AC-DC Power Supplies VEU10 Series 10 Watt USB Power Adapter xxx Series Energy Efficiency Level VI European CoC Tier 2 Fixed Mains Connectors Universal Input Output Voltage 5.0 V Class II Construction BRAND Low Cost Dimensions: The VEU10 series of wall plug USB adaptors comply with the very latest energy efficiency VI VEU (Case Only): standards with high active mode efficiency and extremely low no load power consumption. -US: 1.45 x 0.86 x 2.0 (37.0 x 22.0 x 50.8 mm) -EU: 1.45 x 0.86 x 2.2 (37.0 x 22.0 x 56.5 mm) -UK: 1.92 x 1.68 x 2.0 (48.8 x 42.8 x 50.8 mm) Models & Ratings (2) Output Power Output Voltage Output Current Total Regulation Input Connector Model Number 5.0 V 2100 mA 5% UK VEU10US050-UK 10 W 5.0 V 2100 mA 5% US VEU10US050-US 5.0 V 2100 mA 5% EU VEU10US050-EU Notes 1. Total regulation includes initial set accuracy, line and load regulation. 2. For white case version add suffix -W e.g. VEU10US050-US-W. MOQ applies, contact sales for details. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 0.3 A 100 VAC Inrush Current 60 A 240 VAC, cold start at 25 C Power Factor EN61000-3-2, class A No Load Input Power <0.075 W Input Protection Internal T1.0A/250 VAC fuse Output Characteristic Minimum Typical Maximum Units Notes & Conditions Minimum Load 0 A No minimum load required Start Up Delay 4 s Start Up Rise Time 30 ms Hold Up Time 11 ms Full load and 115 VAC Total Regulation 5 % See Models and Ratings table Recovely within <1% within 500 s for a 50% step load Transient Response 4 % deviation change at 0.15 A/s Measured with 20 MHz bandwidth and 47 F electrolytic in Ripple & Noise 200 mV pk-pk parallel with 0.1 F ceramic capacitor Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovely Temperature Coefficient 0.05 %/ C www.xppower.com 1AC-DC Power Supplies VEU10 Series General Characteristic Minimum Typical Maximum Units Notes & Conditions Energy Efficiency Level VI and CoC Tier 2 Isolation 3000 VAC Input to Output Switching Frequency 24 70 kHz Variable Mean Time Between Failure 100 kHrs MIL-HDBK-217F at 25 C GB Weight 0.11 (50) lb (g) For -UK version Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 50% load at 60 C Storage Temperature -40 +85 C Operating Humidity 5 95 % RH, non-condensing Cooling Natural convection Shock 1 m drop onto concrete on each of 6 axes Vibration 10 300 Hz 2 g 15 mins/sweep, 60 mins for each of 3 axes EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55032 Level B Radiated EN55032 Level B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 EMC: Immunity Phenomenon Standard Test Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 2,3 A 4 kV contact, 8 kV air Radiated Immunity EN61000-4-3 3 V/m A EFT/Burst EN61000-4-4 Level 2 A Surge EN61000-4-5 Level 2 A Conducted Immunity EN61000-4-6 3 V A Magnetic Fields EN61000-4-8 1 A/m A Dips and Interruptions EN55024 100% 10 ms, 30% 500 ms, 100% 5000 ms, Perf Criteria A, A, B Safety Approvals Phenomenon Standard CB Report IEC60950-1, IEC62638-1 UL UL62368-1 TUV EN60950-1, EN62368-1 CCC China Compulsory Certification, GB4943 AU/NZ AU/NZ 60950.1 www.xppower.com 2