Data Sheet GE CLP0112 Open Frame Power Supply 90 - 265Vac input 12Vdc output 150W Output Power Features Compact size 50.8 mm x 101.6 mm x 36.1 mm 3 (2 in x 4 in x 1.4 in) with density of 13.4W/in Universal AC Input Range (90 265VAC) Output voltage of 12V (adjustable -2.5/+5%) Maximum output current of 12.5A 12Vout (150W) High efficiency Full load capability at 75C and 1m/s (200LFM) airflow with derating at higher temperatures or lower airflows When used inside sealed enclosure, can deliver 130W 55C outside ambient temperature Output overcurrent protection (non-latching) Overtemperature protection Output overvoltage protection Up to 11ms of holdup time Active power factor corrected input Applications Conducted EMI - meets CISPR22 (EN55032) and FCC Class B requirements Telecommunications equipment Meets IEC61000-4-5, Level 4 (2kV/4kV) Embedded Computing Compliant to RoHS Directive 2011/65/EU and amended Storage Systems Directive (EU) 2015/863 Industrial equipment Compliant to REACH Directive (EC) No 1907/2006 1mil Conformal coated Z02A version passed Salt/Fog test and Mixed Flow Gas test Fuse in Neutral line in Z03A version for Japan market UL and cUL approved to UL/CSA62368-1, TUV (EN62368- 1), CE Mark (for LVD) and CB Report available ISO** 9001 and ISO 14001 certified manufacturing facilities Description In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0112 open frame power supply delivers greater than 90 percent typical power efficiency and full load output at 75C. W i t h i t s s m a l l s i z e , t he CLP series is specifically designed to handle power challenges associated with tight space and low airflow. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits. Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards 11/6/2020 2017 General Electric Company. All rights reserved. Data Sheet GE CLP0112 Open Frame Power Supply 90 - 265Vac input 12Vdc output 150W Output Power Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 265 Vac For up to 10 seconds max. All 90 275 Vac Operating Ambient Temperature All -40 85 C (see Thermal Considerations section) (in sealed enclosure applications with thermally conductive pad to All -40 55 C enclosure, P = 130W) O,max Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Isolation Voltage Input to output All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 50 Vac Ambient temperature outside the sealed enclosure containing the power supply. Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 265 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (V = 90Vac) All 3 A IN RMS Input Power Factor (115VAC or 230VAC in at full load) All 0.95 Inrush Transient Current (V = 265Vac, T = 25C) All 100 A Peak IN amb Leakage Current to earth ground (V = 265Vac) All 2 mA IN Output Voltage Setpoint All 12 Vdc Output Voltage Tolerance (due to set point, temperature variations, load All -3 3 % and line regulation) Output Voltage Adjustment Range All 11.7 12.6 Vdc Output Load Regulation All 1 %Vout Output Line Regulation All 0.5 %Vout Output Ripple and Noise measured with 0.1F ceramic capacitor in 1 parallel with 10F tantalum capacitor, at 25C All 180 mV p-p Peak-to-peak (20MHz Bandwidth) Dynamic Load Response 50% to 75% load transient, 0.1A/s slew rate. Output voltage deviation All 5% % Settling Time All 500 s Output Current All 0 12.5 Adc Output Current Limit Inception All 110 145 % IO,max Maximum Output Capacitance All 5000 F Efficiency at 25C: VIN = 230Vac, 20% load All 89.3 % 50% load All 92.9 % 100% load All 92.7 % V = 115Vac, 20% load All 87.7 % IN 50% load 90.9 % All 100% load 90.5 % All 2 Holdup Time VIN = 115Vac or 230Vac, 100% load All 11 ms 1 Below -25C, ripple may exceed the specified level. Specification will be met after warm up period of 15s. 2 Holdup time may be lower at cold temperatures 11/6/2020 2017 General Electric Company. All rights reserved. Page 2