Scotchlok Terminals W C MV18-4FB/S thru MV10-10FB L E Block Fork, Vinyl Insulated, Brazed Seam Data Sheet Wire Maximum Product Range Stud Barrel Barrel Insulation Number (AWG)SWize C L E Thickness Length I.D. Diameter M8V18-4FB/S242-1 05.2505.200.800.705.03 00.205.07 0.14 M8V18-6FB/S262-1 05.2505.200.800.705.03 00.205.07 0.14 M8V18-6FB262-1 05.3005.200.800.705.03 00.205.07 0.14 M8V18-8FB282-1 05.3005.200.800.705.03 00.205.07 0.14 M8V18-10FB202-1 1005.305.200.800.705.03 00.205.07 0.14 M4V14-4FB/S146-1 05.2505.200.800.705.03 00.200.09 0.17 M4V14-6FB/S166-1 05.2505.200.800.705.03 00.200.09 0.17 M4V14-6FB166-1 05.3005.200.800.705.03 00.200.09 0.17 M4V14-8FB186-1 05.3005.200.800.705.03 00.200.09 0.17 M4V14-10FB106-1 1005.305.200.800.705.03 00.200.09 0.17 M0V10-6FB162-1 09.3203.214.000.805.04 05.200.13 0.25 M0V10-8FB182-1 09.3203.214.000.805.04 05.200.13 0.25 M0V10-10FB102-1 1209.303.214.000.805.04 05.200.13 0.25 Installation Information UL Listed and CSA Certified for use on stranded copper (AWG) wire only. CANADIAN STANDARDS LISTED 314R Strip away the end 3/8 inch of wire insulation. ASSOCIATION UNDERWRITERS STANDARD NO. C22.2 LABORATORIES Make the crimp in the proper station of a recommended NO. 0. 65 STANDARD NO. UL 486A 3M crimp tool: TH-440, TH-450 (scissor style), or TR-490 3M FILE NO. LR22190 3M FILE NO. E23438 (ratchet style) hand tools. Specifications Barrel Crimp (Electrical) Wire Size: See Table Above Barrel Seam: Brazed Max. Voltage Rating: 600 V Building Wire 1000 V Signs, Fixtures Suitable for factory application on steel or brass tabs UL or and Luminaires CSA. Max. Temperature Rating: 221F (105C) Suitable for field application on brass tabs, strain relief Max. Current: Same as Wire required, UL only. Insulator Material: Vinyl Terminal Material: ETP Copper Plating: TinEngineering Specification The vinyl-insulated, brazed seam block fork terminal shall Crimp-type terminals shall, electrically and mechanically, be tin-plated, annealed copper, with the tongue having a connect to a pre-stripped end of a stranded copper wire: specified stud slot (size 4 thru 10) and a brazed seam and have a flat tongue portion with a central opening for barrel covered by a molded vinyl funnel entry sleeve, color mounting around a screw or stud. coded and sized, for a specified (AWG) wire range (22-18, 16-14, 12-10). The terminal line shall offer tongue variations in hole (stud) size (6, 8 10, etc.) and configuration (ring, fork, Insulated terminals shall be UL Listed and CSA Certified block fork, flanged block fork, locking fork, etc.): and for 600 Volts maximum building wire: 1000 Volts barrel variations in wire (AWG) size (22-18, 16-14, 12-10, maximum in signs, fixtures and luminaries and have a etc.) and construction (non-insulated brazed seam, vinyl maximum operating temperature of 221F (105C). insulated butted seam, nylon insulated with insulation grip, etc.). The terminal line shall have regulatory agency coverage (UL Listing, CSA Certification). The terminal tongue shall be marked with the wire range and manufacturers symbol ( ). 3M and Scotchlok are trademarks of 3M IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty Limited Remedy Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3Ms option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Litho in USA.