RZB-05 WIRELESS CONTROL SET CONNECTION ROP-01 MOUNTING - UNIVERSAL MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special meas- ZAMEL Sp. z o.o. ure equipment. 3. Connect the cables with the terminals in accordance with the installing diagram. ul. Zielona 27, 43-200 Pszczyna, Poland 4. Install ROP-01 device in installation ca- tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl ble box. 5. Switch on the power supply from the mains. DESCRIPTION TECHNICAL DATA Radio flush receivers are used both as P-257/2 ROP-01 elements in mounting in flush and surface Input (supply) terminals: - L, N Input rated voltage: 3 V DC (CR2032 battery) 230 V AC installation cable boxes and as an actuator CAPACITY P-257/2 OPERATION Battery life: 3 5 years - built directly in lighting fitting casings and By pressing the P-257/2 push-button, Input voltage tolerance: - -15 +10 % other receivers). ROP-01 enables op- 750W 500W the remote controller sends a signa l with Nominal frequency: - 50 / 60 Hz eration in 5 different modes (switching on, 868,32 MHz frequency which controls Nominal power consumption: - 0,29 W 250W 375W switching off, monostable mode, bistable EXTA FREE receivers. Device program- Number of operation modes: - 5 mode, time mode. ming procedure (adding a transmitter Number of channels 2 1 to a receivers memory) is described in Transmission: radio 868,32 MHz APPLICATION particular EXTA FREE manual instruc- FEATURES Coding way: unidirectional tions. The device range (up to 250 m de- Coding: addressing transmission pending on a receiver) can be increased complete set of wireless control (2chan- Maximum number of remote controls: - 32 by means of a retransmitter or few RTN-01 nel remote controller P-257/2 and 1-chan- Range: up to 180 m in the open area up to 180 m in the open area nel radio flush receiver ROP-01), retransmitters. Time adjustment: - 1 sec 18 hours (every 1 sec) lighting, heating operation control, other receivers control, Optic signalling of transmitters operation: LED red diode BATTERY CHANGE P-257/2 easy installation in an electric-light fitting Relay output terminals: - 12, 11, 14 or in 60 mm junction box, Relay contact parameters: - 1NO/NC 5A / 250V AC AC1 1250 VA Battery discharge status is signalled possibility to use the second remote con- Number of terminal clamps: - 5 by several LED red diode flashes dur- troller s push-button to control other EXTA 2 Section of connecting cables: - up to 2,5 mm ing transmission time. FREE receivers, o 5 operation modes: switching on, switch- Ambient temperature range: -10 +55 C 1. Remove the button (mounting - point 1). ing off, monostable mode, bistable mode, Operating position: free 2. By means of a screwdriver lever up the time mode (switch off delay), Mounting: - installation cable box 60 mm printed-circuit board releasing the bot- wide operation range (up to 180 m), Casing protection degree: IP20 (EN 60529) tom latch and remove it from the base. low current consumption, possibility of Protection level: III II 3. Remove the battery from the latch. constant operation, possibility of increasing operation range Overvoltage category: - II 4. Mount a new battery. Watch battery by means of RTN-01 retransmitter. polarisation marked on the latch. Pollution degree: 2 Wrong battery mounting may cause Surge voltage: - 1 kV (PEN 61000-4-5) device damage. Dimensions: 74 x 33 x 11,5 mm 47,5 x 47,5 x 20 mm 5. Put the removed printed-circuit board Weight 0,020 kg 0,043 kg back in the base. Reference standard: ETSI EN 300 220-1 EN 60669, EN 60950 T h e dev i c e i s de si gne d f o r ETSI EN 300 220-2 EN 61000 6. Put back the button. s in g l e - p ha s e in st allat i o n an d must be installed in accord- 2-channel remote controller P-257/2 anc e w it h st an da r d s val i d in CAUTION: operates radio flush receiver APPEARANCE a par t i c ular c o unt r y. T h e de- While changing the battery, it is sug- ROP-01 and remote control socket v i c e sh o uld be c onn ec ted CAUTION RWG-01. RNK-02 button radio gested to press any of the buttons for ac c o r din g to t h e det ails in- Relay output terminals c l u d e d in t h i s o p e r at in g m an ual. I n st a llat i o n, transmitter and RWL-01 radio about 5 seconds before putting it into (12, 11, 14) c onn ec t i on an d c ont r o l sh o uld be c a r r ied o ut by lighting switch are also EXTA FREE The ZAMEL company a latch. Next press transmission button a quali fi e d e l e c t r i c ian st af f, w h o ac t in ac c o r d- devices which are system devices. several times to check its operation. anc e w it h t h e s e r v i c e m anual an d t h e dev i c e characterised with this sign Input (supply) terminals (L, N) If the transmitter does not work proper- functions. can cooperate In c ase of c asing dismant ling an elec t ric sho c k with each other. ly repeat the battery change procedure. m ay o c c ur, an d t h e guar ante e i s l o st t h e n. B e- fore installation make sure the c onnection c a- Optic signalling b l e s are n ot un de r vo lt ag e. T h e c r uc i fo r m h e ad WARRANTY CARD of receiver s operation screwdriver 3,5 mm should be used to instal the dev i c e. Imp r o p e r t r ansp o r t , sto r ag e, an d us e Programming push-button There is 24 months guarantee on the product of t h e dev i c e in fl u e nc e it s w r o n g f unc t i o nin g. 1. ZAMEL provides a two-year warranty for its products. It i s n ot adv i s ab l e to inst al t h e dev i c e in t h e 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances following cases: if any device part is missing b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- Push-buttons o r t h e dev i c e i s dam ag e d o r defo r m e d. In c as e TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting of improper functioning of the device contact Optic signalling of transmitters operation from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device t h e p r o duc e r. in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. The symbol means selective 4. ZAMEL will review complaints in accordance with existing regulations. collecting of electrical and electronic 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. between the goods and the contract. It is forbidden to put the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 003 20.05.2011ROP-01 OPERATION TIME PROGRAMMING ROP-01 can operate in five modes: 1s 2s ns MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ter s push-button. status cyclically always -button. adjusted time (tp), after pressing the same push- SWITCH OFF but it may be switched off before -button. the device switches off adjusted time finishes. Default Press PROG push-button of ROP-01 device for a longer time till Press PROG push-button of ROP-01 device After the adjusted time is after pressing the push- settings - 15 seconds. LED red diode switches on (constant signal). Next release PROG and then release it. LED red diode switches finished (the number -button. push-button. Wait (for about 5 seconds) till LED red diode switches off and then switches on (signal pulsates). of LED red diode flashes) CAUTION Adjusted time can on (first signal pulsates, next the signal is constant). Every LED diode pulse equals 1 second. press PROG push-button not be deleted. and then release it - TIME IS ADDED. Maximum time is 18 hours. RADIO TRANSMITTERS DELETION RADIO TRANSMITTERS PROGRAMMING Press PROG push-button of ROP-01 After 5 seconds LED red diode switches on Release the push-button in ROP-01 - device for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED. MONOSTABLE mode: COOPERATION AND OPERATING RANGE Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press transmitters Press PROG push-button of ROP-01 device Release transmitter s push- RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press the same transmitter s push- push-button for for a longer time until LED red diode button. LED red diode switches -button and release it. LED red P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m a longer time. switches on (constant signal). on (first signal pulsates, diode switches on (the signal pulsa- P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Next release PROG push-button. next the signal is constant). tes) and next it switches off - THE RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m TRANSMITTER IS ADDED. BISTABLE mode: RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of ROP-01 device Press the transmitter s push-button Release transmitter s push-button. * - 1-channel transmitters do not cooperate with roller blind controllers. for a longer time until LED red diode for a longer time. LED red diode LED red diode switches on (the CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, switches on (constant signal). switches on (first signal pulsates, signal pulsates), next the LED red it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, Next release PROG push-button. next the signal is constant). glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have diode switches off - it means the also a negative influence on the range. TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): TRANSMITTERS RECEIVERS RNK-02 RNL-01 ROP-01 RWL-01 2channel button Radio 1-channel Radio lighting radio transmitter foot transmitter radio receiver switch RNK-04 RTI-01 ROP-02 RWG-01 4-channel button IR/EXTA FREE 2-channel Remote control Press PROG push-button of ROP-01 device Press and release transmitters Press and release the same transmitter s radio transmitter transceiver radio receiver socket for a longer time until LED red diode push-button. LED red diode push-button. LED red diode switches on switches on (constant signal). switches on (first signal pulsates, next (the signal pulsates) and next it switches P-256/8 RNM-10 RDP-01 SRP-02 Next release PROG push-button. the signal is constant). off - THE TRANSMITTER IS ADDED. 8-channel 4-channel radio 1-channel Radio roller blinds remote controller modular transmitter radio dimmer controller TIME mode (one push-button): P-257/4 RNP-01 ROB-01/12-24V SRP-03 4-channel 4-channel Radio Central radio roller remote controller radio transmitter gate controller blinds controller P-257/2 RNP-02 ROM-01 ROM-10 2-channel 4-channel 1-channel radio 2-channel remote controller radio transmitter modular receiver radio modular receiver Press PROG push-button of ROP-01 device Press transmitter s push-button and then Press and release the same transmitter s RCR-01 RXM-01 for a longer time till LED red diode release it. LED red diode switches on push-button. LED red diode switches on Radio Translator switches on (constant signal). (first signal pulsates, next (signal pulsates) and then switches off - motion sensor RS-485/EXTA FREE Next release PROG push-button. the signal is constant). THE TRANSMITTER IS ADDED. ACCESSORIES An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters ANT-01 RTN-01 is analogous. CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to External antenna Retransmitter the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. VER. 003 20.05.2011