Safety Light Curtain Approvals: Orion1 Extended Application: For finger and hand detection When the light guard should be close to the hazardous zone When muting or blanking are necessary When several devices should be connected in series (cascading) When space is an issue (no dead zone) Features: Finger and hand detection 7 m and 20 m operating distances (finger and hand detection) Compact dimensions Local reset and EDM Muting and Blanking Cascading No dead zone The Orion1 Extended light curtains are used for finger or hand detection, usually quite close to the dangerous machine, when advanced functions like muting or cascading are necessary. Easy to use Muting sensors are connected directly to the light curtain, with no need for a remote extra muting module. No dead zone: the resolution is guaranteed along the whole length of the light curtain with no need for extra mechanical guard. Cascading with the standard units, no separate slave or master units. Faster installation Alignment help and a wide angle within the limits of a Type 4 device facilitate alignment. M12 connectors speed up cabling. Less downtime Since the alignment level is displayed on the unit, the alignment can be improved before an unwanted stop occurs. Coding protects against mutual interferences. Extensive error indication reduces troubleshooting time. Protective tubes and lens shields protect the devices in harsh environments. Muting: the machine stops when a person Floating blanking: a hand through the goes through but not when the cases go detection zone will stop the machine and through. the moving wire will not.Technical data Functional Safety Data EN ISO 13849-1:2008 PL e, Cat 4 -9 EN 61508-1..4:2010 SIL3 PFH = 2.64 x10 HFT = 1 Mission time = 20 years d EN 62061:2005/A1:2013 SIL CL 3 Power supply +24 VDC 20 % Power consumption Transmitter 3 W max Receiver 5 W max (without load) Outputs 2 PNP Short-circuit protection: 1.4 A max Output current: 0.5 A max / output Output voltage ON: Vdd -1 V min Output voltage OFF: 0.2 V max Capacitive load: 2.2 F at +24 VDC max Current for external lamp 20 mA min 300 mA max Connectors with specific cables Transmitter with M12-C02PT2T: M12-5 pole male connector Receiver with M12-C02PT6RB: M12-12 pole male connector Receiver with M12-C02PT62RM: M12-12 pole male connector + M12-5 pole male connector Cable length (for power supply) 50 m max Light emission ( l ) Infrared, LED (950 nm) Resolution 14 - 30 mm Operating distance 0.220 m for 30 mm 0.27 m for 14 mm Ambient light rejection According to IEC-61496-2:2013 Operating temperature 0+ 50 C Storage temperature - 25+ 70 C Humidity range 1595 % (no condensation) Protection class IP65 (EN 60529:2000) Weight 1.35 kg / meter for each single unit Housing material Painted aluminium (yellow RAL 1003) Front side material PMMA Cap material PBT Valox 508 Function settings at delivery The functions are configured with push-buttons on the units. No code Muting EDM enabled Automatic Reset T/X muting 10 min muting time-out Override trigger = level Long range * Two specific cables must be ordered with Orion1 Extended, one for the transmitter and one for the receiver. See next page.