GENERAL PURPOSE SINGLE & DOUBLE POLE ESeries Features Thermoplastic actuating button Stainless steel springs 5 current ratings Phenolic case Choice of actuator styles NC terminal 3 terminal types (optional screw Common terminals available consult factory) terminals NO terminal NC terminal 3 contact arrangements Long-life coil spring mechanism NO terminal High-temperature 150C and 200C Brass moving blades Silver alloy, silver-cadmium oxide or available on select models (consult factory) gold crosspoint contacts Electrical Ratings Electrical Life at Rated Load Switch According to VDE According to UL Series EN61058 Rating UL1054 Rating (Min. Operations) (Min. Operations) E13/E19 N/A 15A, 125/250VAC 3/4HP, 125VAC N/A 6,000* 1-1/2HP, 250VAC E19A N/A 15A, 125/250VAC 0.1A, 125VAC N/A 6,000 (mixed ratings) E14/E25 N/A 25A, 125/250VAC 1HP, 125VAC N/A 6,000 2HP, 250VAC E20 N/A 20A, 125/250VAC 1HP, 125VAC N/A 6,000 2HP, 250VAC E28/E29 N/A 30.1A, 125/250/277VAC N/A 6,000 (UL Approved Only Resistive Load Only) E30 N/A 30.1A, 125/250VAC 1HP, 125VAC N/A 6,000 2HP, 250VAC G13/G20 N/A 0.1A, 125VAC N/A 6,000* *Indicates 100K life available. Specifications Electrical Temperature Rating: 105C Std. (150C and 200C optional E13, E14, E19, E20, G13) 85C Std. (E28 and E29), 85C Std. (150C optional) E25 Flammability Rating: UL94HB Materials Case: General Purpose Phenolic Actuating Button: Thermoplastic Nylon Common Terminals: Brass (E13, E19, E19A, G13, G20) Silver-Plated Brass (E14, E20, E28, E29, E30) NO and NC Terminals: Brass (E13, E19, E19A, G13, G20) Copper (E14, E20, E28, E29, E30) Moving Blade: Brass (E13, E19, E19A, G13, G20) Silver-Plated Beryllium Copper (E14, E20, E28, E29, E30) Spring: Stainless Steel Auxiliary Actuators: Cold-Rolled Steel (Nickel-Plated) Roller: Sintered Stainless Steel Contacts: Gold Crosspoint (G13, G20, E19A) Silver-Cadmium Oxide (E13, E14, E19, E20, E28) Silver Alloy (E19A, E29, E30) (E25 only)Dimensions Single Pole inches (mm) Actuators Single Pole Standard type integral hinged lever and roller actuators are available in choice of Cavity for External two mounting positions. Actuation lengths Auxiliary Actuator + 0.310 0.005 - are dimensioned from centerline of switch + (7.92 0.13) - 0.250 (6.35) x 0.032 (0.813) mounting hole as shown. Q.C. or Faston Terminal + 0.640 0.015 - + (16.26 0.38) - Actuation 0.375 (9.53) Length 0.375 (9.53) 0.250 (6.35) diameter 0.095 (2.41) Dia. Hole (3 places) 0.135 +0.005 +0.005 0.145 (3.68) Diameter x 0.175 -0.010 0.150 0.010 Switch Mounting Hole 0.130 Reference High Ratio Standard Ratio 0.500 (12.7) (3.30) 0.195 Line (4.95) Actuation 0.375 (9.53) Length + 0.300 + 0.380 0.015 0.640 0.015 - - N.C. (7.62) + + (16.26 0.38) (9.65 0.38) - 0.250 (6.35) - COM N.O. 30 Switch + 0.33 0.41 1.000 0.007 - Mounting Hole + (8.38) (25.4 0.18) (10.41) - High Ratio Standard Ratio + + 1.823 0.015 0.364 0.015 0.41 - - + + (10.41) (46.30 0.38) (9.25 0.38) - - J & M Type Optional Hardware Single Pole Actuator Specifications Single Pole Brass Hex Nut 0012-0023 MaximumMaximum Operating MinimumMax. MovementActuation Operating Pre-Travel Point* Over-Travel Differential Length** Brass Knurled Nut 0012-0025 Series/ Actuator Switch Force inches inches inches inches inches Prefix Type Type (g) (mm) (mm) (mm) (mm) (mm) Brass Hex Nut 0012-0028 (Nickel-Plated) E13/G13 00E 425 0.050 0.2850.020 0.100 0.015 (1.27) (7.240.51) (2.54) (0.38) Brass Knurled Nut 0012-0021 E14/E29/E30 00A 850 0.100 0.2480.026 0.050 0.015 (Nickel-Plated) (2.54) (6.300.66) (1.27) (0.38) Star Washer 0012-0073 E13/G13 00J 425 0.050 0.6700.030 0.108 0.015 (1.27) (17.020.76) (2.74) (0.38) Extra Over-travel with Internal E14/E29/E30 850 0.100 0.6330.030 0.050 0.015 Thermoplastic Spring-loaded Metal Button Button (2.54) (16.080.76) (1.27) (0.38) - OOM Suffix - OOJ Suffix E13/G13 00M 425 0.050 0.8120.030 0.218 0.015 3/8 x 32 Thread (1.27) (20.630.76) (5.54) (0.38) 0.406 (10.31) 0.312 (7.93) Flat Both Sides E14/E29/E30 850 0.100 0.7750.030 0.168 0.015 (2.54) (19.690.76) (4.27) (0.38) E13/G13 00H 100 0.250 0.3120.062 0.187 0.093 1.500 (6.35) (7.931.57) (4.75) (2.36) (38.10) Circuitry Single Pole E14/E29/E30 285 0.312 0.4680.062 0.150 0.050 0.821 Contact arrangement available in choice of (7.93) (11.891.57) (3.81) (1.27) (20.85) single pole double throw or single pole sin- E13/G13 50H 65 0.343 0.2810.062 0.187 0.140 1.750 gle throw, either normally open or normally (8.71) (7.141.57) (4.75) (3.56) (44.45) closed. In general, normally open may be E14/E29/E30 170 0.525 0.4370.062 0.218 0.080 1.071 specified by changing suffix number from (13.34) (11.101.57) (5.54) (2.03) (27.20) 00 to 01 and normally closed by changing E13/G13 00K 100 0.250 0.7180.062 0.187 0.093 1.391 suffix number to 02. (6.35) (18.241.57) (4.75) (2.36) (35.33) Example: E13-00E is double throw, E14/E29/E30 285 0.348 0.8600.062 0.130 0.045 0.652 (8.84) (21.841.57) (3.30) (1.14) (16.56) E13-01E is normally open, and E13-02E is normally closed. E13/G13 50K 65 0.343 0.6870.062 0.187 0.140 1.645 (8.71) (17.451.57) (4.75) (3.56) (41.78) E14/E29/E30 170 0.483 0.8280.062 0.218 0.073 0.902 Terminals Single Pole (12.27) (21.031.57) (5.54) (1.85) (22.91) Standard 0.250 x 0.032 (6.35mm x 0.81mm) * Measured above reference line. Refer to dimensional drawing above. **Actuator tolerance 0.031 inches (0.79mm). E14, E29 and E30 actuators are shorter and formed up 11 at the button. Optional 0.187 x 0.032 (4.75mm x 0.81mm) QC terminals can be furnished with angle Ordering Information Mounting Single Pole formed up or down. Forms include straight 30, 45, 85 up or down. Other forms can Recommended mounting screw: 6-32 Select the current rating you need. be provided. Screw terminal UL approved round head. Recommended torque on Combine the corresponding Series/Prefix on E14 and E30 only. screw: 6 inch lbs. max. number with the appropriate suffix number for the switch you need. Specifications subject to change without notice. 49