xppower.com 150 500 Watts LCL Series Single Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs from 12 V to 48 V 3 Year Warranty Specification Input General Input Voltage 85-264 VAC (127-370 VDC) (see note 1) Efficiency 88% typical at full load & 230 VAC Isolation 3000 VAC Input to Output Input Frequency 47-63 Hz 1500 VAC Input to Ground Input Current 2.1 A max for LCL150, 4.5 A max for 500 VAC Output to Ground LCL300, 6.6 A max for LCL500 Switching Frequency 90-110 kHz main converter & 45-190 kHz Inrush Current 40 A max for LCL150, PFC for LCL150, 80-190 kHz main converter 60 A max for LCL300 & 500 & 62-65 kHz PFC for LCL300 & 500 cold start at 25 C, 230 VAC 3 3 Power Density 2.7 W/in LCL150, 4.4 W/in LCL300, Power Factor >0.9 3 4.9 W/in LCL500 Earth Leakage Current <2 mA at 264 VAC, 60 Hz MTBF LCL150: >489 kHrs, Input Protection LCL150: T3.15 A/250 V, LCL300: >235 kHrs, LCL300: T6.3A/250 V, LCL500: >211 kHrs to MIL-HBK-217F at LCL500: T10A/250 V, 25 C, GB internal fuse fitted in line Environmental Output Operating Temperature -10 C to +70 C, derate from 100% load Output Voltage See tables at 50 C to 50% load at 70 C Output Voltage Trim See tables Cooling LCL150 convection cooled, LCL300 & LCL500 have internal fans Initial Set Accuracy 100 mV at 50% load Operating Humidity 5% to 90% non condensing Minimum Load None required Storage Temperature -40 C to +85 C Start Up Delay 2 s max for LCL150, 1.5 s max for LCL300, 0.8 s max for LCL500 Operating Altitude 3000 m Start Up Rise Time 50 ms max for LCL150, Vibration 10-500 Hz, 2 g, 10 mins per cycle on 3 axes 35 ms max for LCL300 & LCL500 Hold Up Time 10 ms min at 115 VAC and full load EMC & Safety Line Regulation 0.5% max for LCL150, 0.3% for LCL300 & LCL500 Emissions EN55022 level B conducted, Load Regulation 1% max level A radiated Transient Response 4% max deviation recovery to within 1% Harmonic Currents EN61000-3-2 class A in 500 s for a 50% load change LCL150: EN61000-3-2 class C for loads 40% LCL300 & LCL500: EN61000-3-2 class C Ripple & Noise See tables for loads 20% Overvoltage Protection 110-140%, recycle input to reset Voltage Flicker EN61000-3-3 Overtemperature Output turns off when OTP triggered, ESD Immunity EN61000-4-2, 4 kV contact, Protection measured internally, auto recovery 8 kV air discharge, Performance Criteria A Overload Protection 110-150% of rated output power. Delayed Radiated Immunity EN61000-4-3, level 2 Perf Criteria A by 1 s min to allow for peak loads. EFT/Burst EN61000-4-4, level 2 Perf Criteria A Short Circuit Protection Trip and restart (hiccup mode), auto recovery Surge EN61000-4-5, installation class 3, Perf Criteria A Remote Sense Fitted to LCL500 only, compensates for 0.25 V max each line Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Remote On/Off Fitted on LCL500 only, Magnetic Field EN61000-4-8, 1 A/m Perf Criteria A On = logic low or open circuit, Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, Off = logic high 100% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1, UL60950-1, CSA60950 No 22.2 AC DCAC DC LCL150 Model and Ratings (1) (2) Output Power Output Voltage Trim Range Output Current Ripple & Noise Model Number 12.0 V 11.0-13.0 V 12.5 A 100 mV pk-pk LCL150PS12 13.5 V 12.5-14.5 V 11.1 A 100 mV pk-pk LCL150PS13 15.0 V 14.0-16.0 V 10.0 A 100 mV pk-pk LCL150PS15 150 W 24.0 V 23.0-25.0 V 6.3 A 150 mV pk-pk LCL150PS24 27.0 V 26.0-28.0 V 5.6 A 150 mV pk-pk LCL150PS27 48.0 V 47.0-49.0 V 3.1 A 250 mV pk-pk LCL150PS48 Notes 1. Output power derates linearly from 100% at 90 VAC to 90% at 85 VAC. 2. Measured with 20 MHz bandwidth. Mechanical Details 1.02 (26.0) 1.97 (50.0) 0.90 (23.0) 0.57 (14.5) 4.64 (118.0) 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration Terminal Block, M4 Screw 7 pins 0.37 (9.5) centre 2.44 (62.0) 2.83 (72.0) 1 3.74 (95.0) 2 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 7 J1 7.55 (192.0) 1.02 4.64 4 x M4 x 0.7 THD (26.0) (118.0) 0.15 (3.8) Max Screw Penetration 0.57 (14.5) 0.90 Pin Function (23.0) 1 +Vout 2 +Vout 3 -Vout 4 -Vout 5 Ground Notes 1. All dimensions shown in inches (mm). 3. Tolerance is 0.05 (0.2) maximum. 6 Neutral 2. Weight: 1.39 lbs (630 g) approx. 7 Line 100 100 80 90 60 40 20 30 40 50 60 70 -10 0 10 20 85 90 100 110 120 230 240 250 264 Input Voltage (VAC) Ambient Temperature (C) Output Power (%) Output Power (%)