Data Sheet GE CLP0224 Open Frame Power Supply 90 - 264Vac input 24Vdc output 200W Output Power Features Compact size 50.8 mm x 101.6 mm x 37.25 mm 3 (2 in x 4 in x 1.47 in) with density of 18 W/in Universal AC Input Range (90 264VAC) Output voltage of 24V (adjustable 5%) Maximum output current of 8.3A 24Vout (200W) High efficiency (93% at Full Load, 230VAC in) Full load capability at 50C and 1m/s airflow with derating at higher temperatures or lower airflows Output overcurrent protection (non-latching) Overtemperature protection Output overvoltage protection Up to 11ms of holdup time at 200W out Active power factor corrected input Conducted EMI - meets CISPR22 (EN55022) and FCC Class B requirements Applications Compliant to RoHS II EU Directive 2011/65/EU Industrial equipment UL and cUL approved to UL/CSA60950-1, TUV Telecommunications equipment (EN60950-1), CE Mark (for LVD) and CB Report available ISO** 9001 and ISO 14001 certified manufacturing facilities Description In a small 2 x 4 inch footprint, the 24Vdc single-output CLP0224 open frame power supply delivers greater than 90 percent typical power efficiency and full load output at +50C. Wi t h i t s s m a l l s i z e , t he CLP series is specifically designed to handle 3 power challenges associated with tight space and low airflow. Offering a leading 18W/in power density in a 1U high, fan- less form factor, the CLP series addresses a broad range of applications in new products from industrial equipment and communications original equipment manufacturers (OEMs). Higher temperature operation is possible at derated output. The CLP series utilizes a unique design approach at this power level, leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits. Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards February 14, 2017 2017 General Electric Corporation. All rights reserved. Data Sheet GE CLP0224 Open Frame Power Supply 90 - 264Vac input 24Vdc output 200W Output Power Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 264 Vac Operating Ambient Temperature All -40 85 C (see Thermal Considerations section) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Isolation Voltage Input to output All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 50 Vac Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 264 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (VIN = 90Vac) All 4 ARMS Input Power Factor (115VAC or 230VAC in at full load) All except ..Z02A 0.95 ..Z02A 0.92 Inrush Transient Current (V = 264Vac, T = 25C) All 100 A Peak IN amb Leakage Current to earth ground (V = 264Vac) All 2 mA IN Output Voltage Setpoint All 24 Vdc Output Voltage Tolerance (due to set point, temperature variations, All -3 3 % load and line regulation) Output Voltage Adjustment Range All 22.8 25.2 Vdc Output Load Regulation All 1 %Vout Output Line Regulation All 0.5 %Vout Output Ripple and Noise measured with 0.1F ceramic capacitor in 1 parallel with 10F electrolytic capacitor, at 25C All 360 mV p-p Peak-to-peak (20MHz Bandwidth) Dynamic Load Response 50% to 100% load transient, 1A/s slew rate Output voltage deviation All 5% % Settling Time All 500 s Output Current All except ..Z02A 0 8.33 Adc ..Z02A 0 6.25 Adc Output Current Limit Inception All 110 160 % I O,max Maximum Output Capacitance All 3000 F Efficiency at 25C: V = 230Vac, 20% load All except ..Z02A 88.1 % IN 50% load All except ..Z02A 92.7 % 100% load All except ..Z02A 93.1 % VIN = 115Vac, 20% load All except ..Z02A 88.6 % 50% load All except ..Z02A 91.5 % 100% load All except ..Z02A 90.8 % 1 Below -25C, output ripple may exceed the specified level. Specification will be met after warm up period of 15s. February 14, 2017 2017 General Electric Corporation. All rights reserved. Page 2