Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M Features The miniature circuit breakers of the Clear contact position indication in red/green (real CPI) System pro M compact series S 200 Unique, patented twin terminal with captive screws and 2 and S 200 M provide state-of-the-art an increased opening for cables up to max. 35 mm , finger-proof (IP20) safety and comfort. They stand out due Busbar slot in the back for best visibility during installation to their high performance and the wide High performance at an increased rated voltage for marine range of accessories and approvals. and industrial applications: 10 kA/15 kA at U = 440 V AC e acc. to IEC/EN 60947-2 Individual product identification code Approved acc. to IEC/EN 60898-1, IEC/EN 60947-2 and UL 1077/CSA 22.2 No. 235 for global use 2CDC021023S0012 2CDC021038S0012Miniature Circuit Breaker S 200/S 200 M Technical data S 200 S 200 M General Data Standards IEC/EN 60898-1, IEC/EN 60947-2 IEC/EN 60898-1, IEC/EN 60947-2 UL 1077 UL 1077, CSA 22.2 No. 235 Poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Tripping Characteristics B, C, D, K, Z Rated current I 0.5 up to 63 A n Rated frequency 50/60 Hz Rated insulation voltage U 250 V AC (phase to ground), 500 V AC (phase to phase) i Overvoltage Category III Pollution Degree 3 IEC/EN 60898-1 Rated operational voltage U 1P: 230/400 V AC 1P+N: 230 V AC 2P, 3P, 4P: 400 V AC 3P+N: 400 V AC n Max. power frequency recovery voltage U 1P: 253 V AC 1P+N: 253 V AC 2P, 3P, 4P: 440 V AC 3P+N: 440 V AC max 1P: 72 V DC 2P: 125 V DC Min. operating voltage 12 V AC, 12 V DC Rated short-circuit capacity I 6 kA 10 kA cn Energy limiting class (B, C up to 40 A) 3 Rated impulse withstand voltage U (1.2/50 s) 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m) imp Dielectric test voltage 2.0 kV (50/60 Hz, 1 min) Reference temperature for tripping characteristics B, C, D: 30 C Electrical endurance I < 32 A: 20,000 ops. (AC), 1,000 ops. (DC) one cycle 2 s - ON, 13 s - OFF n I 32 A: 10,000 ops. (AC), 1,000 ops. (DC) one cycle 2 s - ON, 28 s - OFF n IEC/EN 60947-2 Rated operational voltage U 1P: 230 V AC 1P+N: 230 V AC 2P, 3P, 4P: 440 V AC 3P+N: 440 V AC e Max. power frequency recovery voltage U 1P: 253 V AC 1P+N: 253 V AC 2P, 3P,4P: 462 V AC 3P+N: 462 V AC max 1P: 72 V DC 2P: 125 V DC Min. operating voltage 12 V AC, 12 V DC Rated ultimate short-circuit breaking capacity I 10 kA 15 kA cu Rated service short-circuit breaking capacity I 7.5 kA 40 A: 11.25 kA cs 50, 63 A: 7.5 kA Rated impulse withstand voltage U (1.2/50 s) 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m) imp Dielectric test voltage 2.0 kV (50/60 Hz, 1 min) Reference temperature for tripping characteristics B, C, D: 55 C K, Z: 20 C Electrical endurance I < 32 A: 20,000 ops. (AC), 1,000 ops. (DC) one cycle 2 s - ON, 13 s - OFF n I 32 A: 10,000 ops. (AC), 1,000 ops. (DC) one cycle 2 s - ON, 28 s - OFF n UL/CSA Rated voltage 1P: 277 V AC, 60 V DC 1P: 277 V AC, 60 V DC 2...4P: 480 Y/277 V AC, 110 V DC 2...4P: 480 Y/277 V AC, 125 V DC Rated interrupting capacity 6 kA (AC), 10 kA (DC) Application Suppl. prot. for general use. Application Codes: TC2, OL0, SC: U1 Reference temperature for tripping characteristic B, C, D, K, Z: 25 C Electrical endurance 6,000 ops. (AC), 6,000 ops. (DC) one cycle 1 s - ON, 9 s - OFF Mechanical data Housing Insulation group II, RAL 7035 Insulation group I, RAL 7035 Toggle Insulation group II, black, sealable Contact position indication Marking on toggle (I ON/0 OFF), Real CPI (red ON/green OFF) 1) Protection degree acc. to EN 60529 IP20 , IP40 in enclosure with cover Mechanical endurance 20,000 ops. Shock resistance acc. to IEC/EN 60068-2-27 25 g, 2 shocks, 13 ms Vibration resistance acc. to IEC/EN 60068-2-6 5 g, 20 cycles at 51505 Hz with load 0.8 I n Environmental conditions acc. to IEC/EN 60068-2-30 28 cycles with 55 C/90-96 % and 25 C/95-100 % Ambient temperature -25 ... +55 C Storage temperature -40 ... +70 C 1) Also fulfilling the requirements acc. to the protection degree IPXXB 2 - 2CDC002157D0202