Datasheet CLP0205 Open Frame Power Supply 90 - 265Vac input 5Vdc output 200W Output Power Features Compact size 50.8mm x 101.6mm x 36.1mm 3 (2in x 4in x 1.4in) with density of 18W/in Universal AC Input Range (90 265VAC) Output voltage of 5V (adjustable 4.5V to 5.2V) Active current sharing Standby output of 12V 0.1A Maximum output current of 40A 5Vout (200W) High efficiency Full load capability at 50C and 1m/s airflow with derating at higher temperatures or lower airflows Capable of 135 W out in sealed enclosure applications with enclosure ambient at 55C Output overcurrent protection (non-latching) Overtemperature protection Output overvoltage protection Applications Minimum of 11ms of holdup time at 200W out Active power factor corrected input Industrial equipment Conducted EMI - meets CISPR32 (EN55032) and FCC Class LED Signage B requirements Telecommunications equipment Compliant to RoHS (recast) EU Directive 2011/65/EC and amended Directive (EU) 2015/863 Compliant to REACH Directive (EC) No 1907/2006 UL and cUL approved to UL/CSA62368-1, TUV (EN62368- 1), CE Mark (for LVD) and CB Report available ISO** 9001 and ISO 14001 certified manufacturing facilities Description In a small 2 x 4 inch footprint, the 5Vdc single-output CLP0205 open frame power supply delivers greater than 90 percent typical power efficiency and full load output at 50C and 1m/s airflow. Protection features include output overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). This power supply supports active current sharing with a similar unit. Leads and covers are available as accessories. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. ** ISO is a registered trademark of the International Organization of Standards 2018 ABB Limited. All rights reserved. Data Sheet CLP0205 Open Frame Power Supply 90 - 265Vac input 5Vdc output 200W Output Power Absolute Maximum Ratings Stresses over the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions over those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 265 Vac For up to 10 seconds All 90 275 Vac Operating Ambient Temperature All -40 70 C (see Thermal Considerations section) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m All Isolation Voltage Input to output 3000 Vac All Input to safety ground 1500 Vac All Outputs to safety ground 50 Vac Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 265 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (V = 90Vac) All 2.7 A IN RMS Input Power Factor (230Vac, Full Load) All 0.95 Inrush Transient Current (V = 265Vac, T = 25C) All 100 A Peak IN amb Leakage Current to earth ground (V = 265Vac) All 3.5 mA IN Output Voltage Setpoint All 5 Vdc Output Voltage Tolerance (due to set point, temperature variations, load All -2 2 % and line regulation) Output Voltage Adjustment Range All 4.5 5.2 Vdc Output Remote Sense Range All 250 mVdc Output Load Regulation All 1 %Vout Output Line Regulation All 0.25 %Vout Output Ripple and Noise measured with 0.1F ceramic capacitor in parallel with 10F electrolytic capacitor All 100 mV p-p Peak-to-peak (20MHz Bandwidth) Dynamic Load Response 50% to 100% load transient, 1A/s slew rate Output voltage deviation All 250 mV Settling Time All 500 s Output Current All 0 40 Adc Output Current Limit Inception All 105 145 % I O,max Maximum Output Capacitance All 5000 F Standby Output Voltage (regulation is +/-2%) All 12.0 Vdc Standby Output Current All 0.1 Adc Efficiency: VIN = 230Vac, 20% load All 85 % 50% load All 90 % 100% load All 91.5 % V = 115Vac, 20% load All 87 % IN 50% load All 90.5 % 100% load All 90 % 1 Holdup Time V = 115Vac, 200W load All 11 ms IN V = 230Vac, 200W load All 11 ms IN 1 Holdup time may be lower at temperatures below -25C 2018 ABB Limited. All rights reserved. Page 2