xppower.com 30 Watts JTL Series 4:1 Input Range High Power Density Single, Dual and Triple Outputs High Efficiency Up to 91% Remote On/Off 1600 VDC Isolation 3 Year Warranty Specification Input General Input Voltage Range 24 V (9-36 VDC), 48 V (18-75 VDC) Efficiency See table Input Current See table Isolation Voltage 1600 VDC Input to Output Input Reflected Ripple 20 mA pk-pk through 12 H inductor 1600 VDC Input to Case Input Filter Pi network 1600 VDC Output to Case Undervoltage Lockout 24 V models: ON 8.6 V, OFF 7.9 V typical Switching Frequency 330 kHz typical 48 V models: ON 17.8 V, OFF 16 V typical 3 Power Density 37.5 W/in Input Surge 24 V models 50 VDC for 100 ms MTBF 320 kHrs min to MIL-HDBK-217F 48 V models 100 VDC for 100 ms at 25 C, GB Output Environmental Output Voltage See table Output Voltage Trim 10% on single outputs models only Operating Temperature -40 C to +75 C, see derating curve Minimum Load No minimum load required for single and Case Temperature +105 C max dual output models, 10% required on all Cooling Convection-cooled outputs for triple output models Operating Humidity 5-95% RH, non-condensing Line Regulation 0.2% max for single and dual output models, 1.0% main, 5% auxiliary for Storage Temperature -40 C to +125 C triple output models Load Regulation Single output models: 0.5% max Dual output models: 1% max EMC balanced outputs Triple output models: 1% max main, 5% Emissions EN55022, class A conducted & auxiliaries radiated with external components, Cross Regulation 5% for dual and triples output (see note 2) see application note Setpoint Accuracy 1% (5% for triple auxiliaries) ESD Immunity EN61000-4-2, level 3, Perf Criteria A Start Up Time 30 ms typical Radiated Immunity EN61000-4-3 10 V/m Perf Criteria A* Ripple & Noise 100 mV or 1% pk-pk, whichever is greater EFT/Burst EN61000-4-4 level 3, Perf Criteria A* single & dual output models, 50/75 mV Surge EN61000-4-5 installation class 2, pk-pk main/auxiliary outputs of triple output models, 20 MHz bandwidth (see note 3) Perf Criteria A Transient Response 3% max deviation, recovery to within Conducted Immunity EN61000-4-6 10 V/rms, Perf Criteria A 1% in <250 s for a 25% load change Magnetic Field EN61000-4-8 1 A/m, Perf Criteria A Temp. Coefficient 0.02%/C Overvoltage Protection 3.3 V models: 3.9 V typical *External input capacitor required 220 F/250 V 5 V models: 6.2 V typical 12 V models: 15 V typical 15 V models: 18 V typical 5 V models: 6.2 V typical 12 V models: 15 V typical 15 V models: 18 V typical Overload Protection >150% of full load Short Circuit Protection Trip & restart (hiccup mode), auto recovery Overtemperature 115 C typical Protection Remote On/Off On = Logic High (>3.0) or Open Off = Logic Low (<1.2 V) or short pin 2 to 3 Maximum Capacitive See table Load DC DCDC DC JTL30 Models and Ratings (1) Input Current Maximum Input Voltage Output Voltage Output Current Efficiency Model Number No Load Full Load Capacitive Load 3.3 V 7.50 A 60 mA 1185 mA 20000 F 89% JTL3024S3V3 5.0 V 6.00 A 100 mA 1420 mA 14000 F 91% JTL3024S05 12.0 V 2.50 A 30 mA 1436 mA 2000 F 90% JTL3024S12 15.0 V 2.00 A 30 mA 1420 mA 2000 F 91% JTL3024S15 5.0 V 3.00 A 120 mA 1437 mA 3000 F 90% JTL3024D05 9-36 VDC 12.0 V 1.25 A 30 mA 1453 mA 1300 F 89% JTL3024D12 15.0 V 1.00 A 40 mA 1437 mA 1300 F 89% JTL3024D15 +3.3 V, 12.0 V 5.00 A, 0.42 A 80 mA 1287 mA 15000, 220 F 89% JTL3024T0312 +3.3 V, 15.0 V 5.00 A, 0.33 A 90 mA 1279 mA 15000, 220 F 89% JTL3024T0315 +5.0 V, 12.0 V 4.00 A, 0.42 A 100 mA 1440 mA 8000, 220 F 89% JTL3024T0512 +5.0 V, 15.0 V 4.00 A, 0.33 A 110 mA 1431 mA 8000, 220 F 90% JTL3024T0515 3.3 V 7.50 A 50 mA 593 mA 20000 F 89% JTL3048S3V3 5.0 V 6.00 A 60 mA 702 mA 14000 F 91% JTL3048S05 12.0 V 2.50 A 30 mA 718 mA 2000 F 90% JTL3048S12 15.0 V 2.00 A 30 mA 710 mA 2000 F 90% JTL3048S15 5.0 V 3.00 A 70 mA 710 mA 3000 F 91% JTL3048D05 18-75 VDC 12.0 V 1.25 A 30 mA 718 mA 1300 F 90% JTL3048D12 15.0 V 1.00 A 40 mA 718 mA 1300 F 90% JTL3048D15 +3.3 V, 12.0 V 5.00 A, 0.42 A 50 mA 663 mA 15000, 220 F 89% JTL3048T0312 +3.3 V, 15.0 V 5.00 A, 0.33 A 50 mA 640 mA 15000, 220 F 89% JTL3048T0315 +5.0 V, 12.0 V 4.00 A, 0.42 A 60 mA 712 mA 8000, 220 F 91% JTL3048T0512 +5.0 V, 15.0 V 4.00 A, 0.33 A 50 mA 707 mA 8000, 220 F 90% JTL3048T0515 Notes 1. Input current specified at nominal 24 V or 48 V input. 3. Measured with 1 F ceramic capacitor across output rails. 2. Cross regulation for duals is 5% when one output is at 100% and the other is 4. For heatsink option add -HK to the end of the part number. varied between 25% and 100%. Cross regulation for triples is 5% when main output and one auxiliary is at 25% and the other is varied between 25% and 100%. Mechanical Details Optional heatsink (-HK) 1.00 (25.4) 0.20 0.30 0.10 0.40 0.40 0.10 0.64 0.40 PIN CONNECTIONS (5.08) 0.30 (7.62) (2.54) (10.16) (2.54) (16.3) (10.16) 0.10 (10.16) (7.62) (2.54) Pin Single Dual Triple 45 6 4 5 6 7 1 +Vin +Vin +Vin 0.10 2 -Vin -Vin -Vin (2.54) Dia. Dia. 1.0 Dia. 1.0 Dia. 1.0 0.20 Dia. 1.0 0.5 (0.04) (0.04) 0.04 (0.02) 3 Remote On/Off Remote On/Off Remote On/Off (5.08) (0.04) (0.04) (1.00) 4 +Vout +Vout +Vout 2 5 -Vout Com -Vout 3 1.80 Bottom View Bottom View 2.00 2.00 (45.72) 6 Trim -Vout Com (50.80) (50.80) Single & Dual Triple Output Models 7 +Vout 1 Output Models Dia. 0.20 Notes 0.04 (5.08) Dia. 1.0 Dia. 1.0 Dia. 1.0 Dia. 1.0 0.5 (1.00) 1. All dimensions are in inches (mm). (0.04) (0.04) (0.04) (0.04) (0.02) 2. Weight: 0.07 lbs (30 g) approx 12 3 1 23 3. Pin diameter: 0.04 0.002 (1.0 0.05) 0.20 0.30 0.20 4. Pin pitch tolerance: 0.014 (0.35) (5.08) (7.62) 0.10 Thermal Pad (5.08) (2.54) 0.20 5. Case tolerance: 0.02 (0.5) 0.10 (5.08) min (2.54) 0.60 (15.24) 0.50 (12.7) Application Notes Derating Curve Input Filter 100% +Vin +Vout + without heat-sink 12 H with heat-sink 75% DC/DC 100 F, LOAD Converter 100 V 50% 25% - -Vin Com 50 75 -40 -20 0 20 40 60 80 100 Ambient Temperature (C) 470 pF, 2Kv External Output Trim 6 6 Output can be externally trimmed using this method. R trim-up R trim-down Contact sales for details. 5 4 06-Aug-14 Output Power