LCW100 Series AC-DC POWER SUPPLIES CONVECTION 100W COOLED The LCW series of regulated output convection cooled AC-DC power supplies are designed to provide a cost eectivff e solution for industrial electronics, technology and household applications. Features include wide range AC input from 85-305VAC, output voltage adjustment, low stand-by power consumption, output short circuit protection, over current and over voltage protection. Applications include auxiliary power sources, security installations, lighting control, smart home or office control systems, ticketing and vending applications. Features 100W convection cooled Applications Integrated connector cover ITE, industrial & household approvals Class B conducted & radiated emissions Household Industrial Robotics Technology Appliances Electronics Input voltage range 85-305VAC Regulated single outputs from 5.0V to 48VDC Dimensions Output voltage trim 10% 5.079 x 3.819 x 1.181 (129.0 x 97.0 x 30.0mm) Efficiency to 90% Short circuit, overvoltage & overload protection Conformal coating option -30C to +70C operating temperature 3 year warranty Models & Ratings Output Voltage Ripple & Noise Maximum (3) (2) Model Number Output Current Efficiency Power (1) (4) pk to pk Capacitive Load Nominal Adjustment Range LCW100US05 5.0V 4.5 - 5.5V 18.0A 100mV 85% 10000F 90W LCW100US12 12.0V 10.8 - 13.2V 8.5A 120mV 87% 6800F 100W LCW100US15 15.0V 13.5 - 16.5V 7.0A 120mV 87% 3300F 100W LCW100US24 24.0V 21.6 - 26,4V 4.5A 150mV 89% 2200F 100W LCW100US36 36.0V 32.4 - 39.6V 2.8A 200mV 89% 1000F 100W LCW100US48 48.0V 43.2 - 52.8V 2.3A 200mV 90% 470F 100W Notes: 1. Ripple & noise measured with 20MHz bandwidth and 47F electrolytic capacitor in parallel with 0.1F ceramic capacitor. 2. Typical efficiencies measured at 230VAC full load. 3. Add suffix -E to model number to specify conformal coating option, MOQ applies, please contact sales. 4. Output power rating must not be exceeded.AC-DC POWER SUPPLIES LCW100 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions 85 115/230 305 VAC Derate output power linearly from 100% at 115VAC to 80% at 85VAC Input Voltage - Operating Alternative input. Not to be used in addition to AC input. DC input not 120 430 VDC included in safety approvals, external DC rated fuse required. Derate output power linearly from 100% at 163VDC to 80% at 120VDC Input Frequency 47 50/60 63 Hz 3.0 115VAC Input Current - Full Load A 1.5 230VAC No Load Input Power 0.5 W 35 115VAC cold start at 25C ambient Inrush Current A 65 230VAC cold start at 25C ambient Earth Leakage Current 0.75 mA 277VAC/50Hz (Typ) Input Protection T6.3A/300VAC Internal fuse fitted in line Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 4.5 52.8 VDC See Models & Ratings table 2 LCW100US05 Initial Set Accuracy % Full load 1 All other models Voltage Adjustment 10 % Minimum Load 0 A No minimum load required Start Up Delay 230 ms 115/230VAC full load 10 115VAC Hold Up Time ms 55 230VAC Drift 0.03 % After 20 minutes warm up, 230VAC, 0C to 50C Line Regulation 0.5 % 100-264VAC, full load 1.0 LCW100US05 0-100% Load Regulation % load 0.5 All other models Recovery within 1% in less than 5ms for a 50-75% and 75-50% load Transient Response 10 % step Ripple & Noise mV pk-pk See Models & Ratings table Over/Undershoot 10 % Full load 5ms recovery 7.5 LCW100US05 19.2 LCW100US12 24.0 LCW100US15 Overvoltage Protection VDC Hiccup mode, auto recovery 38.4 LCW100US24 57.6 LCW100US36 60.0 LCW100US48 Overload Protection 110 160 % Nominal output current, auto recovery Temperature Coefficient 0.03 5 %/C Short Circuit Protection Continuous, hiccup with auto recovery 2