Safety Light Grid Approvals: Orion3 Base Application: For body detection When power is available on only one side. When a sturdy profile is ne- cessary. Features: Body detection, 2 to 4 beams Active and passive unit Up to 8 m operating distance Sturdy profile Local reset and EDM Type 4 The Orion3 Base light grids are used for body detection, usually for access protection. Transmitter and receiver are both in the same active unit. The beams are reflected by the passive unit. Only the active unit needs to be supplied. Easy to use No more functions or settings than necessary. A local reset button can be connected directly to the light grid: no need for cable between the reset button and the electrical cabinet or for an extra control module. Each light grid can monitor the actuators without any extra control module (EDM function). Faster installation Less cabling: only the active unit has to be connected. Alignment help and a wide angle within the limits of a Type 4 device facilitate alignment. Rotation brackets simplify alignment too. M12 connectors speed up cabling. Less downtime Since the alignment level is displayed on the unit, the alignment can be improved before an unwanted stop occurs. Extensive error indication reduces troubleshooting time. Only the active unit needs cabling, which saves cable length and installation time.Technical data Functional Safety Data EN ISO 13849-1:2008 PL e, Cat 4 -9 EN 61508-1..4:2010 SIL3 PFH = 9.28 x10 HFT = 1 Mission time = 20 years d EN 62061:2005/A1:2013 SIL CL 3 Power supply +24 VDC 20 % Consumption, Active unit 6.5 W max (without load) Outputs 2 PNP Short-circuit protection: 1.4 A at 55C Output current: 0.5 A max / output Output voltage ON: Power supply value less 1 V (min.) Output voltage OFF: 0.2 V max Capacitive load: 2.2 F at +24 VDC max Connectors M12 - 8 pole male connector Cable length (for power supply) 70 m max Light source Infrared, LED (950 nm) Resolution 319,75 - 519,75 mm Operating distance 0.5...8 m except K2C-090: 0.5..6 m Ambient light rejection According to IEC-61496-2:2013 Operating temperature 0+ 55 C Storage temperature - 25+ 70 C Humidity range 1595 % (no condensation) Protection class IP 65 (EN 60529:2000) Weight Orion3-4-K1C-050-B 1.3 Kg Orion3-4-K2C-080-B 1.8 Kg Orion3-4-K2C-090-B 2.1 Kg Orion3-4-K2C-120-B 2.6 Kg Orion3-4-M1C-050 (passive) 1.2 Kg Orion3-4-M2C-080 (passive) 1.7 Kg Orion3-4-M2C-090 (passive) 1.9 Kg Orion3-4-M2C-120 (passive) 2.5 Kg Housing material Painted aluminium (yellow RAL 1003) Front glass material PMMA Cap material PBT Valox 508 Connection Active unit* White (1)** Reset/Acknowledge/Reset mode - Must be connected for the light guard to function, either to + 24 VDC for Automatic Reset or to 0 V for Manual Reset. Brown (2) + 24 VDC Green (3)** EDM selection- must be connected to +24 VDC to deactivate EDM Yellow (4) EDM Grey (5) OSSD1 Pink (6) OSSD2 Blue (7) 0 V Red (8) Earth * Colors according to ABB Jokab Safety standard cables ** The RESET/ACKNOWLEDGE/RESET MODE wire and the supply wires MUST be connected in order for the device to function. The other wires may be floating.