Regulation 0.5% at rated load across input voltage range Load Regulation 1% for single output models & V1 & V2 of Operating Altitude 2000 m multi-output models, 5% for V3 & V4 Vibration 2 g, 10 Hz to 55 Hz, 30 mins each axis Transient Response 4% max deviation, recovery to within EMC & Safety 1% in 500 s for a 25% load change Ripple & Noise 1% max pk-pk, 15 MHz bandwidth, Emissions EN55022, level B conducted see note 2 under model tables FCC 20780, level B conducted Overvoltage Protection 115-140% on single outputs & V1 of quad Harmonic Currents EN61000-3-2 output models, recycle input to reset ESD Immunity EN61000-4-2, level 3 Perf Criteria A Overtemperature Shuts down at +110 C, auto recovery, Radiated Immunity EN61000-4-3, 10 V/m Perf Criteria A Protection measured internally EFT/Burst EN61000-4-4, level 3 Perf Criteria A Overload Protection 110-130% of max rated load on all O/Ps, Surge EN61000-4-5, level 3 Perf Criteria A auto recovery Dips and Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, Short Circuit Protection Trip and restart (Hiccup mode), auto 100% 5000 ms, Perf Criteria A, B, B recovery Safety Approvals EN60950-1, UL60950-1, Temp. Coefficient 0.05%/C CSA C22.2 No. 60950-1, CE Mark LVD Remote Sense Compensates for up to 0.5 V drop Remote On/Off On = Logic Low or Open, Off = Logic High Current Share Current share on single output models & V1 & V2 of multi-output models (4 supplies can be paralleled) Fan Output See mechanical notes for ordering information AC DCAC DC JPS250 Single Output Models and Ratings Output Current Output Output Ripple & Noise Model (1) (3) Power Voltage Pk-Pk Number Convection-cooled 18 CFM 225 W 5 V 36.0 A 45.0 A 50 mV JPS250PS05C 12 V 17.0 A 21.0 A 120 mV JPS250PS12C 15 V 13.5 A 17.0 A 120 mV JPS250PS15C 250 W 24 V 8.5 A 10.4 A 200 mV JPS250PS24C 48 V 4.3 A 5.2 A 200 mV JPS250PS48C Notes 1. Maximum power with 18 CFM forced air is 250 W, or 200 W with convection cooling. 2. Ripple and noise measured over 15 MHz bandwidth with a 0.47 F capacitor. 3. For non-current share version delete suffix C from model number. Mechanical Details All models (except JPS250PS05) 8.00 (203.2) PIN CONNECTIONS TB2 TB4 A B B A Pin VR1 JPS250PS05 All other models All models 10 L TB4 2 N Voltage Adj. 1 1 +5 V +V Signal 0 V + E TB3 - 2 +5 V +V DC OK TB1 1 3.75 4.20 3 0 V +V AC OK (95.3) (106.7) 4 0 V 0 V Remote On/Off TB2 TRANSFORMER 5 0 V 0 V +Sense 6 6 0 V 0 V -Sense A B B A (5) 7 +5 V Current Share 8 +5 V N/C 5.50 (139.0) 6.50 (165.1) 9 N/C 10 N/C 0.30 7.40 (188.0) (7.6) A A 1.51 Notes B (38.3) B 0.75 (19.1) 1. TB3 is for fan, with Molex 5045-02A or equivalent. 5 V model: 5 V at 390 mA, 24 V model: 24 V at 80 mA, 0.36 all other models: 12 V at 112 mA (9.1) 2. TB1 (AC input) and TB2 (DC output) are terminal blocks. 3. TB4 signal connector is Molex 70246-10 or equivalent. 4. Fan cover option available, order part number: 5 V models: JPS250 F/CVR 5 12, 15 & 48 V models: JPS250 F/CVR 24 V models: JPS250 F/CVR 24 JPS250PS05 Or add suffix -E to model number to receive unit with fan cover fitted. 4.2 x 8 x 2.48 (106.7 x 203.2 x 62.9). 5. For current share operation connect current share (pin 7) between 8.00 (203.2) units. For non C models pin 7 (current share) is not used. 6. Input and output terminal screw tightening torque 9 lbs-in (1.0 Nm) VR1 2 10 A B maximum. TB4 L Voltage Adj. 1 N 1 E Fixing Holes: TB1 A = 6-32 screw mounting holes 3.75 4.20 (95.3) B = M3 x 0.5 screw mounting holes (106.7) TB2 Maximum mounting screw penetration is 0.16 (4.0) from chassis TRANSFORMER outer surface. + TB3 - 8 A A B B All dimensions are in inches (mm) Tolerance: 0.03 (0.8) max 1.30 (32.1) 5.50 (139.0) 0.70 (19.1) 6.50 (165.1) Weight: 1.65 lbs (750 g) approx.