120 180 Watts xppower.com SDS Series Convection cooled 3 x 5 Footprint Up to 90% Efficiency Open Frame, U Channel & Covered Versions Low Temperature Option Single & Multi Outputs 3 Year Warranty Specification Input General Input Voltage 90-264 VAC (120-370 VDC) Efficiency 120 W: 80% typical 150 W and 180 W: 88% typical Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output, 1500 VAC Input Current 120 W: 1.7 /1.0 A max at 115 /230 VAC Input to Ground, 500 VDC Output to 150 W: 2.0 /0.8 A max at 115 /230 VAC Ground 180 W: 2.7 A max at 90 VAC Isolation Resistance 50 M Inrush Current 120 W: 20 /51 A max at 115 /230 VAC 150 W: 54 /63 A max at 115 /230 VAC Switching Frequency 120 W: PFC 100 kHz typical, PWM 67 kHz 180 W: 54 /108 A max at 115 /230 VAC typical. 150 W: PFC 34 kHz minimum, PWM 55 kHz typical. 180 W: PFC 67 kHz Power Factor >0.9 typical, PWM 67 kHz typical Earth Leakage Current 120 W: 0.30 /0.75 mA at 115 /230 VAC 3 3 Power Density 120 W: 4.87 W/In , 150 W: 6.50 W/In 150 W: 0.40 /0.75 mA at 115 /230 VAC 3 180 W: 7.47 W/In 180 W: 0.75 mA at 230 VAC Signals Power Fail Detect = TTL active low, Input Protection Internal T3.15 A /250 VAC fuse in line combined AC and DC OK signal No Load Input Power 180 W: <0.5 W (-P versions SDS120 & 150 only) Warning time 16 ms Output MTBF >130 kHrs to MIL-HDBK-217F at 25 C, GB Output Voltage See table Environmental Output Voltage Trim 5% output 1 only (3.3 V variant 10%) SDS180: not user adjustable Operating Temperature 0 C to +70 C (-20 C to +70 C, SDS180), Initial Set Accuracy Single output models: 1% derate linearly from 100% load at +50 C Multi-output models: 5% to 50% load at +70 C, for low temperature option add suffix -L: Minimum Load No minimum load required for single -40 C to +70 C, SDS120 and SDS150, output models. For multi-output models not available for SDS180 (see table) Cooling Convection-cooled Start Up Delay 2 s max Operating Humidity 5-95% RH, non-condensing Start Up Rise Time 2 ms typical Storage Temperature -40 C to +85 C Hold Up Time 16 ms minimum at full load and 110 VAC Line Regulation 0.5% typical EMC & Safety Load Regulation 3.0% typical Emissions EN55022, level B conducted & radiated. Transient Response 4% max deviation, recovery to within 1% in 500 s for a 50% load change Harmonic Currents EN61000-3-2 class A Ripple & Noise 1% pk-pk typical, 20 MHz bandwidth Voltage Flicker EN61000-3-3 Overvoltage Protection 112-132% V1 only, recycle input to reset ESD Immunity EN61000-4-2, level 2 contact, Perf Criteria A SDS150: level 3 air, Perf criteria A Overload Protection All outputs: 110-150% with auto recovery (primary power limit) Radiated Immunity EN61000-4-3, level 2, Perf Criteria A Short Circuit Protection Trip & restart (hiccup mode), EFT/Burst EN61000-4-4, level 2, Perf Criteria A auto recovery Surge EN61000-4-5, installation class 3, Temperature 0.04%/C Perf Criteria A Coefficient Conducted Immunity EN61000-4-6, level 2 , Perf Criteria A Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, >95% 5000 ms Perf Criteria A, B, B Safety Approvals EN60950-1, UL60950-1,CSA60950-1 per cUL. AC DCAC DC SDS120 Models and Ratings Output 1 Output 2 Output 3 Output (2, 4, 5) Model Number (1) (1) (1) Power Vnom Imin Imax Tol. Vnom Imin Imax Tol. Vnom Imin Imax Tol. 72.0 W 3.3 V 0.00 A 22.00 A 5% SDS120PS03B 110.0 W 5.0 V 0.00 A 22.00 A 5% SDS120PS05B 115.0 W 7.0 V 0.00 A 16.42 A 5% SDS120PS07B 120.0 W 9.0 V 0.00 A 13.33 A 4% SDS120PS09B 120.0 W 12.0 V 0.00 A 10.00 A 3% SDS120PS12B 120.0 W 15.0 V 0.00 A 8.00 A 3% SDS120PS15B 120.0 W 18.0 V 0.00 A 6.66 A 3% SDS120PS18B 120.0 W 24.0 V 0.00 A 5.00 A 2% SDS120PS24B 120.0 W 28.0 V 0.00 A 4.28 A 2% SDS120PS28B 120.0 W 36.0 V 0.00 A 3.33 A 2% SDS120PS36B 120.0 W 48.0 V 0.00 A 2.50 A 2% SDS120PS48B 79.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.40 A 6.0 A 5% SDS120PD00B 120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.20 A 6.0 A 5% SDS120PD01B 120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.20 A 6.0 A 5% SDS120PD02B 120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.20 A 6.0 A 5% SDS120PD03B 120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.10 A 3.5 A 5% SDS120PD04B 120.0 W +5.0 V 1.50 A 15.00 A 5% -24.0 V 0.20 A 2.0 A 5% SDS120PD05B 120.0 W +28.0 V 0.39 A 3.92 A 5% +5.0 V 0.20 A 2.0 A 5% SDS120PD06B 91.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 1.0 A 5% SDS120PT00B 91.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 1.0 A 5% SDS120PT01B 120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +5.0 V 0.00 A 0.8 A 5% SDS120PT02B 120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -5.0 V 0.00 A 0.8 A 5% SDS120PT03B 120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT04B 120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT05B 120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +5.0 V 0.00 A 0.8 A 5% SDS120PT06B 120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -5.0 V 0.00 A 0.8 A 5% SDS120PT07B 120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT08B 120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT09B 120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.60 A 6.0 A 5% -15.0 V 0.00 A 0.8 A 5% SDS120PT10B 120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.60 A 6.0 A 5% +15.0 V 0.00 A 0.8 A 5% SDS120PT11B 120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% -24.0 V 0.00 A 0.8 A 5% SDS120PT12B 120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% +24.0 V 0.00 A 0.8 A 5% SDS120PT13B 120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT14B 120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT15B 120.0 W +5.0 V 1.50 A 15.00 A 5% +10.0 V 0.60 A 6.0 A 5% -10.0 V 0.00 A 1.0 A 5% SDS120PT16B 120.0 W +5.0 V 1.50 A 15.00 A 5% +10.0 V 0.60 A 6.0 A 5% +10.0 V 0.00 A 1.0 A 5% SDS120PT17B Notes 1. Tol. (total regulation) includes line regulation and load regulation. 4. For optional low temperature -40 C operation, add suffix -L to model 2. For optional PCB only version, delete suffix B from model number. number. Example: SDS120PS12B-L Example SDS120PS03. 5. For optional Power Fail Detect circuit, add suffix -P to model number, 3. For non-standard voltages contact sales. example: SDS120PS12B-P Mechanical Details PIN CONNECTIONS 1.18 (30.0) Pin Single Dual Triple Power Fail Detect (PFD) 1 V1 V2 V2 is +5 V for normal operation. +5 V 2 V1 V2 V2 0.25 (6.4) Source current is 5 mA max. 3 V1 V1 V1 4.49 (114.3) 4 V1 V1 V1 0.10 (2.5) 0.32 (8.1) PFD is <0.4 V for either Pin 13 1.54 (39.2) M3XP0.5 (Mounting Holes) X 4 5 V1 V1 V1 AC Fail (<90 VAC) or 6 V1 V1 V1 DC Fail (<95% Vnom). 7 Return Common Common Sink current is 10 mA max. P2 8 Return Common Common 1 V Adj. 9 Return Common Common 10 Return N/C V3 3.20 DCDC 2.57 AC OUTPUTOUTPUT P1 (81.4) (65.3) 11 Return Common Common INPUT L 12 Return Common Common Internal N (1) (1) (1) 13 PFD PFD PFD GG Notes 2.70 (68.6) 0.55 (14.0) 1. Optional Power Fail Detect signal on -P versions only. Standard models pin 13 is N/C. 2. I/P connector P1 mates with Molex housing 09-50-3051 & Molex 2878 series crimp terminal. 5.00 (127.0) 3. O/P P2 mates with Molex housing 09-50-3131 & Molex 2878 series crimp terminal. 4. For optional cover kit order part number SDS120 COVER, to receive unit with cover fitted M3xP0.5 (Mounting Holes) X 3 4.49 (114.3) add suffix -C to model number, e.g. SDS120PS12B-C (overall height is 1.73 (44.0)). 4.00 (101.6) 5. For mating connector kit order part number SDS120/SDS150 CON KIT. 0.25 (6.4) 6. For cable harness order part number SDS120S LOOM for single output models & SDS120M LOOM for multi-output models. 7. Maximum mounting screw penetration: 0.14 (3.5) 8. All dimensions are in inches (mm). 9. Weight: 0.77-0.99 lbs (350-450 g) approx. 10. For PCB-only version, overall dimensions are max 5.00 x 3.00 x 1.44 (127.0 x 76.2 x 36.6). 3.20+0.20 0.01 (81.4 +0.5 -0.2) 3.01+0.20 0.00 (76.4 +0.5 0.0) 1.18 (30.0)