Data Sheet GE CLP0212 Open Frame Power Supply 90 - 264Vac input 12Vdc output 200W Output Power Features Compact size 50.8 mm x 101.6 mm x 36.1 mm 3 (2 in x 4 in x 1.4 in) with density of 18W/in Universal AC Input Range (90 264VAC) Output voltage of 12V (adjustable 5%) Maximum output current of 16.7A 12Vout (200W) Standby output of 5V or 3.3V 0.25A High efficiency with 80 PLUS Gold Certification Full load capability at 50C and 1m/s (200LFM) airflow with derating at higher temperatures or lower airflows Remote ON/OFF Output overcurrent protection (non-latching) Overtemperature protection Output overvoltage protection Up to 12ms of holdup time Parallellable with current sharing Active power factor corrected input Applications Conducted EMI - meets CISPR22 (EN55022) and FCC Telecommunications equipment Class A requirements Embedded Computing Compliant to RoHS EU Directive 2002/95/EC Storage Systems UL and cUL approved to UL/CSA60950-1, TUV (EN60950-1), CE Mark (for LVD) and CB Report available Industrial equipment ISO** 9001 and ISO 14001 certified manufacturing facilities Description In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy efficiency. With its small size, t he CLP series is specifically designed to handle power challenges associated with tight 3 space and low airflow. Offering a leading 18W/in power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from communications, computing and data storage original equipment manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50C (122F) with higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits. Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards December 3, 2015 2012 General Electric Company. All rights reserved. Data Sheet GE CLP0212 Open Frame Power Supply 90 - 264Vac input 12Vdc output 200W Output Power Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 264 Vac For up to 10 seconds max. All 90 275 Vac Operating Ambient Temperature All -25 70 C (see Thermal Considerations section) CLP0212FPEX5Z01A, C -40 85* C CLP0212FPEX5Z02A -40 85* C CLP0212FPEX5Z03A, C (in sealed enclosure applications with thermally conductive pad to CLP0212FPEX5Z02A -40 55 C enclosure, PO,max = 65W) (in sealed enclosure applications with thermally conductive pad to CLP0212FPEX5Z03A, C -40 55 C enclosure, PO,max = 110W) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Startup at -40C is limited to 80% of maximum load (160W) for all versions, except the CLP0212FPEX5Z02A which can start up at full load. * Unit is capable of operation up to 85C ambient for brief periods of time provided humidity is kept below 40%. Sustained operation at 85C when input voltage is above 230VAC and output power loading is at or near the maximum rated value can degrade reliability of the product. Ambient temperature outside the sealed enclosure containing the power supply. Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 264 Vac Input Source Frequency All 47 50/60 63 Hz All versions except Input Current (VIN = 90Vac) 4 ARMS CLP0212FPEX5Z02A CLP0212FPEX5Z02A 1.6 ARMS Input Power Factor All 0.95 Inrush Transient Current (V = 264Vac, T = 25C) All 100 A Peak IN amb Leakage Current to earth ground (V = 264Vac) All 2 mA IN Output Voltage Setpoint All 12 Vdc Output Voltage Tolerance (due to set point, temperature variations, All -2 2 % load and line regulation) Output Voltage Adjustment Range All 11.4 12.6 Vdc Output Remote Sense Range All 250 mVdc Output Load Regulation All 1.5 %Vout Output Line Regulation All 0.5 %Vout Output Ripple and Noise measured with 0.1F ceramic capacitor in 1 parallel with 10F tantalum capacitor, at 25C All 180 mV p-p Peak-to-peak (20MHz Bandwidth) Dynamic Load Response 50% to 75% load transient, 0.1A/s slew rate Output voltage deviation All 5% % Settling Time All 500 s All versions except Output Current 0 16.7 Adc CLP0212FPEX5Z02A Output Current CLP0212FPEX5Z02A 0 8.34 Adc Output Current Limit Inception All 115 % IO,max 1 Output ripple is 300mV p-p maximum at -40C. To reduce further, additional external capacitance needed. December 3, 2015 2012 General Electric Company. All rights reserved. Page 2