90 Watts xppower.com VEH Series Energy Efficiency Level V CEC 2008 & EISA 2007 Compliant High Power Density Single Outputs from 12 V to 24 V No Load Input Power <0.5 W Optional Output Connector Low Cost BRAND Specification Input G eneral Input Voltage 90-264 VAC Efficiency See table Input Frequency 47-63 Hz Energy Efficiency Level V Input Current 1.5 A max at 90 VAC Isolation 3000 VAC Input to Output, 1500 VAC Input to Ground Inrush Current 110 A max at 230 VAC, cold start at 25 C PS12: 500 VDC Output to Ground, Earth Leakage Current <1 mA at 230 VAC/50 Hz PS19/24: Negative output is connected to Power Factor >0.95 at 230 VAC and full load Ground No Load Input Power <0.5 W Switching Frequency PFC: 25-125 kHz, PWM: 60 kHz typical Input Protection Internal T2.0A/250 V fuse in line MTBF >160 kHrs to Bell Core iss. 6 Environmental Output Operating Temperature 0 C to +60 C derate linearly from 100% Output Voltage See table load at +40 C to 50% load at +60 C, Initial Set Accuracy 5% at 50% load Storage Temperature -10 C to +85 C Minimum Load No minimum load requirement Operating Humidity 5% to 90% RH non-condensing Hold Up Time 10 ms min at 115 VAC, full load Storage Humidity 5% to 95% RH non-condensing Start Up Delay 3 s max Shock 6 Random drops from 0.7 m with no Start Up Rise Time 8 ms typical damage, 50 g for 20 ms in each of 3 axes Transient Response 4% maxiumum deviation, recovering to Vibration 2 g variable frequency from 20 Hz to 30 Hz less than 1% within 500 s for a 50% step load change Line Regulation 0.5% max EMC & Safety Load Regulation 5% max Emissions EN55022, level B conducted & radiated Ripple & Noise 1% pk-pk max, 20 MHz bandwidth (see note 1) Harmonic Currents EN61000-3-2 class A, EN61000-3-2 class C >60% load Overvoltage Protection See table Voltage Flicker EN61000-3-3 Overload Protection 120 -180% ESD Immunity EN61000-4-2, level 3 Perf Criteria A Short Circuit Protection Continuous (hiccup/trip & restart mode with auto recovery) Radiated Immunity EN61000-4-3, 3 V/m Perf Criteria A Temperature 0.04%/C EFT/Burst EN61000-4-4, level 3 Perf Criteria A Coefficient Surge EN61000-4-5, installation class 3, Perf Criteria A Conducted Immunity EN61000-4-6, level 2 Perf Criteria A Magnetic Field EN61000-4-8, 3 A/m Perf Criteria A Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals EN60950-1:2001, UL/cUL60950-1 AC-DCAC-DC VEH90 Models and Ratings (2) (3) (4) Output Power Output Voltage Output Current OVP Setting Effeciency Model Number 90 W 12.0 V 7.50 A 16.0 V 88% VEH90PS12 90 W 19.0 V 4.74 A 25.0 V 88% VEH90PS19 90 W 24.0 V 3.75 A 32.0 V 89% VEH90PS24 Notes 1. Measured at the output connector with a 0.1 F ceramic capacitor and a 10 F 3. Average of efficiencies measured at 25%, 50%, 75% and 100% load and electrolytic capacitor. 230 VAC input. 2. Typical values. 4. For optional barrel jack connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix -B e.g. VEH90PS24-B Mechanical Details 1 3 2 4 Pin Function 1 Output + 2 Output + 3 Return* 4 Return* Shell Floating *Return is internally connected 5.24 to input earth on 19 V & 24 V (133.0) models Power Cord, Order Part: UK - UK-MAINS-5 European - EU-MAINS-5 US - US-MAINS-5 1.19 2.28 (30.3) (58.0) IEC320-C6 0.67 (17.0) Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight 0.82 lbs (370 g) approx. 3. Cable length is 482(1220 50 mm) approx. 4. Output connector (Power Mini Din) mates with Kycon KPJX-4S or equivalent. 15 Jan 18