DATASHEET CLP0248 Open Frame Power Supply 90 - 265Vac Input 48V/4.16A or 54V/3.7A Output 200W Output Power . Description Applications include: Industrial Equipment Telecommunications Equipment SG Pico Base-Stations Features Compact size 50.8 mm x 101.6 mm (2 in x 4 in x 1.40 in) Supports paralleling with active current sharing, as long as with density of 18 W/in3 OR-ing components are added Universal AC Input Range (90 ~ 265VAC permanently, IEC61000-4-5, Level 4 (2kV/4kV) 350VAC for 5 minutes) Output overcurrent protection (non-latching) Output voltage of 48V or 54V with 3V adjustable voltage Overtemperature and output over-voltage protections Standby output of 5V/1A (5W) Up to 11ms of holdup time at 200W out (with Vout at 42V Standby power consumption of 0.5W (with no load on the at the end) standby output, and the main output inhibited) Active power factor corrected input High efficiency (88% at Full Load, 230VAC in, 25 ) Conducted EMI - meets CISPR22 (EN55022) and FCC Class Full load capability at 50 and 1m/s airflow with derating B requirements at higher temperatures or lower airflows Compliant to RoHS2 EU Directive 2011/65/EU Capable of >140W output in sealed enclosure applications, UL and cUL approved to UL/CSA60950-1, TUV (EN60950- with enclosure ambient at 55 , and an enclosure internal 1), CE Mark (for LVD) and CB Report available temperature of 85 ISO** 9001 and ISO 14001 certified manufacturing facilities PoE compliant, output to Earth isolation of 2250Vdc See footnotes on page 4 Page 1 2020 ABB. All rights reserved. Technical Specifications Absolute Maximum Ratings Stresses over the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions over those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous Operation All 90 265 Vac For up to 10 seconds operation All 90 275 Vac For up to 5 minutes, may not operate, no damage All 305 Vac Operating Ambient Temperature All -40 85 C (see Thermal Considerations section) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Isolation VoltageInput to output All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 2250 Vac Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 265 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (V = 90Vac) All 2.7 A IN RMS Input Power Factor (230Vac, Full Load) All 0.95 Inrush Transient Current (V = 265Vac, T = 25C) All 100 A Peak IN amb Leakage Current to earth ground (V = 265Vac) All 3.5 mA IN Output Voltage Adjustment Range All 11.4 12.6 Vdc Output Voltage Setpoint 201A 48 Vdc 202A 54 Vdc Output Voltage Tolerance (due to set point, temperature variations, load All -2 2 % and line regulation) Output Voltage Adjustment Range 201A 45 51 Vdc 202A 51 57 Vdc Output Remote Sense RangeTotal All 1 Vdc Output Load Regulation All 1 %Vout Output Line Regulation All 0.25 %Vout Output Ripple and Noise measured with 0.1F and 10F capacitors in parallel. Peak-to-peak (20MHz Bandwidth) (higher for the 54V 201A 500 mV p-p unit) 202A 550 mV p-p Dynamic Load Response 50% to 100% load transient, 1/s slew rate Output voltage deviation All 2.4 V Settling Time All 2 Ms Output Current 201A 0 4.16 Adc 202A 0 3.7 Adc Output Current Limit Inception All 105 140 % I O,max Output Current Capacitance All 1000 F -continued on next page- See footnotes on page 4 Page 2 2020 ABB. All rights reserved.