AC-DC Power Supplies XPPower VES90 Series 90 Watts Energy Efficiency Level VI European CoC Tier 2 High Power Density Single Outputs from 12 V to 48 V <0.15 W Standby Power China Compulsory Certification (CCC) Qualified 0 C to 60 C Operation BRAND Optional Output Connector Low Cost Dimensions: VES90: 5.47 x 2.28 x 1.22 (139.0 x 58.0 x 31.0 mm) Models & Ratings (1) (2) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number 12.0 V 7.50 A 89% VES90PS12 19.0 V 4.74 A 89% VES90PS19 90 W 5% 24.0 V 3.75 A 89% VES90PS24 48.0 V 1.875 A 89% VES90PS48 Notes 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For optional Barrel Jack Connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix -B e.g. VES90PS24-B. Mechanical Details 47.24 0.79 (1200 20) 5.47 (139.0) Pin Function 1 Output + 2 Output + 2.28 3 1 3 Return (58.0) 4 Return Connected to output 2 4 Shell return and input ground LED Indicator 1.22 IEC320-C14 (31.0) Rating Label Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except 3. Weight: 0.82 lbs (370 g) approx. output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent. www.xppower.com 1AC-DC Power Supplies XPPower VES90 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 1.5/0.6 A Measured at 115/230 VAC Inrush Current 130 A 230 VAC, cold start at 25 C Power Factor EN61000-3-2 Class A Earth Leakage Current 3.5 mA 264 VAC, 60 Hz No Load Input Power 0.15 W Input Protection T3.15A/250 VAC internal fuse in line Output Characteristic Min. Typ. Max. Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 2 % At 50% load Minimum Load No minimum load required Start Up Delay 3 s Start Up Rise Time 50 ms Hold Up Time 8/16 ms Full load and 115 VAC/230 VAC Line Regulation 0.5 % Total Regulation 5 % Maximum deviation, recovering to less than 1% within Transient Response 4 % 500 s for 25% step load change 2% for 12/19/24 V, 1% for 48 V, Ripple and Noise 2/1 % pk-pk 20 MHz bandwidth, measured with 20 MHz Bandwidth and 10 F electrolytic in parallel with 0.1 F ceramic capacitor. Overshoot 5 % At turn on / turn off Overload Protection 120 200 % Overvoltage Protection 180 % Recycle mains to reset Short Circuit Protection Trip and restart (hiccup), auto resetting Temperature Coefficient 0.04 %/C Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 50% load at 60 C Cooling Natural convection Operating Humidity 10 90 %RH Non-condensing Storage Temperature -40 +70 C Operating Altitude 5000 m Shock IEC68-2-27, 30 g, 30 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-500 Hz, 0.25 g 10 mins/sweep, 60 mins for each of 3 axes 100% Derating Curve 80% 60% 40% 20% 0 20 40 60 Ambient Temperature (C) www.xppower.com 2 Output Power (%)