GECA40 40 Watt Series Commercial Wide-Range Input 2 Year Warranty Wide-Range AC Input 90-264 VAC Industry Standard Footprint - 3x 5x 1.25 Conducted EMI Exceeds FCC Class B and CISPR 22 Class B Single and Multiple Outputs Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03, IEC and EN60950-1 CB Report Available RoHS Compliant Marked to LVD Unless otherwise noted, all parameters are nominal values measured at 120 VAC 25C and 0-95% Specifications relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory. AC Input Output Noise Universal Input 90-264 VAC, 47-63 Hz single phase. 0.5% rms, 1% pk-pk typical (see chart), 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the Input Current power supply with load terminated with 0.1 F capacitor. Maximum input current at 120 VAC, 60 Hz with full rated output load: Multiple models 1.7 A, Single models 1.0 A. TransientResponse Main output500 s typical response time for return to within 0.5% of Hold-Up Time final value for a 50% load step change. i/ t<0.2 A/s. Maximum voltage 10 ms minimum with 40 W load, nominal line (120 VAC). deviation is 3.5%. Startup/ shutdown overshoot less than 3%. OutputPower SwitchingFrequency 40 W continuous, 45 W peak. Peak ratings are for 60 s maximum duration, 70 kHz +/-10 kHz. 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. VoltageAdjustment Provided on V1. Adjustable voltages are preset at factory. Outputs are OverloadProtection capable of minimum +/- 5% change from nominal setting. Multiple output Fully protected against short circuit and output overload. Short circuit models - V2 voltage will track V1 adjustment. protection is cycling type power limit on V1 and V2, foldback type on V3. EMI/EMC Compliance Overvoltage Protection All models include built-in EMI filtering to meet the following emissions On V1 is 120% to 160%. See chart. requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL 75 to 80% at full rated load, nominal input voltage, depending on model and load distribution. Conducted Emissions EN55022 Class B FCC Class B Static Discharge EN61000-4-2, Level 3 Turn-on Time RF Field Susceptibility EN61000-4-3, Level 3 Less than 2 seconds. Fast Transients/Bursts EN61000-4-4, Level 3 InputProtection Surge Susceptibility EN61000-4-5, Level 3 Internal AC fuse provided. Designed to blow only if a catastrophic failure Safety Approvals occurs in the unit. Fuse does not blow on overload or short circuit. SL Power Electronics, Corp. declares under our sole responsibility Inrush Current that all GECA models are in conformity with the applicable requirements of Inrush is limited by internal thermistors. Inrush at 240 VAC under cold EN60950 following the provisions of the Low Voltage Directive 73/23/EEC. start conditions will not exceed 37A. All GECA models are approved to UL60950-1: 2003, TemperatureCoefficient CSA-22.2 No. 60950-1-03, IEC and EN60950-1 0.03%/C typical on all outputs. MTBF TemperatureRange 120kHrs. Designed for 0 to 45C operation at full rated output power derate output current and total output power by 2.5% per C above 45C. SL Power Electronics, Corp. 6050 King Drive Ventura CA, 93003 Phone:805.486.4565 Fax:805.487.8911 Email:info slpower.com www.slpower.comGECA40 40 Watt Series Commercial Wide-Range Input Commercial Output Output Current Current Line Load V1 OVP Ripple & Model No. (V) Minimum Maximum Regulation Regulation Set Point Noise(P-P) GECA40AG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV V2 +12 V 0 A 2 A +/-1% +/-10% 120 mV V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV GECA40BG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV V2 +12V 0 A 2 A +/-1% +/-10% 120 mV V3 -5 V 0 A 0.3 A +/-1% +/-5% 50 mV GECA40HG V1 +3.3 V 0.4 A 4 A +/-0.5% +/-3% 4.4 +/-0.6 V 50 mV V2 +12 V 0 A 2 A +/-1% +/-10% 120 mV V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV GECA40DG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV V2 +24 V 0 A 1.2 A +/-1% +/-10% 240 mV V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV GECA40-5G V1 5 V 0 A 7 A +/-0.5% +/-3% 7.0 +/-1.0 V 50 mV GECA40-12G V1 12 V 0 A 3.3 A +/-0.5% +/-3% 16.8 +/-2.4 V 120 mV GECA40-15G V1 15 V 0 A 2.7 A +/-0.5% +/-3% 21.0 +/-3.0 V 150 mV GECA40-24G V1 24 V 0 A 1.7 A +/-0.5% +/-3% 33.6 +/-4.8 V 240 mV Environmental Specifications GECA40 SeriesMechanical Specifications ENVIRONMENT OPERATING NON-OPERATING CON 1: MOLEX P/N 26-60-4030, w/center PIN Removed Temperature (A) 0 to 45C -40 to +85C 0.156 3.96 mm CTR Header Humidity (A) 20 to 90% RH 10 to 95% RH Shock (B) 20 g 40 g CON 2: pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft MOLEX P/N 26-60-4060, 0.156 3.96 mm CTR Header 2 2 Vibration (C) 1.5 g 0.0032 g /Hz 5 g 0.026 g /Hz rms rms Input J1 A. Units should be allowed to warm up/operate under non-condensing PIN 1) AC Line conditions before application of power. PIN 3) AC Neutral B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, OutputJ2 3 orthogonal axes, total 6 shocks. Multiple Output SingleOutput C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to Models Models 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and PIN 1) Output 2 Output 1 1 hr./axis non-operating. PIN 2) Common Output 1 PIN 3) Common Output 1 PIN 4) Output 1 Common PIN 5) Output 1 Common PIN 6) Output 3 Common Mating Connector HousingP/N Contacts P/N MOLEX Input 09-50-3031 08-52-0072 Output 09-50-3061 08-52-0072 Note: 5A maximum recommended current per Connector PIN Weight 1.0 lbs Max 0.45 kg Max. Tolerance X.XX=0.030 X.XXX=0.010 0.mm SL Power Electronics, Corp. 6050 King Drive Ventura CA, 93003 Phone:805.486.4565 Fax:805.487.8911 Email:info slpower.com www.slpower.com Data Sheet 2006 SL Power Electronics, Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. Rev.8/30/06